Insulation diagnostic technique to assess the condition of generator winding by measuring microwave associated with dielectric breakdown

被引:2
|
作者
Kawada, M [1 ]
Kawasaki, ZI
Matsuura, K
机构
[1] Nagoya Inst Technol, Nagoya, Aichi 4668555, Japan
[2] Osaka Univ, Suita, Osaka 565, Japan
关键词
D O I
10.1109/60.849111
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Partial Discharge (PD) occurring in the insulation of the stator winding of the generator is a symptom of the deterioration of the insulation system. PD is a very short duration current and/or voltage pulse, about 1-5 ns, Generally PD emits broad band electromagnetic wave (similar to GHZ), We developed a new system for detecting the microwave emitted from PD, From the point of view of predicting an accident caused by the insulation breakdown of the generator winding, it is important to assess the condition of the winding, We applied our system to a dielectric breakdown test to know the relation between the characteristics of the microwave and the condition of the insulation system of the winding. The dielectric breakdown test is useful for estimating the minimum breakdown voltage which is a criterion of the insulation condition of the winding. Experimental results showed that this system was able to assess the insulation condition by measuring the number of the pulses of microwave frequency per voltage cycle.
引用
收藏
页码:19 / 23
页数:5
相关论文
共 36 条
  • [1] Diagnostic technique to assess the condition of stator insulation by measuring microwave associated with dielectric breakdown
    Kawada, M
    Kawasaki, ZI
    Matsuura, K
    CONFERENCE RECORD OF THE 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1998, : 249 - 252
  • [2] Insulation diagnosis method for generator winding by measuring microwaves associated with dielectric breakdown
    Kawada, M
    Kawasaki, Z
    Matsu-ura, K
    Musashiya, T
    Kuroki, S
    Osawa, T
    Tanaka, H
    ELECTRICAL ENGINEERING IN JAPAN, 2000, 132 (01) : 38 - 45
  • [3] Insulation diagnosis method for generator winding by measuring microwaves associated with dielectric breakdown
    Kawada, Masatake
    Kawasaki, Zen-Ichiro
    Matsu-Ura, Kenji
    Musashiya, Toshio
    Kuroki, Satoru
    Osawa, Teruya
    Tanaka, Hiroki
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 2000, 132 (01): : 38 - 45
  • [4] FLOWCHART PROCEDURE TO ASSESS THE CONDITION OF TURBINE GENERATOR INSULATION
    STONE, GC
    CULBERT, I
    DHIRANI, H
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1990, 5 (03) : 546 - 552
  • [5] GENERATOR FOR MEASURING TIME LAG OF DIELECTRIC BREAKDOWN
    BUTLER, LA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1965, 36 (11): : 1660 - &
  • [6] Study on the characteristic parameters used to assess the insulation condition of stator winding
    Yue, B
    Zhu, ZL
    Chen, XL
    Xie, HK
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 278 - 280
  • [7] Condition Assessment of Generator Insulation using Diagnostic Tests
    Chophel, Tenzin
    Suwanasri, Thanapong
    Suwanasri, Cattareya
    2019 7TH INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON 2019), 2019,
  • [8] Condition Evaluation of Stator Winding Insulation of Vintage High Voltage Turbine Generator
    Kumar, P. G. S.
    Reddy, K. Malla
    2015 IEEE INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND COMMUNICATION TECHNOLOGIES, 2015,
  • [9] A MICROWAVE DIELECTRIC LOSS MEASURING TECHNIQUE
    MACLEAN, WR
    JOURNAL OF APPLIED PHYSICS, 1946, 17 (07) : 558 - 566
  • [10] NUMERICAL STUDY OF MICROWAVE DIELECTRIC SURFACE BREAKDOWN AT ATMOSPHERIC CONDITION
    Zhou, Qianhong
    Dong, Ye
    Dong, Zhiwei
    2015 42ND IEEE INTERNATIONAL CONFERENCE ON PLASMA SCIENCES (ICOPS), 2015,