Study on effect of liquid level on the heat leak into vertical cryogenic vessels

被引:13
|
作者
Li, Yang [1 ]
Wang, Rongshun [1 ]
Wang, Caili [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen Engn, Shanghai 200240, Peoples R China
关键词
Liquid level; Heat leak; Cryogenic vessels; Experimental; Finite element method; TRANSFERS; TANK;
D O I
10.1016/j.cryogenics.2009.12.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
The diminishing of heat leak into cryogenic vessels can prolong the storage time of cryogenic liquid. With the storage of cryogenic liquid reducing, the heat leak decreases, while the actual storage time increases. Compared with the theoretical analysis, the numerical simulation can more accurately calculate the heat transfer and temperature distribution in the vessel with complex structure. In this paper the steady state heat leak into cryogenic vessels with different liquid level height is analyzed using a finite element model. And liquid nitrogen boil-off method was adopted in experiments to validate the result of numerical simulation. Experimental results indicate favorable agreement with numerical simulation by ANSYS software. The effect of liquid level on heat leak into the cryogenic vessel can be considered in calculation of storage time and structure design. (C) 2010 Published by Elsevier Ltd.
引用
收藏
页码:367 / 372
页数:6
相关论文
共 50 条
  • [41] GEYSERING OF A CRYOGENIC LIQUID FROM AN OPEN VERTICAL TUBE.
    Shugan, I.V.
    Bosykh, L.A.
    Moscow University mechanics bulletin, 1980, 35 (5-6) : 36 - 40
  • [42] THE EFFECT OF THE IMPELLER DIAMETER ON THE HEAT-TRANSFER IN AGITATED VESSELS PROVIDED WITH VERTICAL TUBE BAFFLES
    HAVAS, G
    DEAK, A
    SAWINSKY, J
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1983, 27 (03): : 197 - 198
  • [43] Study on Calculation of Liquid Level And Storage of Tanks for LNG-fueled Vessels
    Li, Kun
    Wang, Guoqing
    Liu, Chang
    2017 INTERNATIONAL CONFERENCE ON ADVANCED ENVIRONMENTAL ENGINEERING (ICAEE2017), 2018, 111
  • [44] Investigating the effect of metal-polymer internal support on reducing the heat transfer rate of mobile cryogenic vessels
    Vahid Norouzifard
    Seyed Meysam Hosseini
    Ebrahim Alizadeh
    Heat and Mass Transfer, 2021, 57 : 269 - 282
  • [45] Control of liquid level in vessels under pressure
    McMahon, JB
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1937, 29 : 1219 - 1224
  • [46] Investigating the effect of metal-polymer internal support on reducing the heat transfer rate of mobile cryogenic vessels
    Norouzifard, Vahid
    Hosseini, Seyed Meysam
    Alizadeh, Ebrahim
    HEAT AND MASS TRANSFER, 2021, 57 (02) : 269 - 282
  • [47] An HTS Electronic Unit for Cryogenic Liquid Level Measurement
    I. A. Arkharov
    V. Yu. Emel'yanov
    Chemical and Petroleum Engineering, 2002, 38 : 24 - 27
  • [48] A FAIL SAFE CRYOGENIC LIQUID-LEVEL CONTROLLER
    REGAN, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 236 (01): : 206 - 210
  • [49] The Liquid Nitrogen Level Measurement for Cryogenic Fuel Tank
    Wang, Tao
    Wang, Limin
    Wang, Zhicheng
    Liu, Yubei
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON TEST, MEASUREMENT AND COMPUTATIONAL METHODS (TMCM 2015), 2015, 26 : 59 - 61
  • [50] FAIL SAFE CRYOGENIC LIQUID LEVEL CONTROLLER.
    Regan, Thomas