Combining preconcentration of air samples with cavity ring-down spectroscopy for detection of trace volatile organic compounds in the atmosphere

被引:18
|
作者
Parkes, AM [1 ]
Lindley, RE [1 ]
Orr-Ewing, AJ [1 ]
机构
[1] Univ Bristol, Sch Chem, Bristol BS8 1TS, Avon, England
关键词
D O I
10.1021/ac048727j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitative detection of small volatile organic compounds in ambient air is demonstrated using a combination of continuous wave cavity ring-down spectroscopy (cw-CRDS) and the preconcentration. of air samples with an adsorbent trap. The trap consists of a zeolite molecular sieve, selected for efficient trapping of the test compounds ethene (ethylene) and ethyne (acetylene). Upon heating of the trap, these organic compounds desorb into a small-volume ring-down cavity, and absolute concentrations are measured by CRDS at 6150.30 cm(-1) (ethene) and 6512.99 cm(-1) (ethyne) without the need for calibration. The efficiency of the trapping and desorption was tested using commercial standard gas mixtures and shown to be 100% in the case of ethene, whereas some ethyne is retained under the current operating conditions. Samples of indoor and outdoor air were analyzed for ethene content, and measurements were made of mixing ratios as low as 6 ppbv. Removal of water vapor and CO2 from the air samples prior to trapping was unnecessary, and the selectivity of the trapping, desorption, and spectroscopic detection steps eliminates the need for gas chromatographic separation prior to analysis. With anticipated improvements to the design, measurements of these and other trace atmospheric constituents should be possible on time scales of a few minutes.
引用
收藏
页码:7329 / 7335
页数:7
相关论文
共 50 条
  • [21] Cavity Ring-Down Spectroscopy for trace species detection - art. no. 675607
    Chen, Yu
    Yan, Wen-Bin
    [J]. CHEMICAL AND BIOLOGICAL SENSORS FOR INDUSTRIAL AND ENVIRONMENTAL MONITORING III, 2007, 6756 : 75607 - 75607
  • [22] Optical heterodyne detection in cavity ring-down spectroscopy
    Levenson, MD
    Paldus, BA
    Spence, TG
    Harb, CC
    Harris, JS
    Zare, RN
    [J]. CHEMICAL PHYSICS LETTERS, 1998, 290 (4-6) : 335 - 340
  • [23] Trace Carbon Monoxide Detection with a Cavity Ring-Down Spectrometer
    Chen Bing
    Zhou Ze-yi
    Kang Peng
    Liu An-wen
    Hu Shui-ming
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35 (04) : 971 - 974
  • [24] Open-path cavity ring-down spectroscopy for trace gas measurements in ambient air
    McHale, Laura E.
    Hecobian, Arsineh
    Yalin, Azer P.
    [J]. OPTICS EXPRESS, 2016, 24 (05): : 5523 - 5535
  • [25] Trace gas analysis by diode laser cavity ring-down spectroscopy
    Yan, WB
    [J]. LEOS 2001: 14TH ANNUAL MEETING OF THE IEEE LASERS & ELECTRO-OPTICS SOCIETY, VOLS 1 AND 2, PROCEEDINGS, 2001, : 873 - 874
  • [26] Detection of S-Nitroso Compounds by Use of Midinfrared Cavity Ring-Down Spectroscopy
    Stsiapura, Vitali I.
    Shuali, Vincent K.
    Gaston, Benjamin M.
    Lehmann, Kevin K.
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (06) : 3345 - 3353
  • [27] Trace gas analysis by diode laser cavity ring-down spectroscopy
    Yan, WB
    [J]. TEST AND MEASUREMENT APPLICATIONS OF OPTOELECTRONIC DEVICES, 2002, 4648 : 156 - 164
  • [28] Trace gas analysis by diode laser cavity ring-down spectroscopy
    Yan, WB
    Krusen, C
    Optics, T
    Dudek, J
    Lehmann, K
    Rabinowitz, P
    [J]. 2002 IEEE/SEMI ADVANCED SEMICONDUCTOR MANUFACTURING CONFERENCE AND WORKSHOP: ADVANCING THE SCIENCE OF SEMICONDUCTOR MANUFACTURING EXCELLENCE, 2002, : 319 - 323
  • [29] Automated system for monitoring trace C2H2 in ambient air by cavity ring-down spectroscopy combined with sample preconcentration
    Pradhan, Manik
    Aziz, M. S. I.
    Grilli, Roberto
    Orr-Ewing, Andrew J.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2008, 42 (19) : 7354 - 7359
  • [30] Single-cell detection by cavity ring-down spectroscopy
    Tarsa, PB
    Wist, AD
    Rabinowitz, P
    Lehmann, KK
    [J]. APPLIED PHYSICS LETTERS, 2004, 85 (19) : 4523 - 4525