A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy

被引:85
|
作者
Arnfield, MR [1 ]
Siebers, JV
Kim, JO
Wu, QW
Keall, PJ
Mohan, R
机构
[1] Virginia Commonwealth Univ, Med Coll Virginia, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] McGuire VA Hosp, Richmond, VA 23298 USA
关键词
multileaf collimator; intensity modulated radiotherapy; dosimetry; Monte Carlo method;
D O I
10.1118/1.1312190
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The main purpose of this work is to demonstrate a practical means of determining the leaf transmission and scatter characteristics of a multileaf collimator (MLC) pertinent to the commissioning of dynamic intensity modulated radiotherapy, especially for the sweeping window technique. The data are necessary for the conversion of intensity distributions produced by intensity-modulated radiotherapy optimization systems into trajectories of MLC leaves for dynamic delivery. Measurements are described for two, tungsten alloy MLCs: a Mark II 80-leaf MLC on a Varian 2100C accelerator and a Millenium 120-leaf MLC on a Varian 2100EX accelerator. MLC leakage was measured by film for a series of held sizes. Measured MLC leakage was 1.68% for a 10x10 cm(2) field for both 6 and 18 MV for the 80-leaf MLC. For the 6 MV field, the 1.68% leakage consisted of 1.48% direct transmission and 0.20% leaf scatter. Direct transmission through the 80-leaf MLC, including the rounded leaf tip, was calculated analytically taking into account the detailed leaf geometry and a Monte Carlo-generated energy spectrum of the accelerator. The integrated fluence under the leaf tip was equivalent to an inward shift of 0.06 cm of a hypothetical leaf with a flat, focused tip. Monte Carlo calculations of the dose to phantom beyond a closed 80-leaf MLC showed excellent agreement with the analytic results. The transmission depends on the density of the MLC alloy, which may differ among individual MLCs. Thus, it is important to measure the transmission of any particular MLC. Calculated doses for a series of uniform fields produced by dynamic sweeping windows of various widths agree with measurements within 2%. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01810-1].
引用
收藏
页码:2231 / 2241
页数:11
相关论文
共 50 条
  • [1] An Improved Sequencing Algorithm for Dynamic Multileaf Collimator in Intensity Modulated Radiotherapy
    Jia, J.
    Chow, J.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [2] A simple plan validation procedure for intensity-modulated radiotherapy with dynamic multileaf collimator
    Selvaraj, R
    King, G
    Chern, SS
    Lalonde, R
    Wu, A
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1268 - 1269
  • [3] FOUR-DIMENSIONAL INTENSITY-MODULATED RADIOTHERAPY PLANNING FOR DYNAMIC MULTILEAF COLLIMATOR TRACKING RADIOTHERAPY
    Liang, Yueqiang
    Xu, Hongbing
    Yao, Jonathan
    Li, Zhihui
    Chen, Wendy
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (01): : 266 - 274
  • [4] Delivery of intensity-modulated treatments with dynamic multileaf collimator
    Boyer, AL
    Strait, JP
    [J]. PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 13 - 15
  • [5] Segmental and dynamic intensity-modulated radiotherapy delivery techniques for micro-multileaf collimator
    Agazaryan, N
    Solberg, TD
    [J]. MEDICAL PHYSICS, 2003, 30 (07) : 1758 - 1767
  • [6] Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode
    LoSasso, T
    Chui, CS
    Ling, CC
    [J]. MEDICAL PHYSICS, 2001, 28 (11) : 2209 - 2219
  • [7] Commissioning and quality assurance in intensity modulated radiotherapy (IMRT) treatment with dynamic multileaf collimator (dMLC)
    Venencia, C
    Besa, P
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1498 - 1498
  • [8] Comparison of two different plan validation techniques for intensity modulated radiotherapy with dynamic multileaf collimator
    Selvaraj, RN
    Wu, A
    King, GC
    Moreland, R
    Lalonde, R
    Gerszten, K
    Varlotto, J
    Kalnicki, S
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1500 - 1500
  • [9] Fluence segmentation for micro intensity modulated radiotherapy with a miniature multileaf collimator
    Bues, M
    Kooy, HM
    Hoban, P
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 303 - 304
  • [10] Dose deviations caused by positional inaccuracy of multileaf collimator in intensity modulated radiotherapy
    Wang, H. C.
    Chui, C. S.
    Tsai, H. Y.
    Chen, C. H.
    Tsai, L. F.
    [J]. RADIATION MEASUREMENTS, 2008, 43 (2-6) : 925 - 928