Fully automated treatment planning for head and neck radiotherapy using a voxel-based dose prediction and dose mimicking method

被引:145
|
作者
McIntosh, Chris [1 ,3 ]
Welch, Mattea [1 ,5 ]
McNiven, Andrea [1 ,2 ]
Jaffray, David A. [1 ,2 ,3 ,4 ,5 ]
Purdie, Thomas G. [1 ,2 ,3 ]
机构
[1] UHN, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[3] UHN, TECHNA Inst, Toronto, ON, Canada
[4] Univ Toronto, IBBME, Toronto, ON, Canada
[5] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 15期
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
automated treatment planning; machine learning; random forests; atlas-selection; knowledge-based planning; dose prediction; external beam radiotherapy; KNOWLEDGE-BASED PREDICTION; RADIATION-THERAPY; QUALITY; CANCER;
D O I
10.1088/1361-6560/aa71f8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present a probabilistic, atlas-based approach which predicts the dose for novel patients using a set of automatically selected most similar patients (atlases). The output is a spatial dose objective, which specifies the desired doseper-voxel, and therefore replaces the need to specify and tune dose-volume objectives. Voxel-based dose mimicking optimization then converts the predicted dose distribution to a complete treatment plan with dose calculation using a collapsed cone convolution dose engine. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients by evaluating 14 clinical dose evaluation criteria. Our preliminary results are promising and demonstrate that automated methods can generate comparable dose distributions to clinical. Overall, automated plans achieved an average of 0.6% higher dose for target coverage evaluation criteria, and 2.4% lower dose at the organs at risk criteria levels evaluated compared with clinical. There was no statistically significant difference detected in high-dose conformity between automated and clinical plans as measured by the conformation number. Automated plans achieved nine more unique criteria than clinical across the 12 patients tested and automated plans scored a significantly higher dose at the evaluation limit for two high-risk target coverage criteria and a significantly lower dose in one critical organ maximum dose. The novel dose prediction method with dose mimicking can generate complete treatment plans in 12-13 min without user interaction. It is a promising approach for fully automated treatment planning and can be readily applied to different treatment sites and modalities.
引用
收藏
页码:5926 / 5944
页数:19
相关论文
共 50 条
  • [21] Adaptive Radiotherapy of Head and Neck Cancer: Re-Planning Based On Prior Dose
    Dogan, N.
    Padgett, K.
    Evans, J.
    Sleeman, W.
    Song, S.
    Fatyga, M.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3279 - 3279
  • [22] Absorbed dose estimates to structures of the brain and head using a high-resolution voxel-based head phantom
    Evans, JF
    Blue, TE
    Gupta, N
    [J]. MEDICAL PHYSICS, 2001, 28 (05) : 780 - 786
  • [23] Evaluation of Automated Treatment Planning and Organ Dose Prediction for Lung Stereotactic Body Radiotherapy
    Ouyang, Zi
    Zhuang, Tingliang
    Marwaha, Gaurav
    Kolar, Matthew D.
    Qi, Peng
    Videtic, Gregory M.
    Stephans, Kevin L.
    Xia, Ping
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (10)
  • [24] Establishment and application of voxel-by-voxel-based objective dose in optimizing radiotherapy planning
    Chen, Bingzhou
    Zou, Lian
    Hou, Qing
    [J]. He Jishu/Nuclear Techniques, 2008, 31 (05): : 369 - 373
  • [25] Method for Voxel-Based Numerical Calculations of Biologically Effective Dose (BED)
    Gustafsson, J.
    Gleisner, K. Sjogreen
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S305 - S305
  • [26] Beam-wise dose composition learning for head and neck cancer dose prediction in radiotherapy
    Teng, Lin
    Wang, Bin
    Xu, Xuanang
    Zhang, Jiadong
    Mei, Lanzhuju
    Feng, Qianjin
    Shen, Dinggang
    [J]. MEDICAL IMAGE ANALYSIS, 2024, 92
  • [27] Documenting Dose Delivery for Head & Neck Radiotherapy Using a GPU Based Framework
    Santhanam, A.
    Neylon, J.
    Qi, S.
    Staton, R.
    Sheng, K.
    Low, D.
    Kupelian, P.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [28] Voxel-based Analysis of Dose for Toxicity Prediction in Prostate Cancer Radiation Therapy
    Drean, G.
    Acosta, O.
    Arango, J. Ospina
    Simon, A.
    Cazoulat, G.
    Haigron, P.
    Gnep, K.
    Zhu, J.
    Henry, O.
    de Crevoisier, R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S386 - S387
  • [29] Effect of voxel size on Monte Carlo dose calculations for radiotherapy treatment planning
    Mora, G
    Pawlicki, T
    Maio, A
    Ma, CM
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 549 - 554
  • [30] Optimization Towards Dose Carving for Head and Neck Treatment Planning
    Ruan, Dan
    Sayre, George
    Low, Daniel A.
    [J]. CURRENT CANCER THERAPY REVIEWS, 2014, 10 (04) : 334 - 342