Minimal residual cone-beam reconstruction with attenuation correction in SPECT

被引:8
|
作者
La, V [1 ]
Grangeat, P [1 ]
机构
[1] CEA, LETI, CEA Technol Avancees, Dept Syst, Grenoble 9, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 04期
关键词
D O I
10.1088/0031-9155/43/4/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents an iterative method based on the minimal residual algorithm for tomographic attenuation compensated reconstruction from attenuated cone-beam projections given the attenuation distribution. Unlike conjugate-gradient based reconstruction techniques, the proposed minimal residual based algorithm solves directly a quasisymmetric linear system, which is a preconditioned system. Thus it avoids the use of normal equations, which improves the convergence rate. Two main contributions are introduced. First, a regularization method is derived for quasisymmetric problems, based on a Tikhonov-Phillips regularization applied to the factorization of the symmetric part of the system matrix. This regularization is made spatially adaptive to avoid smoothing the region of interest. Second, our existing reconstruction algorithm for attenuation correction in parallel-beam geometry is extended to cone-beam geometry. A circular orbit is considered. Two preconditioning operators are proposed: the first one is Grangeat's inversion formula and the second one is Feldkamp's inversion formula. Experimental results obtained on simulated data are presented and the shadow zone effect on attenuated data is illustrated.
引用
收藏
页码:715 / 727
页数:13
相关论文
共 50 条
  • [1] Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction for SPECT
    Tang, QL
    Zeng, GSL
    Gullberg, GT
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13): : 3153 - 3170
  • [2] Analytical reconstruction for helical cone-beam SPECT with non-uniform attenuation correction
    Huang, Qiu
    Zeng, Gengsheng L.
    Gullberg, Grant T.
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1856 - 1859
  • [3] Analytical algorithm for 3D cone-beam SPECT reconstruction with uniform attenuation correction
    Bronnikov, A.V.
    [J]. IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 3 : 1417 - 1423
  • [4] IMPROVED CONE-BEAM SPECT VIA AN ACCURATE CORRECTION FOR NONUNIFORM PHOTON ATTENUATION
    WELCH, A
    WEBB, S
    FLOWER, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (07): : 909 - 928
  • [5] Effect of de-noising and DDRV correction on cone-beam SPECT reconstruction with non-uniform attenuation
    Zhang, Hao
    Wen, Junhai
    Yin, Wen
    Li, Cuifen
    Zhang, Kangping
    Liang, Zhengrong
    [J]. MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [6] Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction
    Tang, QL
    Zeng, GL
    Gullberg, GT
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3546 - 3550
  • [7] A RECONSTRUCTION ALGORITHM FOR HELICAL CONE-BEAM SPECT
    WENG, Y
    ZENG, GL
    GULLBERG, GT
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 1092 - 1101
  • [8] Exact fan-beam and 4π-acquisition cone-beam SPECT algorithms with uniform attenuation correction
    Tang, QL
    Zeng, GSL
    Wu, JS
    Gullberg, GT
    [J]. MEDICAL PHYSICS, 2005, 32 (11) : 3440 - 3447
  • [9] A FAST ITERATIVE RECONSTRUCTION ALGORITHM FOR CONE-BEAM SPECT
    LI, J
    JASZCZAK, RJ
    GREER, KL
    COLEMAN, RE
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P80 - P80
  • [10] A CONE-BEAM SPECT RECONSTRUCTION ALGORITHM WITH A DISPLACED CENTER OF ROTATION
    LI, JY
    JASZCZAK, RJ
    WANG, HL
    GULLBERG, GT
    GREER, KL
    COLEMAN, RE
    [J]. MEDICAL PHYSICS, 1994, 21 (01) : 145 - 152