Investigations on the stability of polarimetric fiber laser sensors in harsh environments

被引:0
|
作者
Frank, A [1 ]
Bohnert, K [1 ]
Haroud, K [1 ]
Brändle, H [1 ]
机构
[1] ABB Switzerland Ltd, Corp Res, CH-5405 Baden, Switzerland
来源
OPTICAL SENSING | 2004年 / 5459卷
关键词
fiber optic sensors; fiber laser; pressure sensor;
D O I
10.1117/12.543980
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The stability of a polarimetric Fabry-Perot fiber laser sensor for fluid pressure up to 100 MPa is investigated. The fluid acts on one of two elliptical-core fiber sections in the laser cavity producing a shift in the differential phase of the two orthogonal polarization modes and thus a variation in the beat frequencies of the corresponding longitudinal laser modes. The second fiber section, with a 90-degree offset in the core orientation, compensates for temperature-induced phase shifts. Dispersion in the birefringent fiber Bragg grating reflectors is employed to enhance the resolution of the sensor to a few parts in 10(6) of the free spectral range. Investigations on sensor stability address the effect of the fluid on the integrity of the fiber, creep caused by various types fiber coatings, as well as the intrinsic stability of erbium-doped and undoped sensing fibers under pressure and temperature changes. It is found that moisture-free silicone oil does not cause any fiber deterioration even in case of a bare fiber. Silicon nitride and gold coatings (1 mum thick) cause significant signal drift, whereas no drift is observed for carbon coatings. Highly doped elliptical-core sensing fiber exhibited drift in the differential optical phase while un-doped fiber did not.
引用
收藏
页码:295 / 302
页数:8
相关论文
共 50 条
  • [21] POLARIMETRIC FIBER LASER SENSORS USING ER-DOPED FIBER
    KIM, HK
    KIM, SK
    KIM, BY
    OPTICAL AND QUANTUM ELECTRONICS, 1995, 27 (05) : 481 - 485
  • [22] Fiber Bragg grating sensors in harsh environments: considerations and industrial monitoring applications
    Mendez, Alexis
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION X, 2017, 10329
  • [23] Radiation-Hardened Fiber Bragg Grating Based Sensors for Harsh Environments
    Morana, A.
    Girard, S.
    Marin, E.
    Perisse, J.
    Genot, J. S.
    Kuhnhenn, J.
    Grelin, J.
    Hutter, L.
    Melin, G.
    Lablonde, L.
    Robin, T.
    Cadier, B.
    Mace, J. -R.
    Boukenter, A.
    Ouerdane, Y.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (01) : 68 - 73
  • [24] The use of sensors systems in harsh environments
    Lasseur, J
    TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 1997, : 29 - 32
  • [25] Miniaturized Resonant Sensors for Harsh Environments
    Schmidtchen, Silja
    Richter, Denny
    Sauerwald, Jan
    Fritze, Holger
    MICRO- AND NANOTECHNOLOGY SENSORS, SYSTEMS, AND APPLICATIONS V, 2013, 8725
  • [26] Ceramic temperature sensors for harsh environments
    Gregory, OJ
    You, T
    IEEE SENSORS JOURNAL, 2005, 5 (05) : 833 - 838
  • [27] Sensors measure pH in harsh environments
    不详
    HYDROCARBON PROCESSING, 2003, 82 (02): : 31 - 32
  • [28] Thermal Flow Sensors for Harsh Environments
    Balakrishnan, Vivekananthan
    Hoang-Phuong Phan
    Toan Dinh
    Dzung Viet Dao
    Nam-Trung Nguyen
    SENSORS, 2017, 17 (09)
  • [29] Sensors for Extreme Harsh Environments Introduction
    Senesky, Debbie G.
    Dekate, Sachin
    SENSORS FOR EXTREME HARSH ENVIRONMENTS, 2014, 9113
  • [30] FIBER POLARIMETRIC STRESS SENSORS
    CHUA, TH
    CHEN, CL
    APPLIED OPTICS, 1989, 28 (15): : 3158 - 3165