Hair sparing IMRT for whole brain with simultaneous integrated boosts

被引:0
|
作者
Mallah, J. [1 ]
Mihailidis, D. [1 ]
Plants, B. [1 ]
Fischer, T. [1 ]
机构
[1] Charleston Radiat Therapy Consultants, Charleston, WV USA
关键词
D O I
10.1118/1.2760901
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate inclusion of the hair‐sparing limitation of scalp dose as a secondary objective in a protocol for whole brain IMRT treatment along with high dose simultaneous integrated boosts (SIB) added to help control gross brain metastases. Methods and Materials: Three patients were selected to simulate a variety of brain tumors using artificial GTVs. The target doses were 54 Gy or 45 Gy for the boosts, and 27 Gy for the remainder of the whole brain, in 15 fx. To implement hair sparing, a 5 mm thick hair shell within the patient contour was created. Typical planning objectives for the hair shell were a max DVH constraint of 1250 cGy to 50% volume, and a max dose objective of 2300 cGy. Planning was done using Phillips Pinnacle3 (V7.4f) software configured for step‐and‐shoot treatment on a Siemens Primus unit with 6‐MV photons. Results: The high‐dose boost regions were found to require at least 5 beams but did not substantially degrade the whole brain DVH or hair DVH. However, for a PTV near the surface it was not possible to keep the hair dose low. The DVH may appear acceptable in such cases, but dose on the inner side of the 5 mm region will not cause hair loss, while a patch of high dose on the surface will. Conclusions: IMRT can provide a clinically viable avenue for hair‐sparing whole brain treatment with SIB to higher primary tumor doses. A specific region of interest that would represent the “hair sparing” region might need to be defined and be assigned a specific dose limiting objective during the optimization process. We found that hair‐sparing cannot successfully be satisfied for primary targets situated closer to the surface. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2456 / 2457
页数:2
相关论文
共 50 条
  • [41] Whole-brain radiotherapy with hippocampus sparing and simultaneous integrated boost to metastases: A plan quality comparison study between Ethos, HyperArc, VMAT and Tomotherapy
    Akdeniz, Yucel
    Ispir, Burcin
    MEDICAL DOSIMETRY, 2024, 49 (03) : 185 - 191
  • [42] Conformal Avoidance of Hippocampus during Whole Brain Radiation Therapy (WBRT) with Simultaneously Integrated Boosts (SIB)
    Naccarato, S.
    Sarnelli, A.
    Furini, G.
    Polico, R.
    Ruggieri, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S846 - S847
  • [43] Phase II Clinical Trial of Hippocampal-Sparing Whole Brain Irradiation and Simultaneous Integrated Boost Tomotherapy (SIB-TOMO) for Brain Metastases in Patients with Lung Cancer
    Wang, W. Q.
    Zhou, Z.
    Deng, L.
    Wang, J.
    Bi, N.
    Zhang, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E552 - E552
  • [44] Comparison of Treatment Schedules between Elekta Synergy and Varian Halcyon Linear Accelerators for Whole-brain Irradiation (WBRT) of multiple Brain Metastases with simultaneous Hippocampal Sparing (HA) and simultaneous integrated Boost (SIB)
    Kraft, J.
    Tamihardja, J.
    Weick, S.
    Breuer, K.
    Lutyj, P.
    Lisowski, D.
    Lewitzki, V.
    Polat, B.
    Flentje, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2022, 198 (SUPPL 1) : S80 - S80
  • [45] Hippocampus sparing in whole-brain radiotherapy
    Oskan, F.
    Ganswindt, U.
    Schwarz, S. B.
    Manapov, F.
    Belka, C.
    Niyazi, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 (04) : 337 - 341
  • [46] Role of Simultaneous Integrated Boost IMRT in Carcinoma Breast
    Behera, M. K.
    Sharma, A.
    Shukla, P.
    Ansari, F.
    Sharma, S.
    Manigandam, D.
    Sharma, D. N.
    Deo, S. V. S.
    Julka, P. K.
    Rath, G. K.
    EUROPEAN JOURNAL OF CANCER, 2012, 48 : S182 - S182
  • [47] Bi-tangential hybrid IMRT for sparing the shoulder in whole breast irradiation
    Farace, P.
    Deidda, M. A.
    de Curtis, I. Iamundo
    Deiana, E.
    Farigu, R.
    Lay, G.
    Porru, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (11) : 967 - 971
  • [48] The simultaneous integrated boost with protons or with IMRT in head and neck
    Cozzi, L
    Bolsi, A
    Fogliata, A
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 104 - 104
  • [49] Steep dose gradients for simultaneous integrated boost IMRT
    Bratengeier, Klaus
    Meyer, Juergen
    Schwab, Franz
    Vordermark, Dirk
    Flentje, Michael
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2009, 19 (02): : 129 - 135
  • [50] Comparison between simultaneous integrated boost IMRT and sequential IMRT in head and neck cancers
    Ahlawat, P.
    Gairola, M.
    Sharief, M. I.
    Tandon, S.
    Purohit, S.
    Sachdeva, N.
    Singh, T.
    Dobriyal, K.
    Krishnan, A.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S791 - S791