Minimization of Position Uncertainty Using 3-D Stereo Imaging Technique for the Real-Time Positioning of a Handheld Breast Tissue Anomaly Detection Probe

被引:0
|
作者
Grewal, Parvind K. [1 ]
Viswanath, K. S. [2 ]
Golnaraghi, Farid [1 ]
机构
[1] Simon Fraser Univ, Sch Engn Sci, Surrey, BC V3T 0A3, Canada
[2] Indian Inst Technol, Engn Design, Madras 600036, Tamil Nadu, India
关键词
Triangulation; Position uncertainty; Fiducial point; Intrinsic and Extrinsic Parameters;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
There is an associated position uncertainty while determining the position of a handheld diagnostic probe used to detect anomaly present in tissue; this uncertainty is overcome by finding the position and orientation of the diagnostic probe with respect to a reference. A diagnostic probe determines various anatomical parameters but the obtained results are not associated with a position to be compared in time domain. Time domain comparison of anatomical changes helps in pathological findings. For differential comparison, relative position of data collection point with respect to the patient position needs to be the same on different examination days. This paper presents an overview on the work done in overcoming this uncertainty of the position in a hand held probe with respect to the human body. A cost-effective binocular vision system is used to help provide the position information; the method consists of using reference markers and tracking the position and orientation of these reference markers present on the probe. The paper introduces a 3-D stereo imaging technique to determine position of the data collecting point in real time and reconstruct the surface of the patient phantom. The associated error in position determination has been close to 2.5 mm. Yet not clinically tested, this tracking system can be used as a cost effective solution to determine diagnostic hand held probe position information for differential comparison; by installing two to four digital cameras in the examination room.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Use of the apical sound window involves tangential cuts of the left ventricle:: Proof of the hypothesis using real-time 3-D imaging and volumetry
    Bartel, T
    Müller, S
    Katz, MA
    Erbel, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 468A - 468A
  • [42] Evaluation of the accuracy of a new semiautomatic 3-D program (PMAP) by quantifying right ventricular volume using real-time 3-D imaging: Studies in an in vitro model duplicating human RV anatomy
    Oie, LSL
    Schindera, ST
    Li, XK
    Mehwald, PS
    Kuo, J
    Castellucci, J
    von Ramm, OT
    Kececioglu, D
    Sahn, DJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 408A - 408A
  • [43] Real-Time Imaging for 3D Localization of Catheters, Needles and Brachytherapy Seeds Within the Soft Tissue Using X-Ray Induced Ultrasonic Imaging
    Yousefi, S.
    Tzousmas, S.
    Peng, H.
    Xing, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3092 - 3092
  • [44] Facial orientation and eye-gaze detection based on real-time 3D facial imaging by using correlation image sensor
    Zhan, Shu
    Kurihara, Toru
    Ando, Shigeru
    ISDA 2006: SIXTH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS DESIGN AND APPLICATIONS, VOL 2, 2006, : 1061 - +
  • [45] Simple and easy quantitation of functional mitral valve area using novel automated flow measurement technique with real-time 3-D color Doppler echocardiography
    Watanabe N.
    Nishino S.
    Shibata Y.
    Journal of Echocardiography, 2018, 16 (4) : 189 - 191
  • [46] Real-Time High-Resolution 3D Imaging Method Using 2D Phased Arrays Based on Sparse Synthetic Focusing Technique
    Kim, Jung-Jun
    Song, Tai-Kyong
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 1995 - 1998
  • [47] 3-D Real-Time Volumetric Imaging Using 20 MHz 1.5-mm Diameter Single-Chip CMUT-on-CMOS Array
    Tekes, Coskun
    Gurun, Gokce
    Rashid, Muhammad W.
    Zahorian, Jaime
    Xu, Toby
    Hasler, Jennifer
    Degertekin, F. Levent
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012,
  • [48] Real-time 3D display system based on computer-generated integral imaging technique using enhanced ISPP for hexagonal lens array
    Kim, Do-Hyeong
    Erdenebat, Munkh-Uchral
    Kwon, Ki-Chul
    Jeong, Ji-Seong
    Lee, Jae-Won
    Kim, Kyung-Ah
    Kim, Nam
    Yoo, Kwan-Hee
    APPLIED OPTICS, 2013, 52 (34) : 8411 - 8418
  • [49] Fast, automated, real-time 3D passive balloon catheter tracking during MRI-guided cardiac catheterization using orthogonal projection imaging and real-time image-based catheter detection
    Kowalik, Grzegorz T.
    Kerfoot, Eric
    Kunze, Karl
    Neji, Radhouene
    Moon, Tracy
    Mellor, Nina
    Razavi, Reza
    Pushparajah, Kuberan
    Roujol, Sebastien
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (01) : 311 - 320
  • [50] Comprehensive Evaluation of a Real-Time 3D MR Imaging Technique Using a Deformation-Driven Deep Convolutional Neural Network (KS-RegNet)
    Shao, H.
    Li, T.
    Dohopolski, M.
    Wang, J.
    Cai, J.
    Tan, J.
    Wang, K.
    Zhang, Y.
    MEDICAL PHYSICS, 2022, 49 (06) : E261 - E261