Minimally invasive cardiac output technologies in the ICU: putting it all together

被引:17
|
作者
Clement, Ramon P. [1 ]
Vos, Jaap J. [2 ]
Scheeren, Thomas W. L. [2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Crit Care, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Anaesthesiol, Hanzepl 1,POB 30 001, NL-9700 RB Groningen, Netherlands
关键词
cardiac output; circulatory shock; functional haemodynamic monitoring; minimally invasive cardiac output monitoring; CRITICALLY-ILL PATIENTS; PULMONARY-ARTERY CATHETER; WAVE TRANSIT-TIME; STROKE VOLUME VARIATION; POLAR PLOT METHODOLOGY; 4TH GENERATION FLOTRAC; PULSE CONTOUR ANALYSIS; TRANSPULMONARY THERMODILUTION; APPLANATION TONOMETRY; MONITORING DEVICES;
D O I
10.1097/MCC.0000000000000417
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of reviewHaemodynamic monitoring is a cornerstone in the diagnosis and evaluation of treatment in critically ill patients in circulatory distress. The interest in using minimally invasive cardiac output monitors is growing. The purpose of this review is to discuss the currently available devices to provide an overview of their validation studies in order to answer the question whether these devices are ready for implementation in clinical practice.Recent findingsCurrent evidence shows that minimally invasive cardiac output monitoring devices are not yet interchangeable with (trans)pulmonary thermodilution in measuring cardiac output. However, validation studies are generally single centre, are based on small sample sizes in heterogeneous groups, and differ in the statistical methods used.SummaryMinimally and noninvasive monitoring devices may not be sufficiently accurate to replace (trans)pulmonary thermodilution in estimating cardiac output. The current paradigm shift to explore trending ability rather than investigating agreement of absolute values alone is to be applauded. Future research should focus on the effectiveness of these devices in the context of (functional) haemodynamic monitoring before adoption into clinical practice can be recommended.
引用
收藏
页码:302 / 309
页数:8
相关论文
共 50 条
  • [1] Minimally invasive cardiac output monitors
    Drummond, Kate E.
    Murphy, Edward
    BJA EDUCATION, 2012, 12 (01) : 5 - 10
  • [2] Minimally invasive cardiac output monitoring
    Morgan, Patrick
    Al-Subaie, Nawaf
    Rhodes, Andrew
    CURRENT OPINION IN CRITICAL CARE, 2008, 14 (03) : 322 - 326
  • [3] Cardiac Output Assessed by Invasive and Minimally Invasive Techniques
    Lee, Allison J.
    Cohn, Jennifer Hochman
    Ranasinghe, J. Sudharma
    ANESTHESIOLOGY RESEARCH AND PRACTICE, 2011, 2011
  • [4] Diagnosing invasive pulmonary aspergillosis in ICU patients: putting the puzzle together
    Blot, Stijn
    Rello, Jordi
    Koulenti, Despoina
    CURRENT OPINION IN CRITICAL CARE, 2019, 25 (05) : 430 - 437
  • [5] Applications of minimally invasive cardiac output monitors
    Porhomayon J.
    Zadeii G.
    Congello S.
    Nader N.D.
    International Journal of Emergency Medicine, 5 (1)
  • [6] Minimally invasive measurement of cardiac output - essential or not?
    Kubitz, J. C.
    Richter, H. P.
    Reuter, D. A.
    Goetz, A. E.
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 2009, 50 : 389 - 400
  • [7] PUTTING IT ALL TOGETHER
    TURNER, G
    JOURNAL OF EXTENSION, 1977, 15 (MAY-J): : 76 - 78
  • [8] Putting it all together
    Hart's E and P, 2000, 73 (6 SUPPL.):
  • [9] Putting It All Together?
    Frankston, Bob
    IEEE CONSUMER ELECTRONICS MAGAZINE, 2015, 4 (01) : 104 - 106
  • [10] Putting it all together
    Pelc, C.E.
    Nonwovens Industry, 2000, 31 (04): : 82 - 88