The influence of water vapour on the determination of glutaraldehyde vapour concentrations using an electrochemical fuel cell sensor

被引:2
|
作者
Holliman, PJ [1 ]
Kalaji, M
Wheldon-Williams, R
Evans, DL
Jones, TP
机构
[1] Univ Wales, Dept Chem, Bangor LL57 2UW, Gwynedd, Wales
[2] PPM Ltd, Bangor LL57 4BL, Gwynedd, Wales
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2003年 / 5卷 / 01期
关键词
D O I
10.1039/b209039m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effects of relative humidity (40-90% RH) and varying glutaraldehyde vapour concentrations (< 0.1 ppm) on the response of an electrochemical fuel cell sensor have been investigated over time (0 400 s). These studies have identified changes in the response of the fuel Cell with time after sampling, In particular, it has been Found that the maximum Cell Output for water vapour Occurs ca. 10 s after sampling whilst the response to glutaraldehyde occurs much later ( > 100 s). For mixtures, containing different ratios of water and glutaraldehyde vapours, the time taken to reach maximum fuel cell response varies between 10 and 100 s, depending on the ratio or the two vapours. For instance, glutaraldehyde vapour containing higher ",, RH has been found to result in shorter times to reach maximum fuel cell response. A comparison was made between measuring glutaraldehyde vapour concentrations in the presence of water vapour at the maximum fuel Cell response and also at a fixed interval (240 s) after sampling. Such a comparison resulted in reduction in the standard error from 36%, to 5%, for a glutaraldehyde vapour sample (0,023 ppm) measured at different values of relative humidity (40 to 80'%). Examination of the effect of the sample volume (30-60 ml) on the response of the fuel cell shows, as expected, an approximate doubling of the fuel cell response. Optimisation of the fuel Cell measurement parameters to measure a 60 nil sample leads to a lowering of the limit of detection from 0,083 ppm (for data taken at the maximum cell response) to 0.017 ppm for data measured 240, after sampling. In the light of recent reductions in the legal limits for exposure to glutaraldehyde. this has important implications for the measurement of glutaraldehyde vapour in the workplace.
引用
收藏
页码:106 / 110
页数:5
相关论文
共 50 条
  • [41] The water vapour sorption properties of Sitka spruce determined using a dynamic vapour sorption apparatus
    Hill, Callum A. S.
    Norton, Andrew J.
    Newman, Gary
    [J]. WOOD SCIENCE AND TECHNOLOGY, 2010, 44 (03) : 497 - 514
  • [42] The water vapour sorption properties of Sitka spruce determined using a dynamic vapour sorption apparatus
    Callum A. S. Hill
    Andrew J. Norton
    Gary Newman
    [J]. Wood Science and Technology, 2010, 44 : 497 - 514
  • [43] INFLUENCE OF OCEAN SURFACE RADIATION VARIATIONS ON ACCURACY OF DETERMINATION OF TOTAL WATER VAPOUR CONTENT IN ATMOSPHERE
    DEMIN, VV
    [J]. IZVESTIYA AKADEMII NAUK SSSR FIZIKA ATMOSFERY I OKEANA, 1971, 7 (07): : 811 - &
  • [44] Determination of water vapour column using IRS-P3 MOS data
    Singh, RP
    Roy, S
    [J]. CURRENT SCIENCE, 1999, 77 (08): : 1015 - 1019
  • [45] AN ATTEMPT OF DIRECT MEASUREMENTS OF WATER VAPOUR AND ATOMIC OXYGEN CONCENTRATIONS IN MESOSPHERE
    FEDYNSKII, AV
    PEROV, SP
    CHIZHOV, AF
    [J]. IZVESTIYA AKADEMII NAUK SSSR FIZIKA ATMOSFERY I OKEANA, 1967, 3 (05): : 557 - +
  • [46] Multicommutation cold vapour atomic fluorescence determination of Hg in water
    Reis, BF
    Ródenas-Torralba, E
    Sancenón-Buleo, J
    Morales-Rubio, A
    de la Guardia, M
    [J]. TALANTA, 2003, 60 (04) : 809 - 819
  • [47] Influence of various waterproofing agents on water and water vapour absorption and permeability
    Bajza, Z
    Hitrec, P
    Muzic, M
    [J]. JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2003, 87 (04): : 144 - 148
  • [48] TECHNIQUES FOR DETERMINATION OF AMMONIA AND WATER VAPOUR PRESSURES IN FERTILIZER SYSTEMS
    BENNETT, D
    BRADLEY, JK
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1971, (NSEP): : 30 - &
  • [49] Sensor system for long-term analysis of fuel vapour restraint systems
    Schieferstein, Eva
    Meller, Karl
    Graen-Heedfeld, Juergen
    Goebel, Ulrich
    Schmitz, Ingo
    Keller, Jurgen
    Seeger, Thomas
    [J]. TM-TECHNISCHES MESSEN, 2020, 87 (05) : 304 - 311
  • [50] Determination of saturated coefficient of tritiated water vapour generator system
    South-West Radioactive Metrology Department of Nuclear Industry, Chengdu 610005, China
    [J]. Yuanzineng Kexue Jishu, 2008, 3 (262-265):