On-Line Fission Gas Release Monitoring System in the High Flux Reactor Petten

被引:0
|
作者
Laurie, M. [1 ]
Fuetterer, M. A. [1 ]
Appelman, K. H. [1 ]
Lapetite, J. -M. [1 ]
Marmier, A. [1 ]
Knol, S. [1 ]
Best, J. [1 ]
机构
[1] European Commiss Joint Res Ctr, Inst Transuranium Elements, Postfach 2340, D-76125 Karlsruhe, Germany
关键词
Fission Product release; Fuel testing; Gamma spectrometry; High Flux Reactor; HTR; IRRADIATION; FUEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For HTR fuel irradiation tests in the HFR Petten a specific installation was designed and installed dubbed the "Sweep Loop Facility" (SLF). The SLF is tasked with three functions, namely temperature control by gas mixture technique, surveillance of safety parameters (temperature, pressure, radioactivity etc.) and analysis of fission gas release for three individual capsules in two separate experimental rigs. The SLF enables continuous and independent surveillance of all gas circuits. The release of volatile fission products (FP) from the in-pile experiments is monitored by continuous gas purging. The fractional release of these FP, defined as the ratio between release rate of a gaseous fission isotope (measured) to its instantaneous birth rate (calculated), is a licensing-relevant test for HTR fuel. The developed gamma spectrometry station allows for higher measurement frequencies, thus enabling follow-up of rapid and massive release transients. The designed stand-alone system was tested and fully used through the final irradiation period of the HFR-EU1 experiment which was terminated on 18 February 2010. Its robustness allowed the set up to be used as extra safety instrumentation. This paper describes the gas activity measurement technique based on HPGe gamma spectrometry and illustrates how qualitative and quantitative analysis of volatile FP can be performed on-line.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Development and Validation of DNBR On-line Monitoring System for HPR1000 Reactor
    Chen X.
    Wu Q.
    Deng J.
    Liu Y.
    Ren C.
    Wang X.
    Peng H.
    Hedongli Gongcheng/Nuclear Power Engineering, 2024, 45 (02): : 248 - 253
  • [42] On-line Monitoring System with LoRaWAN
    Penkov, St.
    Taneva, A.
    Petrov, M.
    IFAC PAPERSONLINE, 2019, 52 (25): : 533 - 538
  • [43] On-line Monitoring System for Tracks
    Meixedo, Andreia
    Goncalves, Andre
    Calcada, Rui
    Gabriel, Joaquim
    Fonseca, Helder
    Martins, Rodolfo
    PROCEEDINGS OF 2015 3RD EXPERIMENT AT INTERNATIONAL CONFERENCE (EXP AT'15), 2015, : 133 - +
  • [44] ON-LINE PATIENT MONITORING SYSTEM
    BEAUMONT, JO
    DATAMATION, 1969, 15 (05): : 50 - &
  • [45] Gas Transport of Fission Products from a Target Near the Core of a High-Flux Reactor
    Simonovski, D.
    Novikov, Yu. N.
    Gusev, Yu. I.
    Chenmarev, S. V.
    ATOMIC ENERGY, 2019, 125 (06) : 384 - 390
  • [46] Gas Transport of Fission Products from a Target Near the Core of a High-Flux Reactor
    D. Simonovski
    Yu. N. Novikov
    Yu. I. Gusev
    S. V. Chenmarev
    Atomic Energy, 2019, 125 : 384 - 390
  • [47] Development of an on-line partial discharge monitoring system for gas insulated substations
    Sakakibara, T
    Murase, H
    Haginomori, E
    Wakabayashi, S
    Emoto, K
    Ogawa, A
    ELECTRICAL ENGINEERING IN JAPAN, 1999, 129 (02) : 40 - 50
  • [48] The application analysis of the on-line monitoring system of dissolved gas in transformer oil
    Li Yanming
    Liu Gang
    Liang Ying
    Xing Yan
    2007 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2007, : 747 - +
  • [49] Configuration design improvement of on-line flue gas emission monitoring system
    Wang, Yuan-Jing
    Lu, Ji-Dong
    Mo, Chao
    Zhongguo Dianli/Electric Power, 2002, 35 (11):
  • [50] Research on flue gas on-line monitoring system for Thermal Power Plant
    Wang, Jing
    Hou, Jie
    Proceedings of the 30th Chinese Control Conference, CCC 2011, 2011, : 4453 - 4456