Predictors of Clinical Outcome After Treatment of Intracranial Aneurysms with the Pipeline Embolization Device

被引:6
|
作者
Griffin, Andrew [1 ]
Reese, Vanessa [1 ]
Huseyinoglu, Zeynep [1 ]
Niedzwiecki, Donna [2 ]
Yang, Lexie [2 ]
Cutler, Andrew [1 ]
Gonzalez, L. Fernando [1 ]
Zomorodi, Ali [1 ]
Smith, Tony [1 ]
Hauck, Erik F. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Neurosurg, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Biostat, Durham, NC USA
关键词
Aneurysm; Pipeline embolization device; Stent; CEREBRAL ANEURYSMS; MULTICENTER; COMPLICATIONS;
D O I
10.1016/j.wneu.2019.06.185
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Flow-diverting stents have revolutionized the endovascular treatment of intracranial aneurysms. The purpose of this study is to identify predictors of adverse outcomes associated with the pipeline embolization device (PED). METHODS: A retrospective analysis of all patients treated with PED at a single high-volume center from January 2014 to September 2018. Patient outcomes, neurologic morbidity/mortality, and other clinical variables were analyzed. RESULTS: We treated 204 aneurysms in 170 patients with PED. Mean length of follow-up was 11 months. Most (181) aneurysms (89%) were located in the anterior circulation, and 23 (11%) were found in the posterior circulation. Most aneurysms were saccular (82%), followed by fusiform (11%), blister (4%), and dissecting pseudoaneurysms (3%). Mean aneurysm size was 8.2 + 5.7 mm with 145 (71%) small aneurysms (<= 10 mm), 53 (26%) large aneurysms (between 10 and 25 mm), and 6 (3%) giant aneurysms (>= 25 mm). Ninety-two percent of aneurysms were unruptured, and 8% were ruptured. The overall major neurologic morbidity/mortality was 4.7% and 1.8%, respectively. The all-cause mortality was 2.9%. Predictors of neurologic morbidity/mortality included the baseline modified Rankin Scale (P = 0.001), aneurysm neck size (P = 0.003), aneurysm size (P = 0.006), anterior versus posterior location (P = 0.02), and rupture at presentation (0.006). The P2Y12 Reactivity Unit, parent vessel diameter, and patient age did not correlate with adverse events. CONCLUSIONS: The PED has a satisfactory safety profile in both on- and off-label indications. A poor clinical patient baseline, wider aneurysm neck or larger size, and rupture predict an increased risk of an unfavorable outcome.
引用
收藏
页码:E666 / E671
页数:6
相关论文
共 50 条
  • [21] Aneurysms with persistent patency after treatment with the Pipeline Embolization Device
    Kan, Peter
    Srinivasan, Visish M.
    Mbabuike, Nnenna
    Tawk, Rabih G.
    Ban, Vin Shen
    Welch, Babu G.
    Mokin, Maxim
    Mitchell, Bartley D.
    Puri, Ajit
    Binning, Mandy J.
    Duckworth, Edward
    JOURNAL OF NEUROSURGERY, 2017, 126 (06) : 1894 - 1898
  • [22] Treatment of Intracranial Aneurysms With Pipeline Embolization Device: Newer Applications and Technical Advances
    Santosh B. Murthy
    Jharna Shah
    Halinder S. Mangat
    Philip Stieg
    Current Treatment Options in Neurology, 2016, 18
  • [23] Resolution of cranial neuropathies following treatment of intracranial aneurysms with the Pipeline Embolization Device
    Moon, Karam
    Albuquerque, Felipe C.
    Ducruet, Andrew F.
    Crowley, R. Webster
    Mcdougall, Cameron G.
    JOURNAL OF NEUROSURGERY, 2014, 121 (05) : 1085 - 1092
  • [24] Treatment of intracranial aneurysms with pipeline embolization device: a single-center experience
    Liang, Wenbao
    Yin, Jiaqi
    Lu, Chenyu
    Yang, Jianbo
    Ma, Xiaoqiang
    Zhang, Xin
    Turhon, Mirzat
    Yang, Xinling
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (04) : 2916 - 2926
  • [25] Treatment of Intracranial Aneurysms With Pipeline Embolization Device: Newer Applications and Technical Advances
    Murthy, Santosh B.
    Shah, Jharna
    Mangat, Halinder S.
    Stieg, Philip
    CURRENT TREATMENT OPTIONS IN NEUROLOGY, 2016, 18 (04) : 1 - 12
  • [26] Estimating the proportion of intracranial aneurysms likely to be amenable to treatment with the pipeline embolization device
    Brinjikji, Waleed
    Cloft, Harry J.
    Fiorella, David
    Lanzino, Giuseppe
    Kallmes, David F.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 (01) : 45 - 48
  • [27] Early Postmarket Results After Treatment of Intracranial Aneurysms With the Pipeline Embolization Device: A US Multicenter Experience
    Kan, Peter
    Siddiqui, AdnanH.
    Veznedaroglu, Erol
    Liebman, Kenneth M.
    Binning, Mandy J.
    Dumont, Travis M.
    Ogilvy, Christopher S.
    Gaughen, John R., Jr.
    Mocco, J.
    Velat, Gregory J.
    Ringer, Andrew J.
    Welch, Babu G.
    Horowitz, Michael B.
    Snyder, Kenneth V.
    Hopkins, L. Nelson
    Levy, Elad I.
    NEUROSURGERY, 2012, 71 (06) : 1080 - 1087
  • [28] Pipeline embolization device placement with local anesthesia for intracranial aneurysms?
    Sun, Liang
    Feng, Yi
    JOURNAL OF NEUROSURGERY, 2025, 142 (03)
  • [29] A systematic review of pipeline embolization device for giant intracranial aneurysms
    Lv, Xianli
    Ge, Huijian
    He, Hongwei
    Jiang, Chuhan
    Li, Youxiang
    NEUROLOGY INDIA, 2017, 65 (01) : 35 - 38
  • [30] Intracranial Aneurysms: Midterm Outcome of Pipeline Embolization Device-A Prospective Study in 143 Patients with 178 Aneurysms
    Yu, Simon Chun-Ho
    Kwok, Ching-Kwong
    Cheng, Pui-Wai
    Chan, Kwong-Yau
    Lau, Samuel Shun
    Lui, Wai-Man
    Leung, Ka-Ming
    Lee, Raymand
    Cheng, Harold Kin-Ming
    Cheung, Yuk-Ling
    Chan, Chi-Ming
    Wong, George Kwok-Chu
    Hui, Joyce Wai-Yi
    Wong, Yiu-Chung
    Tan, Chong-Boon
    Poon, Wai-Lun
    Pang, Kai-Yuen
    Wong, Alain Kai-Sing
    Fung, Kai-Hung
    RADIOLOGY, 2012, 265 (03) : 893 - 901