Automated non-invasive detection of pumping states in an implantable rotary blood pump

被引:0
|
作者
Karantonis, Dean M. [1 ]
Cloherty, Shaun L. [1 ]
Mason, David G. [1 ]
Salarnonsen, Robert F. [1 ]
Ayre, Peter J. [1 ]
Lovell, Nigel H. [1 ]
机构
[1] Univ New S Wales, Grad Sch Biomed Engn, Sydney, NSW 2052, Australia
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
With respect to rotary blood pumps used as left ventricular assist devices (LVADs), it is clinically important to control pump flow to avoid complications associated with overor under-pumping of the native heart. By employing only the non-invasive observer of instantaneous pump impeller speed to assess flow dynamics, a number of physiologically significant pumping states may be detected. Based on a number of acute animal experiments, five such states were identified: regurgitant pump flow (PR), ventricular ejection (VE), nonopening of the aortic valve (ANO), and partial collapse (intermittent and continuous) of the ventricle wall (PVC-I and PVC-C). Two broader states, normal (corresponding to VE, ANO) and suction (corresponding to PVC-I, PVC-C) were readily discernable in clinical data from human patients implanted with LVADs. Based on data from both the animal experiments (N = 6) and the human patients (N = 10), a strategy for the automated non-invasive detection of significant pumping states has been developed and validated. Employing a classification and regression tree (CART), this system detects pumping states with a high degree of accuracy: state VE 87.5/100.0% (sensitivity/specificity); state ANO - 98.1/92.5%; state PVC-1 - 90.0/90.2%; state PVC-C - 61.2/98.0%. With a simplified binary scheme differentiating suction and normal states, both states were detected without error in data from the animal experiments, and with a sensitivity/specificity, for detecting suction, of 99.2/98.3% in the human patient data.
引用
收藏
页码:4216 / +
页数:2
相关论文
共 50 条
  • [21] SUITABILITY OF THE FOREARM FOR AUTOMATED NON-INVASIVE BLOOD PRESSURE MEASUREMENT
    Rajan, N.
    Rao, S. L.
    [J]. ANESTHESIA AND ANALGESIA, 2014, 118 : S22 - S22
  • [22] Non-Invasive Sensor based Automated Smoking Activity Detection
    Bhandari, Babin
    Lu, JianChao
    Zheng, Xi
    Rajasegarar, Sutharshan
    Karmakar, Chandan
    [J]. 2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 845 - 848
  • [23] Noninvasive pulsatile flow estimation for an implantable rotary blood pump
    Karantonis, Dean M.
    Cloherty, Shaun L.
    Mason, David G.
    Ayre, Peter J.
    Lovell, Nigel H.
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1018 - +
  • [24] Impeller behavior and displacement of the VentrAssist implantable rotary blood pump
    Chung, MKH
    Zhang, N
    Tansley, TD
    Woodard, JC
    [J]. ARTIFICIAL ORGANS, 2004, 28 (03) : 287 - 297
  • [25] CAN WE DEVELOP A TOTALLY IMPLANTABLE ROTARY BLOOD PUMP
    NOSE, Y
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 561 - 562
  • [26] Non-invasive assessment of thromboembolism in rotary blood pumps-case study
    Gawlikowski, Maciej
    Kustosz, Roman
    Glowacki, Maciej
    Pydzinski, Pawel
    Kubacki, Krzysztof
    Zakliczynski, Michal
    Copik, Izabela
    Pacholewicz, Jerzy
    [J]. 12TH CONFERENCE ON INTEGRATED OPTICS: SENSORS, SENSING STRUCTURES, AND METHODS, 2017, 10455
  • [27] Implantable nanosensor for non-invasive ovarian cancer biomarker detection with wearable interface
    Heller, Daniel A.
    Williams, Ryan M.
    Levine, Douglas A.
    [J]. CANCER RESEARCH, 2019, 79 (13)
  • [28] Automated non-invasive measurement of blood pressure: Standardization of calibration procedures
    Balestrieri, E.
    Daponte, P.
    Rapuano, S.
    [J]. 2008 IEEE INTERNATIONAL WORKSHOP ON MEDICAL MEASUREMENTS AND APPLICATIONS, 2008, : 124 - +
  • [29] Research progress on minimally invasive and non-invasive blood glucose detection methods
    Gao X.
    Xu Z.
    Chen L.
    [J]. Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2023, 40 (02): : 365 - 372
  • [30] A Non-Invasive Physiological Control System of a Rotary Blood Pump Based on Preload Sensitivity: Use of Frank-Starling-Like Mechanism
    Wang, Fangqun
    Wang, Shaojun
    Li, Zhijian
    He, Chenyang
    Xu, Fan
    Jing, Teng
    [J]. MICROMACHINES, 2022, 13 (11)