Laboratory scaled third rail deicing comparative test

被引:1
|
作者
Brassard, Jean-Denis [1 ]
Villeneuve, Eric [1 ]
Volat, Christophe [1 ]
机构
[1] Univ Quebec Chicoutimi, Antiicing Mat Int Lab, Chicoutimi, PQ, Canada
关键词
Icing; Rails; Deicing chemical; Ice; Winter;
D O I
10.1016/j.rineng.2020.100132
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The train transportation networks in northern countries are, during winter, affected by the frozen and freezing precipitations. The most affected part is the conductive rail denoted as the third rail. Although the two other rails are easily deiced, the third rail is only in contact with a conductive shoe that does not give enough force to properly remove the ice. This paper proposes a new comparative test to evaluate the required force to remove the ice on a scaled down rail under controlled conditions in a cold room. Experimentations have been performed under simulated freezing drizzle at -10 degrees C on a steel rail bare and covered with protection coatings or fluids. The results obtained have proven the efficiency of the test method for the comparison, the classification and the selection of the best candidate products for outdoor test campaigns.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] Introducing the new third rail: immigration
    Colvin, G
    FORTUNE, 2004, 149 (01) : 44 - 44
  • [32] Third Rail Custody: The Military Case
    Sullivan, Mark E.
    JUVENILE AND FAMILY COURT JOURNAL, 2014, 65 (01) : 45 - 72
  • [33] Third Rail: An Eddy Harkness Novel
    Goldberg, Edward
    LIBRARY JOURNAL, 2014, 139 (08) : 62 - 62
  • [34] Creep force characteristics between rail and wheel on scaled model
    Matsumoto, A
    Sato, Y
    Ono, H
    Wang, YJ
    Yamamoto, M
    Tanimoto, M
    Oka, Y
    WEAR, 2002, 253 (1-2) : 199 - 203
  • [35] Deicing of The Contact Lines of the High-Speed Electric Railways: Deicing Configurations. Experimental Test Results
    Cinieri, Enrico
    Fumi, Alvaro
    IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (06) : 2580 - 2587
  • [36] STATISTICAL COMPARISON OF DIFFERENT SCALED LABORATORY DETERMINATIONS
    HAASE, W
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (08): : 588 - 588
  • [37] Comparative studies on laboratory rutting test and evaluating indicator of asphalt concrete
    Zhou, Dong
    Zhou, Zhigang
    Liu, Jingyu
    Journal of Railway Science and Engineering, 2022, 19 (08) : 2287 - 2294
  • [38] Comparative Study on Laboratory and Field Test of Maximum Dynamic Shear Modulus
    Sun, Jing
    Yuan, Xiao-ming
    Gong, Mao-sheng
    PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 478 - +
  • [39] A Scaled-Down Microgrid Laboratory Testbed
    Liu, Yusi
    Farnell, Chris
    George, Kenny
    Mantooth, H. Alan
    Balda, Juan Carlos
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 1184 - 1189
  • [40] Comparative measures of the toxicity of component chemicals in aircraft deicing fluid
    Cornell, JS
    Pillard, DA
    Hernandez, MT
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2000, 19 (06) : 1465 - 1472