On-Line Fission Gas Release Monitoring System in the High Flux Reactor Petten

被引:0
|
作者
Laurie, M. [1 ]
Fuetterer, M. A. [1 ]
Appelman, K. H. [1 ]
Lapetite, J. -M. [1 ]
Marmier, A. [1 ]
Knol, S. [1 ]
Best, J. [1 ]
机构
[1] European Commiss Joint Res Ctr, Inst Transuranium Elements, Postfach 2340, D-76125 Karlsruhe, Germany
关键词
Fission Product release; Fuel testing; Gamma spectrometry; High Flux Reactor; HTR; IRRADIATION; FUEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For HTR fuel irradiation tests in the HFR Petten a specific installation was designed and installed dubbed the "Sweep Loop Facility" (SLF). The SLF is tasked with three functions, namely temperature control by gas mixture technique, surveillance of safety parameters (temperature, pressure, radioactivity etc.) and analysis of fission gas release for three individual capsules in two separate experimental rigs. The SLF enables continuous and independent surveillance of all gas circuits. The release of volatile fission products (FP) from the in-pile experiments is monitored by continuous gas purging. The fractional release of these FP, defined as the ratio between release rate of a gaseous fission isotope (measured) to its instantaneous birth rate (calculated), is a licensing-relevant test for HTR fuel. The developed gamma spectrometry station allows for higher measurement frequencies, thus enabling follow-up of rapid and massive release transients. The designed stand-alone system was tested and fully used through the final irradiation period of the HFR-EU1 experiment which was terminated on 18 February 2010. Its robustness allowed the set up to be used as extra safety instrumentation. This paper describes the gas activity measurement technique based on HPGe gamma spectrometry and illustrates how qualitative and quantitative analysis of volatile FP can be performed on-line.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] JRC's on-line fission gas release monitoring system in the high flux reactor Petten
    Laurie, M.
    Futterer, M. A.
    Appelman, K. H.
    Lapetite, J. M.
    Marmier, A.
    Berg, G.
    NUCLEAR ENGINEERING AND DESIGN, 2012, 251 : 325 - 329
  • [3] Fuel management at the Petten High Flux Reactor
    Thijssen, PJM
    RRFM'99: 3RD INTERNATIONAL TOPICAL MEETING ON RESEARCH REACTOR FUEL MANAGEMENT, 1999, : 78 - 82
  • [4] Testing of research reactor fuel in the high flux reactor (Petten)
    Guidez, J
    Markgraf, JW
    Sordon, G
    Wijtsma, FJ
    Thijssen, PJM
    Hendriks, JA
    RRFM'99: 3RD INTERNATIONAL TOPICAL MEETING ON RESEARCH REACTOR FUEL MANAGEMENT, 1999, : 25 - 29
  • [5] Neutron diffraction facilities at the high flux reactor, Petten
    Ohms, C
    Youtsos, AG
    Bontenbal, A
    Mulder, FM
    PHYSICA B, 2000, 276 : 160 - 161
  • [6] UPGRADING AND MODERNIZATION OF THE HIGH-FLUX REACTOR PETTEN
    AHLF, J
    SCHINKEL, J
    NUCLEAR ENGINEERING AND DESIGN, 1992, 137 (01) : 49 - 56
  • [7] THE HIGH-FLUX REACTOR PETTEN FACILITY AND PROGRAM
    AHLF, J
    ATOMWIRTSCHAFT-ATOMTECHNIK, 1993, 38 (05): : 346 - 350
  • [8] Analysis of Fission Gas Release Kinetics by On-Line Mass Spectrometry
    Zerega, Yves
    Reynard-Carette, Christelle
    Parrat, Daniel
    Carette, Michel
    Brkic, Boris
    Lyoussi, Abdallah
    Bignan, Gill
    Janulyte, Aurika
    Andre, Jacques
    Pontillon, Yves
    Ducros, Gerard
    Taylor, Steve
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1323 - 1334
  • [9] Development of gas flow reactor with on-line monitoring system for nitrogen dioxide removal
    Chaisiwamongkhol, Korbua
    Manoyen, Noppadon
    Suttiponparnit, Mkrit
    Nacapricha, Duangjai
    Smith, Siwaporn Mejoo
    Uraisin, Kanchana
    MICROCHEMICAL JOURNAL, 2017, 135 : 199 - 206
  • [10] New Temperature Monitoring Devices for High-Temperature Irradiation Experiments in the High Flux Reactor Petten
    Laurie, M.
    Fuetterer, M. A.
    Lapetite, J. M.
    Fourrez, S.
    Morice, R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (05) : 2319 - 2324