Implementation of a vascular access quality programme improves vascular access care

被引:16
|
作者
van Loon, M.
van der Mark, W.
Beukers, N.
de Bruin, C.
Blankestijn, P. J.
Huisman, R. M.
Zijlstra, J. J.
van der Sande, F. M.
Tordoir, J. H. M.
机构
[1] Univ Hosp Masstricht, Dept Surg, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Masstricht, Dept Surg & Nephrol, NL-6202 AZ Masstricht, Netherlands
[3] Univ Med Ctr Utrecht, Dept Nephrol, Utrecht, Netherlands
[4] Univ Groningen Hosp, Dept Radiol, Groningen, Netherlands
[5] Hospital Midden Twente Hengelo, Hengelo, Netherlands
关键词
arteriovenous fistula; preemptive; intervention; surveillance; vascular access;
D O I
10.1093/ndt/gfm076
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Introduction. In the Netherlands an access quality improvement plan (QIP) was introduced by vascular access coordinators (VAC) with the aim to decrease vascular access-related complications by preemptive intervention of malfunctioning accesses. A vascular access QIP was established in 24 centres (46% of all Dutch facilities) and a structural multidisciplinary vascular access meeting was instituted. In these centres, including 2300 patients, a protocol for enhancement of fistula creation and access surveillance programme was implemented, with instruction of physicians and nurses, and rounds to discuss complications and evaluate vascular access interventions. The number and type of vascular access, permanent catheters, thrombosis rates and number of interventions were evaluated at the start and end of the study period. Results. After the surveillance programme, the number of autogenous arterio-venous fistulas (AVFs) had increased significantly from 69 to 77% (P < 0.01), while the use of temporary subclavian vein catheters declined (34% vs 11%) (P < 0.01), with a substantially higher percentage of jugular vein catheters (from 23 to 35%). Interventional treatment of malfunctioning accesses by percutaneous transluminal angioplasty (PTA) (from 0.39 to 0.50 patient/year; P < 0.001) and surgical revisions (from 0.06 to 0.12 per patient/year; P < 0.001) also increased. Conclusion. These data demonstrate that a vascular access QIP resulted in placement of more autogenous AVFs, increased number of PTAs and surgical interventions. These findings suggest that a vascular access care QIP is worthwhile to improve dialysis patients' care and access morbidity.
引用
收藏
页码:1628 / 1632
页数:5
相关论文
共 50 条
  • [21] Vascular Access
    不详
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2024, 83 (04) : S380 - S396
  • [22] Vascular Access
    Yelken, Berna
    Sever, Mehmet Sukru
    [J]. TURKISH NEPHROLOGY DIALYSIS AND TRANSPLANTATION JOURNAL, 2011, 20 (03): : 209 - 213
  • [23] Vascular Access
    不详
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2023, 81 (03) : S321 - S336
  • [24] Vascular Access
    Beathard, Gerald A.
    [J]. SEMINARS IN DIALYSIS, 2011, 24 (05) : 503 - 507
  • [25] Vascular access
    King, D
    Conway, EE
    [J]. PEDIATRIC ANNALS, 1996, 25 (12): : 693 - 698
  • [26] Vascular Access
    不详
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2021, 77 (04) : S249 - S265
  • [27] Vascular access
    Schwab, S
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 37 (01) : 190 - 191
  • [28] How Implementation Science Improves Access to Care
    Silberberg, Donald
    Sturke, Rachel
    Bergen, Donna
    [J]. NEUROLOGY, 2016, 86
  • [29] Vascular access
    Brouwer, DJ
    [J]. DIALYSIS & TRANSPLANTATION, 1997, 26 (12) : 835 - &
  • [30] Vascular access
    Leitch, RE
    Ouwendyk, M
    Lindsay, RM
    [J]. DAILY AND NOCTURNAL HEMODIALYSIS, 2004, 145 : 48 - 54