Combining preconcentration of air samples with cavity ring-down spectroscopy for detection of trace volatile organic compounds in the atmosphere

被引:18
|
作者
Parkes, AM [1 ]
Lindley, RE [1 ]
Orr-Ewing, AJ [1 ]
机构
[1] Univ Bristol, Sch Chem, Bristol BS8 1TS, Avon, England
关键词
D O I
10.1021/ac048727j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitative detection of small volatile organic compounds in ambient air is demonstrated using a combination of continuous wave cavity ring-down spectroscopy (cw-CRDS) and the preconcentration. of air samples with an adsorbent trap. The trap consists of a zeolite molecular sieve, selected for efficient trapping of the test compounds ethene (ethylene) and ethyne (acetylene). Upon heating of the trap, these organic compounds desorb into a small-volume ring-down cavity, and absolute concentrations are measured by CRDS at 6150.30 cm(-1) (ethene) and 6512.99 cm(-1) (ethyne) without the need for calibration. The efficiency of the trapping and desorption was tested using commercial standard gas mixtures and shown to be 100% in the case of ethene, whereas some ethyne is retained under the current operating conditions. Samples of indoor and outdoor air were analyzed for ethene content, and measurements were made of mixing ratios as low as 6 ppbv. Removal of water vapor and CO2 from the air samples prior to trapping was unnecessary, and the selectivity of the trapping, desorption, and spectroscopic detection steps eliminates the need for gas chromatographic separation prior to analysis. With anticipated improvements to the design, measurements of these and other trace atmospheric constituents should be possible on time scales of a few minutes.
引用
收藏
页码:7329 / 7335
页数:7
相关论文
共 50 条
  • [1] Trace detection of volatile organic compounds by diode laser cavity ring-down spectroscopy
    Parkes, AM
    Fawcett, BL
    Austin, RE
    Nakamichi, S
    Shallcross, DE
    Orr-Ewing, AJ
    [J]. ANALYST, 2003, 128 (07) : 960 - 965
  • [2] Cavity ring-down spectroscopy for trace ammonia detection
    Qu Zhe-Chao
    Li Bin-Cheng
    Han Yan-Ling
    [J]. JOURNAL OF INFRARED AND MILLIMETER WAVES, 2012, 31 (05) : 431 - 436
  • [3] Detection of toxic compounds by cavity ring-down spectroscopy
    Research and Technology Park, Mississippi Stt. Univ. Diagn. I., 205 Research Boulevard, Starkville, MS 39759-9734, United States
    [J]. Environ. Sci. Technol., 11 (1936-1939):
  • [4] Detection of trace water in phosphine with cavity ring-down spectroscopy
    Lehman, SY
    Bertness, KA
    Hodges, JT
    [J]. JOURNAL OF CRYSTAL GROWTH, 2003, 250 (1-2) : 262 - 268
  • [5] Trace water detection in phosphine by cavity ring-down spectroscopy
    Lehman, SY
    Bertness, KA
    Hodges, JT
    [J]. PROGRESS IN SEMICONDUCTORS II- ELECTRONIC AND OPTOELECTRONIC APPLICATIONS, 2003, 744 : 419 - 424
  • [6] Trace Methane Detection Based on Cavity Ring-Down Spectroscopy
    Song Shao-man
    Yan Chang-xiang
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (07) : 2023 - 2028
  • [7] Trace gas detection with DFB lasers and cavity ring-down spectroscopy
    Morville, J
    Chenevier, M
    Kachanov, AA
    Romanini, D
    [J]. OPTICAL SPECTROSCOPIC TECHNIQUES, REMOTE SENSING, AND INSTRUMENTATION FOR ATMOSPHERIC AND SPACE RESEARCH IV, 2001, 4485 : 236 - 243
  • [8] Evanescent wave cavity ring-down spectroscopy for trace water detection
    Pipino, ACR
    Hodges, JT
    [J]. ADVANCED ENVIRONMENTAL AND CHEMICAL SENSING TECHNOLOGY, 2001, 4205 : 1 - 11
  • [9] Cavity ring-down spectroscopy for trace gas analysis
    Czyzewski, A
    Ernst, K
    Karasinski, G
    Lange, H
    Rairoux, P
    Skubiszak, W
    Stacewicz, T
    [J]. ACTA PHYSICA POLONICA B, 2002, 33 (08): : 2255 - 2265
  • [10] Measurement of Trace NH3 Concentration in Atmosphere by Cavity Ring-Down Spectroscopy
    Kou Xiaowen
    Zhou Bin
    Liu Xunchen
    Chen Haixuan
    Zhang Meng
    Liu Pengfei
    [J]. ACTA OPTICA SINICA, 2018, 38 (11)