Coronary artery flow measurement with magnetic resonance imaging: A validation with ultrasound

被引:0
|
作者
Wedding, KL [1 ]
Grist, TM [1 ]
Folts, JD [1 ]
Maalej, N [1 ]
Vigen, KK [1 ]
Peters, DC [1 ]
Osman, H [1 ]
Mistretta, CA [1 ]
机构
[1] Univ Wisconsin, Sch Med, Madison, WI USA
关键词
D O I
10.1016/S0735-1097(97)85363-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:381A / 381A
页数:1
相关论文
共 50 条
  • [31] Magnetic resonance imaging versus Doppler guide wire in the assessment of coronary flow reserve in patients with coronary artery disease
    Bedaux, WLF
    Hofman, MBM
    de Cock, CC
    Stoel, MG
    Visser, CA
    van Rossum, AC
    CORONARY ARTERY DISEASE, 2002, 13 (07) : 365 - 372
  • [32] Comparison of cardiac magnetic resonance imaging (CMRI) and SPECT for the assessment of flow limiting coronary artery stenoses
    Rieber, Johannes
    Hacker, Marcus
    Huber, Armin
    Jung, Philip
    Erhard, Isabelle
    Koneig, Andreas
    Poliklinik, Medizinische
    Hoffmann, Udo
    Klauss, Volker
    Poliklinik, Medizinische
    CIRCULATION, 2006, 114 (18) : 538 - 538
  • [33] Ultrasound Vector Flow Imaging Compared with Phase Contrast Magnetic Resonance Imaging for Estimating Blood Flow Velocity and Volume Flow in the Common Carotid Artery
    Du, Yigang
    Ding, Haiyan
    He, Le
    Deng, Linsong
    Yu, Alfred C. H.
    Yiu, Billy Y. S.
    Zhu, Lei
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [34] MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING
    CLARKE, GD
    ECKELS, R
    CHANEY, C
    SMITH, D
    DITTRICH, J
    HUNDLEY, WG
    NESSAIVER, M
    LI, HF
    PARKEY, RW
    PESHOCK, RM
    CIRCULATION, 1995, 91 (10) : 2627 - 2634
  • [35] Flow and distension in the carotid artery from magnetic resonance imaging
    Yim, PJ
    Demarco, JK
    MEDICAL IMAGING 2004: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2004, 5 (23): : 524 - 528
  • [36] Myocardial Perfusion Imaging After Coronary Artery Bypass Surgery Using Cardiovascular Magnetic Resonance A Validation Study
    Arnold, J. Ranjit
    Francis, Jane M.
    Karamitsos, Theodoros D.
    Lim, Chris C.
    van Gaal, William J.
    Testa, Luca
    Bhamra-Ariza, Paul
    Selvanayagam, Joseph B.
    Sayeed, Rana
    Westaby, Stephen
    Banning, Adrian P.
    Neubauer, Stefan
    Jerosch-Herold, Michael
    CIRCULATION-CARDIOVASCULAR IMAGING, 2011, 4 (03) : 312 - 318
  • [37] Clinical validation of intravascular ultrasound imaging for the assessment of the severity of coronary artery lesions
    Nagai, T
    Nishioka, T
    Amanullah, AM
    Luo, H
    Berglund, H
    Kim, CJ
    Siegel, RJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 : TC209 - TC209
  • [38] Coronary stent as a tubular flow heater in magnetic resonance imaging
    Vrtnik S.
    Wencka M.
    Jelen A.
    Kim H.J.
    Dolinšek J.
    Journal of Analytical Science and Technology, 6 (1)
  • [39] Determination of coronary blood flow velocity with magnetic resonance imaging
    Nagel, E
    Bernstedt, A
    Hug, J
    Wellnhofer, E
    Schnackenburg, B
    Fleck, E
    CIRCULATION, 1997, 96 (08) : 1381 - 1381
  • [40] MEASUREMENT OF TIME-AVERAGED FLOW IN THE MIDDLE CEREBRAL-ARTERY BY MAGNETIC-RESONANCE-IMAGING
    TARNAWSKI, M
    PADAYACHEE, S
    GRAVES, MJ
    TAYLOR, MG
    AYTON, VT
    SMITH, MA
    BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (758): : 178 - 181