Neutron-Beam-Shaping Assembly for Boron Neutron-Capture Therapy

被引:16
|
作者
Zaidi, L. [1 ,2 ]
Kashaeva, E. A. [1 ,3 ]
Lezhnin, S. I. [1 ,4 ,5 ]
Malyshkin, G. N. [1 ,3 ]
Samarin, S. I. [1 ,3 ]
Sycheva, T. V. [1 ]
Taskaev, S. Yu. [1 ,5 ]
Frolov, S. A. [1 ,3 ]
机构
[1] Russian Acad Sci, Siberian Branch, Budker Inst Nucl Phys, Pr Akad Lavrentieva 11, Novosibirsk 630090, Russia
[2] Univ Sci & Technol Houari Boumediene, BP 32 El Alia 16111, Bab Ezzouar 16111, Algeria
[3] Zababakhin All Russian Sci Res Inst Tech Phys VNI, POB 245, Snezhinsk, Chelyabinsk Obl, Russia
[4] Russian Acad Sci, Novosibirsk Branch, Nucl Safety Inst, Pr Akad Lavrentieva 1, Novosibirsk 630090, Russia
[5] Novosibirsk State Univ, Ul Pirogova 2, Novosibirsk 630090, Russia
基金
俄罗斯科学基金会;
关键词
OPTIMIZATION; BNCT; PARAMETERS; DESIGN;
D O I
10.1134/S106377881701015X
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
A neutron-beam-shaping assembly consisting of a moderator, a reflector, and an absorber is used to form a therapeutic neutron beam for the boron neutron-capture therapy of malignant tumors at accelerator neutron sources. A new structure of the moderator and reflector is proposed in the present article, and the results of a numerical simulation of the neutron spectrum and of the absorbed dose in a modified Snyder head phantom are presented. The application of a compositemoderator and of a composite reflector and the implementation of neutron production at the proton energy of 2.3MeVare shown to permit obtaining a high-quality therapeutic neutron beam.
引用
收藏
页码:60 / 66
页数:7
相关论文
共 50 条
  • [21] BORON NEUTRON-CAPTURE THERAPY IN THE TREATMENT OF GLIOBLASTOMA
    ASHTARI, M
    BROWNELL, GL
    MEDICAL PHYSICS, 1981, 8 (05) : 736 - 736
  • [22] DOSE BRACKETING IN BORON NEUTRON-CAPTURE THERAPY
    GAHBAUER, R
    KANELLITSAS, C
    BLUE, T
    WANG, C
    CLENDENON, N
    FAIRCHILD, R
    LASTER, B
    MCGREGOR, J
    GOODMAN, J
    STRAHLENTHERAPIE UND ONKOLOGIE, 1989, 165 (2-3): : 229 - 230
  • [23] BORON NEUTRON-CAPTURE THERAPY - THE PAST TO THE PRESENT
    NAKAGAWA, Y
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1217 - 1217
  • [24] BORON NEUTRON-CAPTURE THERAPY OF CHOROIDAL MELANOMA
    MARCH, G
    PACKER, S
    CODERRE, J
    SVITRA, P
    GURZENDA, E
    HANSROTE, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1253 - 1253
  • [25] Beam shaping assembly design of Li(p,n) neutron source with a rotating target for boron neutron capture therapy
    Qiao, Zhaopeng
    Ma, Baolong
    Rong, Bo
    Jiang, Quanxu
    Wang, Sheng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1052
  • [26] DOSE PRESCRIPTION IN BORON NEUTRON-CAPTURE THERAPY
    GUPTA, N
    GAHBAUER, RA
    BLUE, TE
    WAMBERSIE, A
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1157 - 1166
  • [27] DESIGNING AN EPITHERMAL NEUTRON BEAM FOR BORON NEUTRON-CAPTURE THERAPY FOR A DIDO TYPE REACTOR USING MCNP
    ROSS, D
    CONSTANTINE, G
    WEAVER, DR
    BEYNON, TD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 334 (2-3): : 596 - 606
  • [28] A conceptual design of a beam-shaping assembly for boron neutron capture therapy based on deuterium-tritium neutron generators
    Martín, G
    Abrahantes, A
    MEDICAL PHYSICS, 2004, 31 (05) : 1116 - 1122
  • [29] NEUTRON-INDUCED GAMMA DOSE FROM A REACTOR BEAM FILTER FOR BORON NEUTRON-CAPTURE THERAPY
    HARRINGTON, BV
    PIGMENT CELL RESEARCH, 1989, 2 (04): : 246 - 253
  • [30] BEAM HOLE CONFIGURATION AND ANALYSIS OF MEDICAL REACTOR FOR BORON NEUTRON-CAPTURE THERAPY
    SASAKI, M
    HIROTA, J
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1995, 32 (02) : 142 - 153