EMTP simulation of synchronous machine from standstill to synchronization

被引:0
|
作者
Karaagac, U. [1 ]
Mahseredjian, J. [1 ]
Dennetiere, S. [2 ]
机构
[1] Ecole Polytech, Campus Univ Montreal,2900 Edouard Montpetit, Montreal, PQ H3T 1J4, Canada
[2] EDF Res & Dev, Paris, France
关键词
EMTP; synchronous machine; startup; static frequency convertor; pumped storage power plant;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the modeling and simulation studies for the startup of a 250 MVA pumped storage unit in pumping mode and the startup of a 65 MVA hydraulic unit as a corrective action following an uncontrolled islanding of an area due to an extreme contingency. The new synchronous machine (SM) module of EMTP-RV enables the simulation of the machine from standstill and makes it possible to use it for studies including: analysis of the disturbances generated by the operation of the static frequency convertor (SFC) during electrical startup of a pumped storage unit and simulation of system restoration following a complete collapse of a major part of an interconnection. The proposed model is validated by using field measurements from a 250 MVA pumped storage unit for the period from standstill to line operation including the synchronization of the machine to the grid.
引用
收藏
页码:3322 / +
页数:2
相关论文
共 50 条
  • [21] Influence of saturation on estimated synchronous machine parameters in standstill frequency response tests
    Verbeeck, J.
    Pintelon, R.
    Lataire, P.
    2000, IEEE, Piscataway, NJ, United States (20):
  • [22] INVESTIGATION OF AUTO-SYNCHRONIZATION OF A SYNCHRONOUS MACHINE
    KANDIAH, P
    SASTRY, KPR
    BURRIDGE, RE
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (02): : 325 - 325
  • [23] Influence of saturation on estimated synchronous machine parameters in standstill frequency response tests
    Verbeeck, J
    Pintelon, R
    Lataire, P
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2000, 15 (03) : 277 - 283
  • [24] Modelling and simulation of a synchronous machine
    Bruck, FM
    Himmelstoss, FA
    COM.P.EL. 98: 6TH WORKSHOP ON COMPUTER IN POWER ELECTRONICS, RECORD, 1998, : 81 - 86
  • [25] Modelling and simulation of a synchronous machine
    Bruck, F.M.
    Himmelstoss, F.A.
    IEEE Workshop on Computers in Power Electronics, 1998, : 81 - 86
  • [26] A voltage-behind-reactance synchronous machine model for the EMTP-type solution
    Wang, Liwei
    Jatskevich, Juri
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 467 - 467
  • [27] A voltage-behind-reactance synchronous machine model for the EMTP-type solution
    Wang, Liwei
    Jatskevich, Juri
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (04) : 1539 - 1549
  • [28] A SYNCHRONOUS MACHINE MODEL FOR 3-PHASE HARMONIC-ANALYSIS AND EMTP INITIALIZATION
    XU, WW
    DOMMEL, HW
    MARTI, JR
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1991, 6 (04) : 1530 - 1538
  • [29] SYNCHRONOUS-MACHINE STANDSTILL FREQUENCY-RESPONSE TEST DATA-ANALYSIS
    SAUNDERS, RM
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1991, 6 (03) : 564 - 571
  • [30] Sensorless control of a synchronous reluctance machine in the whole speed- and loadrange including standstill
    Hofer, M.
    Izaak, M.
    Schroedl, M.