A computational study on vascular damage caused by shape memory alloy self-expandable and balloon-expandable stents in a stenosed artery

被引:7
|
作者
Rouhani, Fatemeh [1 ]
Fereidoonnezhad, Behrooz [2 ]
Zakerzadeh, Mohammad Reza [1 ]
Baghani, Mostafa [1 ]
机构
[1] Univ Tehran, Coll Engn, Sch Mech Engn, POB 11155-4563, Tehran, Iran
[2] Natl Univ Ireland, Dept Biomed Engn, Galway, Ireland
关键词
Stent; shape memory alloy; self-expandable; balloon-expandable; artery; inelastic; damage; finite element; FINITE-ELEMENT-ANALYSIS; PERMANENT DEFORMATION; 3-DIMENSIONAL MODEL; CONSTITUTIVE MODEL; NITINOL STENT; EXPANSION; FATIGUE; DESIGN; SIMULATION; STAINLESS;
D O I
10.1177/1045389X19880021
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Atherosclerosis is one of the major types of cardiovascular diseases. Stent deployment into the stenosed artery is the most common treatment for atherosclerosis. Two common stent models based on two different expansion principles are balloon-expandable and self-expandable stents. Depending on the modality of the expansion, the material used for these two stents varies. Despite the extensive progress made in the field of stent construction, plaque fragmentation and in-stent restenosis are two of the problems that still cause complications in stenting. Computational modeling and finite element method help us predict the damage effects to the artery and plaque in the stenting process. In this article, we simulate the insertion of two stents (the stainless steel stent and the shape memory alloy stent) in a diseased artery with real geometry. Results are compared to account for the effects of these stents on the artery, especially, the maximum stress in the plaque and arterial layers and surgically induced damage as the main cause of plaque fracture during the stent deployment and in-stent restenosis. It is found that arising from superelasticity, the shape memory alloy stent induces less damage to the artery. In addition, the stress created in the artery by the shape memory alloy stent is smaller. Therefore, the risk of plaque fragmentation and in-stent restenosis is reduced in shape memory alloy stents.
引用
收藏
页码:3113 / 3123
页数:11
相关论文
共 50 条
  • [21] Comparison of latest generation transfemoral self-expandable and balloon-expandable transcatheter heart valves
    Schaefer, Andreas
    Linder, Matthias
    Seiffert, Moritz
    Schoen, Gerhard
    Deuschl, Florian
    Schofer, Niklas
    Schneeberger, Yvonne
    Blankenberg, Stefan
    Reichenspurner, Hermann
    Schaefer, Ulrich
    Conradi, Lenard
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 25 (06) : 905 - 911
  • [22] Aortic Angulation Attenuates Procedural Success Following Self-Expandable But Not Balloon-Expandable TAVR
    Abramowitz, Yigal
    Maeno, Yoshio
    Chakravarty, Tarun
    Kazuno, Yoshio
    Takahashi, Nobuyuki
    Kawamori, Hiroyuki
    Mangat, Geeteshwar
    Cheng, Wen
    Jilaihawi, Hasan
    Makkar, Raj R.
    JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) : 964 - 972
  • [23] VASCULAR PATHOLOGY OF BALLOON-EXPANDABLE FLEXIBLE COIL STENTS IN HUMANS
    ANDERSON, PG
    BAJAJ, RK
    BAXLEY, WA
    ROUBIN, GS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) : 372 - 381
  • [24] A Novel Transcarotid Approach for Implantation of Balloon-Expandable or Self-Expandable Transcatheter Aortic Valves
    Campelo-Parada, Francisco
    Rodes-Cabau, Josep
    Dumont, Eric
    Del Trigo, Maria
    Regueiro, Ander
    Doyle, Daniel
    De Larochelliere, Robert
    Paradis, Jean-Michel
    Kalavrouziotis, Dimitri
    Mohammadi, Siamak
    CANADIAN JOURNAL OF CARDIOLOGY, 2016, 32 (12) : 1575.e9 - 1575.e12
  • [25] Treatment of pulmonary artery pseudoaneurysms and stenosis with balloon-expandable stents
    Imrie, Andrew
    Haran, Crishan, V
    Trotter, Michael
    Bell, Brendan
    Brown, Nicholas, I
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2022, 66 (07) : 969 - 976
  • [26] Comparative Efficacy and Safety of Self-Expandable vs. Balloon-Expandable Stent Grafts in Visceral Artery Aneurysm Management
    Talaie, Reza
    Torkian, Pooya
    Spano, Anthony
    Mahjoubnia, Alireza
    Flanagan, Siobhan M.
    Rosenberg, Michael
    Lin, Jian
    Golzarian, Jafar
    Shrestha, Preshant
    DIAGNOSTICS, 2024, 14 (15)
  • [27] A COMPARISON STUDY OF SELF-EXPANDABLE STENTS VS BALLOON ANGIOPLASTY ALONE IN FEMOROPOPLITEAL ARTERY OCCLUSIONS
    DO, DD
    TRILLER, J
    WALPOTH, BH
    STIRNEMANN, P
    MAHLER, F
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1992, 15 (05) : 306 - 312
  • [28] Bail-Out Implantation of an Embolized Balloon-Expandable Transcatheter Heart Valve in the Aortic Arch Using Self-Expandable Stents
    Dreger, Henryk
    Suendermann, Simon
    Niehues, Stefan M.
    Landmesser, Ulf
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 180 : 163 - 164
  • [29] Clinical outcomes of self-expandable vs. balloon-expandable TAVI for severe aortic stenosis
    Tham, Jodie Li Mei
    Adams, Heath
    Paleri, Sarang
    Wright, Christine
    Dimitriou, Jim
    Newcomb, Andrew
    MacIsaac, Andrew I.
    Whitbourn, Robert J.
    Palmer, Sonny C.
    ACTA CARDIOLOGICA, 2020, 75 (03) : 218 - 225
  • [30] Biocompatible Shape Memory Blend for Self-Expandable Stents with Potential Biomedical Applications
    Zheng, Yu
    Li, Ying
    Hu, Xue
    Shen, Jiabin
    Guo, Shaoyun
    ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (16) : 13988 - 13998