Low-cost wireless smart device design for radiation protection and nuclear security

被引:4
|
作者
Taamte, J. Mbarndouka [1 ,2 ]
Saidou [1 ,3 ]
Bodo, B. [2 ]
Noube, M. Kountchou [1 ]
Signing, V. R. Folifack [1 ]
Younui, S. Yakum-Ntaw [1 ]
Yerima, A. Hamadou [1 ]
Iamsumang, C. [4 ]
Massey, C. [4 ]
机构
[1] Res Ctr Nucl Sci & Technol, Inst Geol & Min Res, P.O. Box 4110, Yaounde, Cameroon
[2] Univ Yaounde I, Fac Sci, Dept Phys, Lab Elect & Elect Syst, Yaounde, Cameroon
[3] Univ Yaounde I, Fac Sci, Nucl Phys Lab, P.O. Box 812, Yaounde, Cameroon
[4] Int Atom Energy Agcy IAEA, Dept Nucl Safety & Secur, Vienna, Austria
关键词
Analogue electronic circuits; Counting gases and liquids; Detector alignment and calibration methods (lasers; sources; particle-beams); Radiation monitoring; CONSEQUENCES;
D O I
10.1088/1748-0221/16/06/T06011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article presents the realization and implementation of a low-cost intelligent electronic device, which detects the ambient dose rate of Gamma and Beta ionizing radiation in real-time. Developed according to the principle of nuclear analog signal processing, the device uses a Geiger-Muller tube detector, in which the electronic circuit has been readjusted to produce the standard radiation protection signal (a slow positive logic pulses). It also consists of low-cost components such as the Atmega328P microcontroller board and XBee wireless modules for environmental radiation and nuclear security monitoring. The proposed device has several advantages, namely low energy consumption, low-cost, easily deployable in the field (in-situ), adapted for realtime measurements and data transmission to a remote personal computer (PC). After calibration using Cesium (Cs-137), a comparative analysis of the data obtained from the proposed dosimeter was carried out with those of an in-situ gamma spectrometry chain (reference method) previously used at the same place and under the same conditions. This analysis gave an acceptable mean value of 64.30 nGy/h, of the proposed device, compared to that of the gamma spectrometer, which is 50.67 nGy/h. The prototype thus developed is simple, precise, and made for radiation protection.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Development of a Low-Cost Device for Measuring Ultraviolet Solar Radiation
    Serrano, Antonio
    Abril-Gago, Jesus
    Garcia-Orellana, Carlos J.
    FRONTIERS IN ENVIRONMENTAL SCIENCE, 2022, 9
  • [22] Low-cost Extendable Framework for Embedded Smart Car Security System
    Xiao, Jian
    Feng, Haidong
    2009 IEEE INTERNATIONAL CONFERENCE ON NETWORKING, SENSING AND CONTROL, VOLS 1 AND 2, 2009, : 819 - 823
  • [23] Practical attacks on security and privacy through a low-cost android device
    University of Strathclyde Department, Electronic and Electrical Engineering, Glasgow, United Kingdom
    J. Cyber Secur. Mobil., 2-3 (33-52):
  • [24] Low-Cost Smart Refrigerator
    Wu, Hsin-Han
    Chuang, Yung-Ting
    2017 IEEE 1ST INTERNATIONAL CONFERENCE ON EDGE COMPUTING (IEEE EDGE), 2017, : 228 - 231
  • [25] Wireless Low-Cost Bioimpedance Measurement Device for Lung Capacity Screening
    Pino, Esteban J.
    Gomez, Britam
    Monsalve, Emyrna
    Aqueveque, Pablo
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 1187 - 1190
  • [26] Design and Development of Low-cost Smart Training Pants (STants)
    Salehi, Sarvenaz
    Bleser, Gabriele
    Stricker, Didier
    2014 EAI 4TH INTERNATIONAL CONFERENCE ON WIRELESS MOBILE COMMUNICATION AND HEALTHCARE (MOBIHEALTH), 2014, : 51 - 54
  • [27] Low-Power Low-Cost Wireless Flood Sensor for Smart Home Systems
    Teixido, Pedro
    Antonio Gomez-Galan, Juan
    Gomez-Bravo, Fernando
    Sanchez-Rodriguez, Trinidad
    Alcina, Javier
    Aponte, Juan
    SENSORS, 2018, 18 (11)
  • [28] Design of a Low-Cost Wireless Surface EMG Acquisition System
    Fu, Jianting
    Chen, Jian
    Shi, Yizhi
    Li, Yao
    2013 6TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2013, : 699 - 702
  • [29] A low-cost spacer device
    Gordon, S
    TROPICAL DOCTOR, 1999, 29 (02) : 116 - 116
  • [30] LOW-COST HOSPITALIZATION PROTECTION
    Bjorn, Walter
    HARVARD BUSINESS REVIEW, 1944, 22 (02) : 256 - 264