Common-path intrinsically achromatic optical diffraction tomography

被引:15
|
作者
Zdankowski, Piotr [1 ]
Winnik, Julianna [1 ]
Patorski, Krzysztof [1 ]
Goclowski, Pawel [1 ]
Ziemczonok, Michal [1 ]
Jozwik, Michal [1 ]
Kujawinska, Malgorzata [1 ]
Trusiak, Maciej [1 ]
机构
[1] Warsaw Univ Technol, Inst Micromech & Photon, 8 Sw A Boboli St, PL-02525 Warsaw, Poland
关键词
REFRACTIVE-INDEX TOMOGRAPHY; PHASE MICROSCOPY PRINCIPLES; QUANTITATIVE PHASE; HOLOGRAPHIC TOMOGRAPHY; 3-BEAM INTERFERENCE; INTERFEROMETRY; RECONSTRUCTION; CELLS; INTENSITY; ROTATION;
D O I
10.1364/BOE.428828
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantitative phase microscopy (QPM) [1-4] is gaining a lot of interest, as it provides measurable information about phase distribution of the tested semi-transparent object, without the need of staining the sample. It showed its powerful imaging capabilities in plethora of applications, e.g., biomedicine [5], neuroscience [6], blood and flow cytometry [7,8] or cell pathophysiology [9]. The label-free imaging is achieved thanks to the intrinsic contrast of transparent (phase) samples - each component of the sample introduces different optical delay to the light. However, QPM imaging only delivers an averaged phase delay (along the Z axis), losing the information about internal structure of the imaged object. Additionally, phase delay (optical thickness) can change due to the local variation of both refractive index and physical thickness of the sample. Therefore, In this work we propose an open-top like common-path intrinsically achromatic optical diffraction tomography system. It operates as a total-shear interferometer and employs Ronchi-type amplitude diffraction grating, positioned in between the camera and the tube lens without an additional 4f system, generating three-beam interferograms with achromatic second harmonic. Such configuration makes the proposed system low cost, compact and immune to vibrations. We present the results of the measurements of 3D-printed cell phantom using laser diode (coherent) and superluminescent diode (partially coherent) light sources. Broadband light sources can be naturally employed without the need for any cumbersome compensation because of the intrinsic achromaticity of the interferometric recording (holograms generated by -1st and +1st conjugated diffraction orders are not affected by the illumination wavelength). The results show that the decreased coherence offers much reduced coherent noise and higher fidelity tomographic reconstruction especially when applied nonnegativity constraint regularization procedure.
引用
收藏
页码:4219 / 4234
页数:16
相关论文
共 50 条
  • [21] Fourier Domain Common-Path Optical Coherence Tomography with a Conduit Fiber Bundle Probe
    Han, Jae-Ho
    Liu, Xuan
    Song, Chul Gyu
    Kang, Jin U.
    2009 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1AND 2, 2009, : 205 - 206
  • [22] Common-path optical heterodyne profilometer: a configuration
    Chou, C
    Shyu, JC
    Huang, YC
    Yuan, CK
    APPLIED OPTICS, 1998, 37 (19): : 4137 - 4142
  • [23] Common-path achromatic interferometer-coronagraph: Images from a breadboard demonstrator
    Tavrov, Alexander V.
    Nishikawa, Jun
    Tamura, Motohide
    Abe, Lyu
    Yokochi, Kaito
    Kurokawa, Takashi
    Takeda, Mitsuo
    APPLIED OPTICS, 2007, 46 (28) : 6885 - 6895
  • [25] Achromatic coronagraph based on out-of-plane common-path nulling interferometer
    Tavrov, AV
    Tanaka, Y
    Shioda, T
    Kurokawa, T
    Takeda, M
    NEW FRONTIERS IN STELLAR INTERFEROMETRY, PTS 1-3, 2004, 5491 : 824 - 830
  • [26] Reference optimization for a common-path optical coherence tomography probe using angle polishing
    Liu, Xuan
    Kang, Jin U.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [27] Common-path optical coherence tomography with side-viewing bare fiber probe for endoscopic optical coherence tomography
    Sharma, Utkarsh
    Kang, Jin U.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (11):
  • [28] Common-path optical coherence tomography guided fibre probe for spatially precise optical nerve stimulation
    Zhang, K.
    Katz, E.
    Kim, D. H.
    Kang, J. U.
    Ilev, I. K.
    ELECTRONICS LETTERS, 2010, 46 (02) : 118 - 119
  • [29] Common-path OCT using optical delay stair
    Wang, Yi
    Chen, Xiaodong
    Leng, Ji
    Wang, Ting
    Chen, Xiaojie
    Li, Junwei
    Yu, Daoyin
    Chinese Optics Letters, 2015, 13
  • [30] Common-path optical coherence tomography using Bessel beam axicon probe for malignancy identification
    Gupta, P.
    Vairagi, K.
    Sharma, V.
    Prasad, K. K.
    Mondal, S. K.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXVII, 2023, 12367