Study on the tracks in a nuclear track detector (CR39) for detection of laser-induced charged particles

被引:9
|
作者
Lee, Ji Young [1 ]
Jo, Jae Heung
Park, Seong Hee
Lee, Kitae
Lee, Yong Woo
Yea, Kwon-Hae
Cha, Yong Ho
Jeong, Young Uk
机构
[1] Hannam Univ, Dept Appl Opt & Electromagnet, Taejon 306791, South Korea
[2] Korea Atom Energy Res Inst, Quantum Opt Div, Taejon 305600, South Korea
关键词
nuclear track detector; CR39; track etch rate; bulk etch rate;
D O I
10.3938/jkps.51.426
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Experiments on laser-induced charged particle generation are now well under way by using an ultrashot, intense Ti:sapphire laser developed at KAERI (Korea Atomic Energy Researc Institute)For the measurements of protons and light ions generated, TASTRAK (CR39) plastic of 0.75 mm in thickness, manufactured by T rack Analysis Systems Ltd. at Bristol University, was used as a nuclear track detector. We investigated the dependence of track development on the energy of the laser-induced charged particles and the etching conditions. We use the measured bulk etching rate to present the optimal etching conditions for the experiments on laser-accelerated proton generation by using a 10-TW laser system.
引用
收藏
页码:426 / 430
页数:5
相关论文
共 50 条
  • [41] A study of the effect of gamma and laser irradiation on the thermal, optical and structural properties of CR-39 nuclear track detector
    Nouh, SA
    Atta, MR
    El-Melleegy, WM
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2004, 159 (8-9): : 461 - 474
  • [42] Study etching characteristics of a track detector CR-39 with ultraviolet laser irradiation
    Dwaikat, Nidal
    Iida, Toshiyuki
    Sato, Fuminobu
    Kato, Yushi
    Ishikawa, Ippei
    Kada, Wataru
    Kishi, Atsuya
    Sakai, Makoto
    Ihara, Yohei
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (02): : 826 - 830
  • [43] Detection threshold control of CR-39 plastic nuclear track detectors for the selective measurement of high LET secondary charged particles
    Kodaira, S.
    Yasuda, N.
    Kawashima, H.
    Kurano, M.
    Naka, S.
    Ota, S.
    Ideguchi, Y.
    Hasebe, N.
    Ogura, K.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1782 - 1785
  • [44] APPLICATIONS OF CR-39 NUCLEAR TRACK DETECTOR IN MEDICINE AND TECHNOLOGY
    HENSHAW, DL
    PHYSICS IN TECHNOLOGY, 1982, 13 (06): : 266 - &
  • [45] Calibration of CR-39 solid state nuclear track detector
    P. Wanabongse
    B. Sola
    J. Jamsangtong
    S. Rattanabussayaporn
    Indian Journal of Physics, 2009, 83 : 833 - 837
  • [46] Calibration of solid state nuclear track detector CR-39
    Ren, GX
    Jing, GR
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (06): : 596 - 598
  • [47] Calibration of CR-39 solid state nuclear track detector
    Wanabongse, P.
    Sola, B.
    Jamsangtong, J.
    Rattanabussayaporn, S.
    INDIAN JOURNAL OF PHYSICS, 2009, 83 (06) : 833 - 837
  • [48] STUDY ON THE SENSITIVITY OF SOLID-STATE NUCLEAR TRACK DETECTOR (SSNTD) CR-39 FOR ALPHA-PARTICLES REGISTRATION
    GABER, M
    ELKHIER, AAA
    FAHMI, NM
    ISOTOPENPRAXIS, 1991, 27 (07): : 346 - 349
  • [49] An approach to nuclear charge identification with CR-39 polymeric nuclear track detector
    Hafez, AF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 122 (01): : 133 - 140
  • [50] A Study of the Optical Characteristics of CR-39 Nuclear Track Detector Using Ultraviolet Irradiation
    Al-Nagaar, Tayseer, I
    Shabaan, Doaa H.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2021, 54 (04): : 85 - 88