Fat quantification with IDEAL gradient echo imaging:: Correction of bias from T1 and noise

被引:402
|
作者
Liu, Chia-Ying
McKenzie, Charles A.
Yu, Huanzhou
Brittain, Jean H.
Reeder, Scott B.
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53706 USA
[4] Univ Wisconsin, Dept Med, Madison, WI 53706 USA
[5] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[6] Harvard Univ, Sch Med, Boston, MA USA
[7] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[8] GE Healthcare, Global Appl Sci Lab, Madison, WI USA
关键词
fat quantification; IDEAL; chemical shift imaging; hepatic steatosis; magnetic resonance imaging;
D O I
10.1002/mrm.21301
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantification of hepatic steatosis is a significant unmet need for the diagnosis and treatment of patients with nonalcoholic fatty liver disease (NAFLD). MRI is capable of separating water and fat signals in order to quantify fatty infiltration of the liver (hepatic steatosis). Unfortunately, fat signal has confounding T-1 effects and the nonzero mean noise in low signal-to-noise ratio (SNR) magnitude images can lead to incorrect estimation of the true lipid percentage. In this study, the effects of bias from T-1 effects and image noise were investigated. An oil/water phantom with volume fat-fractions ranging linearly from 0% to 100% was designed and validated using a spoiled gradient echo (SPGR) sequence in combination with a chemical-shift based fat-water separation method known as iterative decomposition of water and fat with echo asymmetry and least squares estimation (IDEAL). We demonstrated two approaches to reduce the effects of T-1: small flip angle (flip angle) and dual flip angle methods. Both methods were shown to effectively minimize deviation of the measured fat-fraction from its true value. We also demonstrated two methods to reduce noise bias: magnitude discrimination and phase-constrained reconstruction. Both methods were shown to reduce this noise bias effectively from 15% to less than 1%.
引用
收藏
页码:354 / 364
页数:11
相关论文
共 50 条
  • [1] Fat-water separated myocardial T1 mapping with IDEAL-T1 saturation recovery gradient echo imaging
    Joseph J Pagano
    Kelvin Chow
    Ray Yang
    Richard B Thompson
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [2] MT effects and T1 quantification in single-slice spoiled gradient echo imaging
    Ou, Xiawei
    Gochberg, Daniel Frank
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (04) : 835 - 845
  • [3] Magnetic resonance T1 gradient-echo imaging in hepatolithiasis
    F. Safar
    T. Kamura
    K. Okamuto
    K. Sasai
    F. Gejyo
    Abdominal Imaging, 2005, 30 : 297 - 302
  • [4] Magnetic resonance T1 gradient-echo imaging in hepatolithiasis
    Safar, F
    Kamura, T
    Okamuto, K
    Sasai, K
    Gejyo, F
    ABDOMINAL IMAGING, 2005, 30 (03): : 297 - 302
  • [5] Relaxation effects in the quantification of fat using gradient echo imaging
    Bydder, Mark
    Yokoo, Takeshi
    Hamilton, Gavin
    Middleton, Michael S.
    Chavez, Alyssa D.
    Schwimmer, Jeffrey B.
    Lavine, Joel E.
    Sirlin, Claude B.
    MAGNETIC RESONANCE IMAGING, 2008, 26 (03) : 347 - 359
  • [6] Water-fat separation with IDEAL gradient-echo imaging
    Reeder, Scott B.
    McKenzie, Charles A.
    Pineda, Angel R.
    Yu, Huanzhou
    Shimakawa, Ann
    Brau, Anja C.
    Hargreaves, Brian A.
    Gold, Garry E.
    Brittain, Jean H.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 644 - 652
  • [7] Characterization of T1 bias in skeletal muscle from fat in MOLLI and SASHA pulse sequences: Quantitative fat-fraction imaging with T1 mapping
    Larmour, Sarah
    Chow, Kelvin
    Kellman, Peter
    Thompson, Richard B.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) : 237 - 249
  • [8] Evaluation of liver T1 using MOLLI gradient echo readout under the influence of fat
    Liu, Chia-Ying
    Noda, Chikara
    Ambale-Venkatesh, Bharath
    Kassai, Yoshimori
    Bluemke, David
    Lima, A. C.
    MAGNETIC RESONANCE IMAGING, 2022, 85 : 57 - 63
  • [9] Fat Fraction Bias Correction Using T1 Estimates and Flip Angle Mapping
    Yang, Issac Y.
    Cui, Yifan
    Wiens, Curtis N.
    Wade, Trevor P.
    Friesen-Waldner, Lanette J.
    McKenzie, Charles A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (01) : 217 - 223
  • [10] T1 and T2 quantification from standard turbo spin echo images
    McPhee, Kelly C.
    Wilman, Alan H.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 2052 - 2063