Calculating percent depth dose with the electron pencil-beam redefinition algorithm

被引:2
|
作者
Price, Michael J.
Hogstrom, Kenneth R.
Antolak, John A.
White, R. Allen
Bloch, Charles D.
Boyd, Robert A.
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77070 USA
[2] Univ Texas, Grad Sch Biomed Sci, Houston, TX USA
[3] Univ Texas, MD Anderson Canc Ctr, Dept Biomath, Houston, TX 77030 USA
来源
关键词
electron dose algorithm; pencil beam; depth dose;
D O I
10.1120/jacmp.v8i2.2443
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the present work, we investigated the accuracy of the electron pencil-beam redefinition algorithm (PBRA) in calculating central-axis percent depth dose in water for rectangular fields. The PBRA energy correction factor C(E) was determined so that PBRA-calculated percent depth dose best matched the percent depth dose measured in water. The hypothesis tested was that a method can be implemented into the PBRA that will enable the algorithm to calculate central-axis percent depth dose in water at a 100-cm source-to-surface distance (SSD) with an accuracy of 2% or 1-mm distance to agreement for rectangular field sizes >= 2 x 2 cm. Preliminary investigations showed that C(E), determined using a single percent depth dose for a large field (that is, having side-scatter equilibrium), was insufficient for the PBRA to accurately calculate percent depth dose for all square fields >= 2 x 2 cm. Therefore, two alternative methods for determining C(E) were investigated. In Method 1, C(E), modeled as a polynomial in energy, was determined by fitting the PBRA calculations to individual rectangular-field percent depth doses. In Method 2, C(E) for square fields, described by a polynomial in both energy and side of square W [ that is, C = C(E, W)], was determined by fitting the PBRA calculations to measured percent depth dose for a small number of square fields. Using the function C(E, W), C(E) for other square fields was determined, and C(E) for rectangular field sizes was determined using the geometric mean of C(E) for the two measured square fields of the dimension of the rectangle (square root method). Using both methods, PBRA calculations were evaluated by comparison with measured square-field and derived rectangular-field percent depth doses at 100-cm SSD for the Siemens Primus radiotherapy accelerator equipped with a 25 x 25-cm applicator at 10 MeV and 15 MeV. To improve the fit of C(E) and C(E, W) to the electron component of percent depth dose, it was necessary to modify the PBRA's photon depth dose model to include dose buildup. Results showed that, using both methods, the PBRA was able to predict percent depth dose within criteria for all square and rectangular fields. Results showed that second- or third-order polynomials in energy (Methods 1 and 2) and in field size (Method 2) were typically required. Although the time for dose calculation using Method 1 is approximately twice that using Method 2, we recommend that Method 1 be used for clinical implementation of the PBRA because it is more accurate (most measured depth doses predicted within approximately 1%) and simpler to implement.
引用
收藏
页码:61 / 75
页数:15
相关论文
共 50 条
  • [31] A pencil-beam photon algorithm for a miniature multileaf collimator
    Dong, L
    Shiu, AS
    Tung, SS
    Hogstrom, KR
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 92 - 95
  • [32] Electron dose calculation using multiple-scattering theory: A hybrid electron pencil-beam model
    Luo, ZM
    Jette, D
    Walker, S
    MEDICAL PHYSICS, 1998, 25 (10) : 1954 - 1963
  • [33] ELECTRON-BEAM ARC THERAPY PERCENT DEPTH DOSE
    GERBER, RL
    PURDY, JA
    MEDICAL PHYSICS, 1984, 11 (03) : 389 - 389
  • [34] Improving the Uniqueness of Numerically Extracted Proton Pencil-Beam Energy Spectrum from Integral Depth Dose
    Yao, W.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [35] Incorporation of the aperture thickness in proton pencil-beam dose calculations
    Slopsema, Roelf L.
    Kooy, Hanne M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (21): : 5441 - 5453
  • [36] EFFECT OF DIMENSIONALITY OF HETEROGENEITY CORRECTIONS ON THE IMPLEMENTATION OF A 3-DIMENSIONAL ELECTRON PENCIL-BEAM ALGORITHM
    STARKSCHALL, G
    SHIU, AS
    BUJNOWSKI, SW
    WANG, LL
    LOW, DA
    HOGSTROM, KR
    PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (02): : 207 - 227
  • [37] DOSIMETRIC EVALUATION OF A 2-DIMENSIONAL, ARC ELECTRON, PENCIL-BEAM ALGORITHM IN WATER AND PMMA
    KURUP, RG
    HOGSTROM, KR
    OTTE, VA
    MOYERS, MF
    TUNG, S
    SHIU, AS
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01): : 127 - 144
  • [38] Evaluation of a pencil-beam dose calculation technique for charged particle radiotherapy
    Petti, PL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (05): : 1049 - 1057
  • [39] Incorporating partial shining effects in proton pencil-beam dose calculation
    Li, Yupeng
    Zhang, Xiaodong
    Lii, MingFwu
    Sahoo, Narayan
    Zhu, Ron X.
    Gillin, Michael
    Mohan, Radhe
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (03): : 605 - 616
  • [40] Evaluation of IMRT Dose Calculation Based On Pencil-Beam and AAA Algorithms
    Yuan, Y.
    Duan, J.
    Popple, R.
    Brezovich, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3829 - 3829