An accurate method of radiological assessment of acetabular abduction and anteversion angles in three-dimensional reconstruction of multi-slice spiral computed tomography

被引:0
|
作者
Fan, Xin-Cheng [1 ]
Fan, Wen-Wen [2 ]
Wang, Feng-Yao [3 ]
Yu, Chun-Li [1 ]
Zhu, Hai-Tao [1 ]
Wei, Kai-Bin [1 ]
Ma, Zhen-Bo [4 ]
Liu, Feng [1 ]
机构
[1] Taian Ctr Hosp Shandong Prov, Dept Orthoped, Tai An, Shandong, Peoples R China
[2] Women & Children Hosp Qingdao City, Dept Pediat, Qingdao, Peoples R China
[3] Third Peoples Hosp Qingdao City, Dept Urinary Surg, Qingdao, Peoples R China
[4] Taian Ctr Hosp Shandong Prov, Dept Radiol, Tai An, Shandong, Peoples R China
关键词
Bone anteversion; Tomography; spiral computed; Arthroplasty; TOTAL HIP-ARTHROPLASTY; CT; REPLACEMENT; RADIOGRAPHS; ORIENTATION; OSTEOLYSIS; PLACEMENT; COMPONENT; DESIGN; MOTION;
D O I
10.23736/S1120-4826.16.02147-9
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
BACKGROUND: The characteristics of acetabular abduction angle and anteversion in three dimensions are still unclear. This study aimed to assess the diagnostic values of acetabular abduction angle and anteversion by three-dimensional reconstruction of multi-slice spiral CT (MSCT). METHODS: To verify the reliability and accuracy of the acetabular abduction angle and anteversion by using MSCT, both manual and radiological examinations of pelves (N = 30) and acetabula (N = 60) were included in the study. The manual examination was performed with a protractor and a digital goniometer (Protractor). The radiological examination was performed by using the digital X-ray photography (DR) and MSCT (3D). The pelvic anterior plane (PAP) served as a reference plane throughout the study. RESULTS: No significant difference was found among protractor, DR, and 3D measurement of acetabular abduction angles and anteversion angles [(16.24 +/- 4.74)degrees, (16.44 +/- 4.82)degrees vs. (15.82 +/- 4.62)degrees, P>0.05)]. Comparisons revealed significant positive correlations among protractor, DR, and 3D measurement of acetabular abduction angles and anteversion angles. CONCLUSIONS: Our study shows a new, reliable diagnostic tool for measuring the acetabular abduction angle and anteversion in THA or other hip surgeries.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 50 条
  • [31] Three-dimensional reconstruction of biliary tract using spiral computed tomography for laparoscopic cholecystectomy
    Ichii, H
    Takada, M
    Kashiwagi, R
    Sakane, M
    Tabata, F
    Ku, Y
    Fujimori, T
    Kuroda, Y
    WORLD JOURNAL OF SURGERY, 2002, 26 (05) : 608 - 611
  • [32] Simultaneous assessment of coronary artery stenosis and myocardial ischemia in adenosine triphosphate stress multi-slice spiral computed tomography
    Kurata, A
    Koyama, Y
    Kido, T
    Higashino, H
    Miyagawa, M
    Mochizuki, T
    Abe, M
    Shimin, M
    Watanabe, K
    Ohshita, A
    Yoshii, T
    Ogimoto, A
    Ohtsuka, T
    Okayama, H
    Higaki, J
    CIRCULATION, 2005, 112 (17) : U526 - U526
  • [33] The impact of different cone beam computed tomography and multi-slice computed tomography scan parameters on virtual three-dimensional model accuracy using a highly precise ex vivo evaluation method
    Matta, Ragai-Edward
    von Wilmowsky, Cornelius
    Neuhuber, Winfried
    Lell, Michael
    Neukam, Friedrich W.
    Adler, Werner
    Wichmann, Manfred
    Bergauer, Bastian
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (05) : 632 - 636
  • [34] Computed tomography arthrography with traction in the human hip for three-dimensional reconstruction of cartilage and the acetabular labrum
    Henak, C. R.
    Abraham, C. L.
    Peters, C. L.
    Sanders, R. K.
    Weiss, J. A.
    Anderson, A. E.
    CLINICAL RADIOLOGY, 2014, 69 (10) : E381 - E391
  • [35] Three-Dimensional Segmentation of Ventricular Heart Chambers from Multi-Slice Computerized Tomography: An Hybrid Approach
    Bravo, Antonio
    Vera, Miguel
    Garreau, Mireille
    Medina, Ruben
    DIGITAL INFORMATION AND COMMUNICATION TECHNOLOGY AND ITS APPLICATIONS, PT I, 2011, 166 : 287 - +
  • [36] The use of three-dimensional computed tomography reconstruction in the assessment of penetrating ballistic trauma
    Ramasamy, A.
    Hinsley, D. E.
    Brooks, A. J.
    EMERGENCY MEDICINE JOURNAL, 2009, 26 (03) : 228 - 228
  • [37] Spiral computed tomography with two- and three-dimensional reconstruction in the management of tibial plateau fractures
    Liow, RYL
    Birdsall, PD
    Mucci, B
    Greiss, ME
    ORTHOPEDICS, 1999, 22 (10) : 929 - 932
  • [38] Sacral distribution of prostatic lymph nodes visualized on spiral computed tomography with three-dimensional reconstruction
    Brössner, C
    Ringhofer, H
    Schatzl, G
    Madersbacher, S
    Powischer, G
    Kuber, W
    BJU INTERNATIONAL, 2002, 89 (01) : 44 - 47
  • [39] Accurate Assessment of Breast Volume by Computed Tomography Using Three-dimensional Imaging Device
    Fujii, Takaaki
    Yamaguchi, Satoru
    Yajima, Reina
    Tsutsumi, Soichi
    Asao, Takayuki
    Kuwano, Hiroyuki
    AMERICAN SURGEON, 2012, 78 (09) : 933 - 935
  • [40] Three-dimensional reconstruction by spiral computed tomography to locate aortic tear following blunt abdominal trauma
    Qureshi, A
    Roberts, N
    Nicholson, A
    Johnson, B
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 14 (04) : 316 - 317