High Performance Non-Enzymatic Electrochemical Lactate Sensor Based on ZnAl Layered Double Hydroxide Nanosheets Supported Gold Nanoparticles

被引:11
|
作者
Djebbi, Mohamed Amine [1 ,2 ]
Boubakri, Saber [3 ]
Braiek, Mohamed [4 ]
Jaffrezic-Renault, Nicole [4 ]
Namour, Philippe [2 ]
Amara, Abdesslem Ben Haj [1 ]
机构
[1] Univ Carthage, Fac Sci Bizerte, Lab Ressources Mat & Ecosyst RME, Zarzouna 7021, Tunisia
[2] Ctr Lyon Villeurbanne, UR RiverLy, INRAE, CS 20244, F-69625 Villeurbanne, France
[3] BiotechPole Sidi Thabet, Natl Inst Res & Phys Chem Anal, Ariana 2020, Tunisia
[4] Univ Lyon, Inst Analyt Sci, F-69100 Villeurbanne, France
关键词
Lactate; Layered Double Hydroxide (LDH); Gold Nanoparticles (AuNPs); Boron Doped Diamond; Electrochemical sensor; L-LACTIC ACID; ZNO NANORODS; AMPEROMETRIC BIOSENSOR; CARBON NANOTUBE; 4-NITROPHENOL; DEHYDROGENASE; ADSORPTION; ELECTRODES; SYSTEM; TISSUE;
D O I
10.1149/1945-7111/ac0226
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Lactate monitoring in body being of utmost importance in clinical diagnostics. It is a vital biomarker in the anaerobic metabolic pathway of humans, its elevation may lead to respiratory or hepatic failure and many more diseases and physiological fatigue. In this research, we propose a low-cost and high performance non-enzymatic electrochemical sensor aimed at the detection of lactate. The sensor was fabricated by assembling ZnAl layered double hydroxide (LDH) nanosheets along with gold nanoparticles (AuNPs) onto boron doped diamond electrodes (BDD). The as-prepared materials were characterized by X-ray diffractometry (XRD), Fourier transform infrared spectroscopy (FT-IR), UV-visible spectrophotometry (UV-vis), transmission (TEM) and scanning (SEM) electron microscopy, while the modified electrode was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The electrochemical measurements for lactate binding were performed using square wave voltammetry (SWV), revealed high sensitivity of 13.9 mu A/mu M/cm(2), broad detection range of 0.1-30 mu M and low detection limit up to 0.1 mu M. Besides, the proposed lactate sensor possessed excellent long-term stability, good reproducibility, repeatability and selectivity. The response currents of detection in biological samples were also close to the standard solutions. Therefore the developed sensor is promising to be used in clinical practice.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Carbon fibre-supported hierarchical NiCo layered double hydroxide nanosheets as non-enzymatic glucose sensors for sport drinks and serum
    Lo, Chieh-Tsung
    Wu, Yi-Shan
    Huang, Sheng-Min
    Tsai, Pei-Jung
    Lee, Chien-Liang
    [J]. FOOD CHEMISTRY, 2022, 383
  • [2] Protein adsorption on gold nanoparticles supported by a layered double hydroxide
    Jin, Lan
    He, Dandan
    Li, Zhongxuan
    Wei, Min
    [J]. MATERIALS LETTERS, 2012, 77 : 67 - 70
  • [3] A novel non-enzymatic glucose electrochemical sensor based on CNF@Ni-Co layered double hydroxide modified glassy carbon electrode
    Fu, Rong
    Lu, Youlan
    Ding, Yaping
    Li, Li
    Ren, Zhongming
    Si, Xiaojing
    Wu, Qingsheng
    [J]. MICROCHEMICAL JOURNAL, 2019, 150
  • [4] NiCo layered double hydroxide nanosheets with enhanced electrochemical performance
    Wang, Mengdi
    Liu, Xingyu
    Liu, Hengqi
    Zhao, Depeng
    Wu, Xiang
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2022, 903
  • [5] Synthesis of Carbon dots/Layered Double Hydroxide Composites for Non-enzymatic Electrochemical Sensing of Hydrogen Peroxide
    Prabhakaran, Praveena
    Ashok, M.
    [J]. DAE SOLID STATE PHYSICS SYMPOSIUM 2018, 2019, 2115
  • [6] Non-enzymatic glucose sensor with high sensitivity based on Cu-Al layered double hydroxides
    Wang, Fenfen
    Zhang, Yanwu
    Liang, Wenxia
    Chen, Langxing
    Li, Yijun
    He, Xiwen
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 : 41 - 47
  • [7] Nickel nanoparticles supported on porous silicon flour, application as a non-enzymatic electrochemical glucose sensor
    Ensafi, Ali A.
    Ahmadi, Najmeh
    Rezaei, Behzad
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 : 807 - 815
  • [8] Review-Enzymatic and Non-Enzymatic Electrochemical Sensor for Lactate Detection in Human Biofluids
    Md Shakhih, Muhammad Faiz
    Rosslan, Anis Suzziani
    Noor, Anas Mohd
    Ramanathan, Santheraleka
    Lazim, Azwan Mat
    Wahab, Asnida Abdul
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (06)
  • [9] Layered double hydroxide supported gold nanoparticles towards lignin depolymerization
    Song, Yang
    Crocker, Mark
    Wilson, Karen
    Isaacs, Mark
    Lee, Adam
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [10] A non-enzymatic hydrogen peroxide sensor based on vertical NiO nanosheets supported on the graphite sheet
    Liu, Wei
    Zhang, Hongxiu
    Yang, Bin
    Li, Zhongjian
    Lei, Lecheng
    Zhang, Xingwang
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 749 : 62 - 67