摘要
Insamyangpye-tang (ISYPT) is a traditional medicinal formula comprised of 13 herbs and has been used in East Asia to treat lung-related diseases. However, to our knowledge, no method of analysis for its quality control has been reported. In this study, a method of analysis for quality control of ISYPT was developed using high-performance liquid chromatography. Chromatographic separation, analysis, and assay verification were performed with a distilled water-acetonitrile mobile phase system, both containing 0.1% (v/v) trifluoroacetic acid, and a Gemini C18 analytical column (4.6 mm x 250 mm, 5 mu m) using authentic standards for eight marker compounds. These marker constituents were detected simultaneously at 0.09-5.95 mg/g. The analysis method developed can be used for basic quality control of ISYPT.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Simultaneous determination of five marker compounds in Xuanfu Daizhe Tang by high-performance liquid chromatography coupled with diode array detection for quality control
    Qin, Kunming
    Wang, Bin
    Cai, Hao
    Li, Weidong
    Yao, Zhongqing
    Zhang, Xingde
    Lu, Tulin
    Cai, Baochang
    PHARMACOGNOSY MAGAZINE, 2012, 8 (32) : 250 - 255
  • [2] Determination of Atenolol and Trimetazidine in Pharmaceutical Tablets and Human Urine Using a High Performance Liquid Chromatography-Photo Diode Array Detection Method
    El-Alfy, Walaa
    Ismaiel, Omnia A.
    El-Mammli, Magda Y.
    Shalaby, Abdalla
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 2019
  • [3] Determination of nitrofuran metabolites in shrimp muscle by liquid chromatography-photo diode array detection
    Fernando, R.
    Munasinghe, D. M. S.
    Gunasena, A. R. C.
    Abeynayake, P.
    FOOD CONTROL, 2017, 72 : 300 - 305
  • [4] Determination of tetracycline, oxytetracycline and chlortetracycline residues in seafood products of Saudi Arabia using high performance liquid chromatography-Photo diode array detection
    Alanazi, Fatimah
    Almugbel, Rawan
    Maher, Hadir M.
    Alodaib, Faten M.
    Alzoman, Nourah Z.
    SAUDI PHARMACEUTICAL JOURNAL, 2021, 29 (06) : 566 - 575
  • [5] Determination of squalene using high-performance liquid chromatography with diode array detection
    Lu, HT
    Jiang, Y
    Chen, F
    CHROMATOGRAPHIA, 2004, 59 (5-6) : 367 - 371
  • [6] Determination of Squalene Using High-Performance Liquid Chromatography with Diode Array Detection
    Hai-Tao Lu
    Yue Jiang
    Feng Chen
    Chromatographia, 2004, 59 : 367 - 371
  • [7] Simultaneous determination of 9 preservatives in processed foods using high-performance liquid chromatography with photo diode array detector
    Lee, Do-Yeon
    Kim, Min-Hee
    Ahn, Jang-Hyuk
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2020, 33 (06): : 233 - 239
  • [8] Determination of levamisole in sheep muscle tissue by high-performance liquid chromatography and photo diode array detection
    Tyrpenou, AE
    Xylouri-Frangiadaki, EM
    CHROMATOGRAPHIA, 2006, 63 (7-8) : 321 - 326
  • [9] Determination of Levamisole in Sheep Muscle Tissue by High-Performance Liquid Chromatography and Photo Diode Array Detection
    A. E. Tyrpenou
    E. M. Xylouri-Frangiadaki
    Chromatographia, 2006, 63 : 321 - 326
  • [10] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC) USING DIODE-ARRAY DETECTION
    MICELI, JN
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1240 - 1240