Minimally invasive cardiac output technologies in the ICU: putting it all together

被引:17
|
作者
Clement, Ramon P. [1 ]
Vos, Jaap J. [2 ]
Scheeren, Thomas W. L. [2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Crit Care, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Anaesthesiol, Hanzepl 1,POB 30 001, NL-9700 RB Groningen, Netherlands
关键词
cardiac output; circulatory shock; functional haemodynamic monitoring; minimally invasive cardiac output monitoring; CRITICALLY-ILL PATIENTS; PULMONARY-ARTERY CATHETER; WAVE TRANSIT-TIME; STROKE VOLUME VARIATION; POLAR PLOT METHODOLOGY; 4TH GENERATION FLOTRAC; PULSE CONTOUR ANALYSIS; TRANSPULMONARY THERMODILUTION; APPLANATION TONOMETRY; MONITORING DEVICES;
D O I
10.1097/MCC.0000000000000417
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of reviewHaemodynamic monitoring is a cornerstone in the diagnosis and evaluation of treatment in critically ill patients in circulatory distress. The interest in using minimally invasive cardiac output monitors is growing. The purpose of this review is to discuss the currently available devices to provide an overview of their validation studies in order to answer the question whether these devices are ready for implementation in clinical practice.Recent findingsCurrent evidence shows that minimally invasive cardiac output monitoring devices are not yet interchangeable with (trans)pulmonary thermodilution in measuring cardiac output. However, validation studies are generally single centre, are based on small sample sizes in heterogeneous groups, and differ in the statistical methods used.SummaryMinimally and noninvasive monitoring devices may not be sufficiently accurate to replace (trans)pulmonary thermodilution in estimating cardiac output. The current paradigm shift to explore trending ability rather than investigating agreement of absolute values alone is to be applauded. Future research should focus on the effectiveness of these devices in the context of (functional) haemodynamic monitoring before adoption into clinical practice can be recommended.
引用
收藏
页码:302 / 309
页数:8
相关论文
共 50 条
  • [41] Comparison of an advanced minimally invasive cardiac output monitoring with a continuous invasive cardiac output monitoring during lung transplantation
    Tomasi, Roland
    Prueckner, Stephan
    Czerner, Stephan
    Schramm, Rene
    Preissler, Gerhard
    Zwissler, Bernhard
    von Dossow-Hanfstingl, Vera
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (04) : 475 - 480
  • [42] Comparison of an advanced minimally invasive cardiac output monitoring with a continuous invasive cardiac output monitoring during lung transplantation
    Roland Tomasi
    Stephan Prueckner
    Stephan Czerner
    Renè Schramm
    Gerhard Preissler
    Bernhard Zwißler
    Vera von Dossow-Hanfstingl
    Journal of Clinical Monitoring and Computing, 2016, 30 : 475 - 480
  • [43] MINIMALLY INVASIVE METHOD FOR DETERMINING CARDIAC-OUTPUT OF MARMOT
    ZATZMAN, ML
    RAY, WJ
    JOURNAL OF THERMAL BIOLOGY, 1978, 3 (02) : 104 - 104
  • [44] Safety and Minimally Invasive Cardiac Surgery Go Together. With Experience
    Padalino, Massimo A.
    ANNALS OF THORACIC SURGERY, 2022, 113 (03): : 903 - 903
  • [45] Minimally invasive cardiac output monitoring for a parturient with pulmonary hypertension
    Baron, C. M.
    Swedlo, D.
    Funk, D. J.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2013, 22 (01) : 78 - 80
  • [46] Naphazoline intoxication managed with minimally invasive cardiac output monitoring
    Oishi, Takatoshi
    Kashiura, Masahiro
    Yasuda, Hideto
    Kishihara, Yuki
    Tominaga, Keiichiro
    Tamura, Hiroyuki
    Moriya, Takashi
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2024, 77 : 233e5 - 233e7
  • [47] Performance of three minimally invasive cardiac output monitoring systems
    de Wilde, R. B. P.
    Geerts, B. F.
    Cui, J.
    van den Berg, P. C. M.
    Jansen, J. R. C.
    ANAESTHESIA, 2009, 64 (07) : 762 - 769
  • [48] Noninvasive and Minimally Invasive Cardiac Output Monitoring A Nursing Perspective
    Berndsen, Michelle
    DIMENSIONS OF CRITICAL CARE NURSING, 2022, 41 (03) : 121 - 123
  • [49] Minimally invasive cardiac output monitoring in intensive care unit
    Minnucci, C
    De Rosa, MC
    Granata, A
    Piazza, O
    De Robertis, E
    PANMINERVA MEDICA, 2005, 47 (04) : 269 - 269
  • [50] Minimally Invasive Extracorporeal Technologies Perspective in Pediatric Cardiac Surgery
    Condello, Ignazio
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2022, 37 (01) : 143 - 143