Deformable image registration by adaptive Gaussian forces

被引:0
|
作者
Pekar, V
Gladilin, E
机构
[1] Philips Res, D-22335 Hamburg, Germany
[2] Zuse Inst Berlin, D-14195 Berlin, Germany
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper introduces a novel physics-based approach to elastic image registration. It is based on applying Gaussian-shaped forces at irregularly distributed control points in the image, which is considered to be an infinite elastic continuum. The positions of the control points, the directions and magnitudes of the applied forces as well as their influence areas, and the elastic material properties are optimized to reach a maximum of the similarity measure between the images. The use of the adaptive irregular grid potentially allows to achieve good registration quality by using fewer parameters as compared to regular grids, e.g. B-splines. The feasibility of the proposed approach is tested on clinical images, and open problems and directions for future work are discussed.
引用
收藏
页码:317 / 328
页数:12
相关论文
共 50 条
  • [21] DIRART - a Software Suite for Deformable Image Registration and Adaptive Radiotherapy Research
    Yang, D.
    El Naqa, I.
    Apte, A.
    Wu, Y.
    Goddu, S.
    Mutic, S.
    Deasy, J.
    Low, D.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [22] Design of Large Deformable Lung Image Registration Network with Adaptive Window
    Yi, Jianbing
    Chen, Xi
    Cao, Feng
    Yang, Shuxin
    Chen, Xin
    [J]. Guangxue Xuebao/Acta Optica Sinica, 44 (19):
  • [23] Robust quality assurance criteria for deformable image registration for adaptive radiotherapy
    Bosma, L.
    Zachiu, C.
    de Senneville, B. Denis
    Raaymakers, B.
    Ries, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S323 - S324
  • [24] LOCALLY-ADAPTIVE SIMILARITY METRIC FOR DEFORMABLE MEDICAL IMAGE REGISTRATION
    Tang, Lisa
    Hero, Alfred
    Hamarneh, Ghassan
    [J]. 2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 728 - 731
  • [25] ACCURACY OF DEFORMABLE IMAGE REGISTRATION FOR CONTOUR PROPAGATION IN ADAPTIVE LUNG RADIOTHERAPY
    Hardcastle, N.
    van Elmpt, W.
    Oechsner, M.
    Guckenberger, M.
    De Ruysscher, D.
    Bzdusek, K.
    Tome, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S479 - S479
  • [26] Commissioning and validation of commercial deformable image registration software for adaptive contouring
    Jamema, Swamidas V.
    Phurailatpam, Reena
    Paul, Siji N.
    Joshi, Kishore
    Deshpande, D. D.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 47 : 1 - 8
  • [27] Deformable Image Registration with a Scale-adaptive Convolutional Neural Network
    Sang, Yudi
    Ruan, Dan
    [J]. 2020 IEEE 20TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE 2020), 2020, : 556 - 562
  • [28] It is not appropriate to "deform" dose along with deformable image registration in adaptive radiotherapy
    Schultheiss, Timothy E.
    Tome, Wolfgang A.
    Orton, Colin G.
    [J]. MEDICAL PHYSICS, 2012, 39 (11) : 6531 - 6533
  • [29] CONDITIONAL DEFORMABLE IMAGE REGISTRATION WITH SPATIALLY-VARIANT AND ADAPTIVE REGULARIZATION
    Wang, Yinsong
    Qiu, Huaqi
    Qin, Chen
    [J]. 2023 IEEE 20TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, ISBI, 2023,
  • [30] Learning Deformable Image Registration with Structure Guidance Constraints for Adaptive Radiotherapy
    Kuckertz, Sven
    Papenberg, Nils
    Honegger, Jonas
    Morgas, Tomasz
    Haas, Benjamin
    Heldmann, Stefan
    [J]. BIOMEDICAL IMAGE REGISTRATION (WBIR 2020), 2020, 12120 : 44 - 53