Imaging Evaluation in Otosclerosis: Single Photon Emission Computed Tomography and Computed Tomography

被引:19
|
作者
Berrettini, Stefano [1 ]
Ravecca, Francesca [1 ]
Volterrani, Duccio [2 ]
Neri, Emanuele [3 ]
Forli, Francesca [1 ]
机构
[1] Univ Pisa, Dept Neurosci, Otol Cochlear Implant Sect, Pisa, Italy
[2] Univ Pisa, Reg Ctr Nucl Med, Pisa, Italy
[3] Univ Pisa, Dept Diagnost & Intervent Radiol, Pisa, Italy
来源
关键词
high-resolution computed tomography; otosclerosis; single photon emission computed tomography; SENSORINEURAL HEARING-LOSS; TYMPANO-COCHLEAR SCINTIGRAPHY; OF-THE-MONTH; TEMPORAL BONE; TYMPANOCOCHLEAR SCINTIGRAPHY; CT ANALYSIS; HISTOPATHOLOGY; IMPLANTATION; DENSITOMETRY; CAPSULE;
D O I
10.1177/000348941011900402
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: The aim of our study was to demonstrate the utility of diphosphonate bone single. photon emission computed tomography (SPECT) in diagnosing otosclerosis and to correlate the findings from SPECT with age. gender, and sensorineural hearing loss We also evaluated the ability of high-resolution computed tomography (HR-CT) in detecting otospongiotic and otosclerotic foci and correlated the HR-CT findings with the SPECT results Methods: Seventy-three subjects with surgically confirmed otosclerosis underwent SPECT. and 45 of the 73 patients also underwent HR-CT of the petrous bones Results: In the patient sample examined in this study. SPECT demonstrated a sensitivity of 95 2% and a specificity of about 96 7% By con elating the SPECT findings, we found an inverse relationship between bone radioactivity and age greater disease activity in younger patients and a direct relationship between bone radioactivity and the seventy of sensorineural impairment in younger patients In the 45 patients who also underwent HR-CT. the sensitivity of HR-CT (58%) was lower than that of SPECT, and the comparison between SPECT activity and the HR-CT findings (fenestral or retrofenestral type) demonstrated a statistically significant correlation between the morphological finding of bone demineralization (pericochlear foci) and a high uptake index Conclusions: The use of SPECT seems to be highly effective in differentiating normal from pathological petrous bone It also provides a quantitative evaluation of disease activity and shows a significant correlation with bone demineralization revealed by HR-CT
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
  • [41] Influence of Metal Implants on Quantitative Evaluation of Bone Single-Photon Emission Computed Tomography/Computed Tomography
    Oe, Keisuke
    Zeng, Feibi
    Niikura, Takahiro
    Fukui, Tomoaki
    Sawauchi, Kenichi
    Matsumoto, Tomoyuki
    Nogami, Munenobu
    Murakami, Takamichi
    Kuroda, Ryosuke
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (22)
  • [42] Advances in Cardiac Single Photon Emission Computed Tomography (SPECT) Imaging
    Henzlova, Milena J.
    SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2009, 13 (04) : 259 - 262
  • [43] Spatial resolution of pinhole single photon emission computed tomography imaging
    Dai Qiu-Sheng
    Qi Yu-Jin
    ACTA PHYSICA SINICA, 2010, 59 (02) : 1357 - 1365
  • [44] THALLIUM IMAGING WITH SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    ISKANDRIAN, AS
    HEO, J
    ASKENASE, A
    SEGAL, BL
    HELFANT, RH
    AMERICAN HEART JOURNAL, 1987, 114 (04) : 852 - 865
  • [45] Radiopharmaceuticals for single-photon emission computed tomography brain imaging
    Kung, HF
    Kung, MP
    Choi, SR
    SEMINARS IN NUCLEAR MEDICINE, 2003, 33 (01) : 2 - 13
  • [46] Aortic root abscess: Multimodality imaging with computed tomography and gallium-67 citrate single-photon emission computed tomography/computed tomography hybrid imaging
    McWilliams, Eric T.
    Yavari, Arash
    Raman, Vivek
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (02) : 122 - 124
  • [47] Hybrid cardiac single photon emission computed tomography/computed tomography imaging with myocardial perfusion single photon emission computed tomography and multidetector computed tomography coronary angiography for the assessment of unstable angina pectoris after coronary artery bypass grafting
    Ghersin, Eduard
    Keidar, Zohar
    Rispler, Shmuel
    Litmanovich, Diana
    Bar-Shalom, Rachel
    Roguin, Ariel
    Soil, Adrian
    Israel, Ora
    Engel, Ahuva
    CIRCULATION, 2006, 114 (06) : E237 - E239
  • [48] Magnetic resonance imaging, positron emission tomography, and single-photon-emission computed tomography in epilepsy
    Chong, BW
    Shelton, DK
    WESTERN JOURNAL OF MEDICINE, 1996, 165 (1-2): : 53 - 54
  • [49] Comparison of single photon emission computed tomography-computed tomography, computed tomography, single photon emission computed tomography and planar scintigraphy for characterization of isolated skull lesions seen on bone scintigraphy in cancer patients
    Sharma, Punit
    Jain, Tarun Kumar
    Reddy, Rama Mohan
    Faizi, Nauroze Ashgar
    Bal, Chandrasekhar
    Malhotra, Arun
    Kumar, Rakesh
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2014, 29 (01): : 22 - 29
  • [50] Comparison of multislice computed tomography to gated single-photon emission computed tomography for imaging of healed myocardial infarcts
    Henneman, Maureen M.
    Schuijf, Joanne D.
    Dibbets-Schneider, Petra
    Stokkel, Marcel P.
    van der Geest, Rob J.
    van der Wall, Ernst E.
    Bax, Jeroen J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (02): : 144 - 148