Hair sparing IMRT for whole brain with simultaneous integrated boosts

被引:0
|
作者
Mallah, J. [1 ]
Mihailidis, D. [1 ]
Plants, B. [1 ]
Fischer, T. [1 ]
机构
[1] Charleston Radiat Therapy Consultants, Charleston, WV USA
关键词
D O I
10.1118/1.2760901
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate inclusion of the hair‐sparing limitation of scalp dose as a secondary objective in a protocol for whole brain IMRT treatment along with high dose simultaneous integrated boosts (SIB) added to help control gross brain metastases. Methods and Materials: Three patients were selected to simulate a variety of brain tumors using artificial GTVs. The target doses were 54 Gy or 45 Gy for the boosts, and 27 Gy for the remainder of the whole brain, in 15 fx. To implement hair sparing, a 5 mm thick hair shell within the patient contour was created. Typical planning objectives for the hair shell were a max DVH constraint of 1250 cGy to 50% volume, and a max dose objective of 2300 cGy. Planning was done using Phillips Pinnacle3 (V7.4f) software configured for step‐and‐shoot treatment on a Siemens Primus unit with 6‐MV photons. Results: The high‐dose boost regions were found to require at least 5 beams but did not substantially degrade the whole brain DVH or hair DVH. However, for a PTV near the surface it was not possible to keep the hair dose low. The DVH may appear acceptable in such cases, but dose on the inner side of the 5 mm region will not cause hair loss, while a patch of high dose on the surface will. Conclusions: IMRT can provide a clinically viable avenue for hair‐sparing whole brain treatment with SIB to higher primary tumor doses. A specific region of interest that would represent the “hair sparing” region might need to be defined and be assigned a specific dose limiting objective during the optimization process. We found that hair‐sparing cannot successfully be satisfied for primary targets situated closer to the surface. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2456 / 2457
页数:2
相关论文
共 50 条
  • [1] Hippocampus-sparing whole-brain IMRT and simultaneous integrated boost to multiple brain metastases
    Cilla, S.
    Deodato, F.
    Ferro, M.
    Macchia, G.
    Ianiro, A.
    Picardi, V.
    Boccardi, M.
    Ferro, M.
    Cammelli, S.
    Arcelli, A.
    Farina, E.
    Giaccherini, L.
    Frezza, G. P.
    Valentini, V.
    Morganti, A. G.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S850 - S850
  • [2] Hair-sparing whole brain radiotherapy with simultaneous integrated boost using high density bolus
    Velazquez Miranda, S.
    Montero-Perea, E.
    Dorado-Dorado, R.
    Rubio, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S541 - S542
  • [3] DOSIMETRY ANALYSIS ON IMRT-VMAT TECHNIQUE IN HIPPOCAMPAL SPARING WHOLE BRAIN IRRADIATION WITH SIMULTANEOUS INTEGRATED BOOST FOR METASTATIC CANCER
    Anica, A.
    Suditu, M. D.
    Olarescu, A. D.
    Militaru, E. L.
    Miu, C. M.
    Oprea, A. M.
    Stanculeanu, D. L.
    ROMANIAN REPORTS IN PHYSICS, 2022, 74 (03)
  • [4] Overdose areas in whole brain irradiation with simultaneous integrated boost and hippocampal sparing
    Pierelli, A.
    Giri, M. G.
    Polloniato, P. M.
    Cernusco, N. L. V.
    Micera, R.
    Muraglia, A.
    Mazzarotto, R.
    Cavedon, C.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S817 - S817
  • [5] A Dosimetric Study of the Feasibility of Hippocampal and Hair Sparing Whole Brain Irradiation with Intensity Modulated Radiation Therapy (IMRT)
    Witek, M. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S798 - S799
  • [6] Dosimetric and radiobiological comparison of IMRT, VMAT, and helical tomotherapy planning techniques in hippocampal sparing whole brain radiotherapy with simultaneous integrated boost for multiple brain metastases
    Balasubramanian, S.
    Shobana, M. K.
    Anabalagan, D.
    Thanasekar, P.
    Joel, S.
    Chaudhary, Prekshi
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (01) : 47 - 57
  • [7] Dosimetric and radiobiological comparison of IMRT, VMAT, and helical tomotherapy planning techniques in hippocampal sparing whole brain radiotherapy with simultaneous integrated boost for multiple brain metastases
    S. Balasubramanian
    M. K. Shobana
    D. Anabalagan
    P. Thanasekar
    S. Joel
    Prekshi Chaudhary
    Radiation and Environmental Biophysics, 2024, 63 : 47 - 57
  • [8] Treatment of node-positive anal cancer by IMRT with simultaneous integrated boosts
    Burri, P.
    Manser, P.
    Kemmerling, L.
    Vetterli, D.
    Bigler, R.
    Mini, R.
    Greiner, R.
    Aebersold, D. M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 168 - 168
  • [9] Whole Field Simultaneous Integrated Boost IMRT in Nasopharyngeal Cancer
    Igdem, S.
    Altun, M.
    Alco, G.
    Ercan, T.
    Tecimer, C.
    Koeksal, G.
    Guerses, K.
    Demir, G.
    Okkan, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S478 - S478
  • [10] Hair-Sparing Whole Brain IMRT and Topical Tempol in Patients with Brain Metastases: A Prospective Phase II Trial for the Prevention of Iatrogenic Alopecia
    Gallant, F. A.
    Azoulay, M.
    Roberge, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S677 - S677