Fluorescent ion-selective nanosensors for intracellular analysis with improved lifetime and size

被引:61
|
作者
Dubach, J. Matthew [1 ]
Harjes, Daniel I. [1 ]
Clark, Heather A. [1 ]
机构
[1] Charles Stark Draper Lab Inc, Bioengn Grp, Cambridge, MA 02139 USA
关键词
D O I
10.1021/nl0707860
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We describe the synthesis and characterization of sodium-selective polymeric nanosensors that improves upon the lifetime and size of previous fiberless nanosensors. Sonication is used to form the polymer nanospheres that contain all the components needed for ion sensing. Even though the size is small (approximately 120 nm), the lifetime of these sensors in solution is on the order of a week. The surface coating has also been optimized for stability, biocompatibility, and ease of chemical modification.
引用
收藏
页码:1827 / 1831
页数:5
相关论文
共 50 条
  • [1] Lithium ion-selective electrode with improved lifetime
    Sim, JH
    Lee, KM
    Lee, JS
    Cho, DH
    Nam, H
    Cha, GS
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2001, 22 (07) : 765 - 768
  • [2] Potassium ion-selective fluorescent and pH independent nanosensors based on functionalized polyether macrocycles
    Jarolimova, Zdenka
    Vishe, Mahesh
    Lacour, Jerome
    Bakker, Eric
    CHEMICAL SCIENCE, 2016, 7 (01) : 525 - 533
  • [3] Subcellular carrier-based optical ion-selective nanosensors
    Carregal-Romero, Susana
    Montenegro, Jose-Maria
    Parak, Wolfgang J.
    Riveragil, Pilar
    FRONTIERS IN PHARMACOLOGY, 2012, 3
  • [4] ANALYSIS AND PRESENTATION OF INTRACELLULAR MEASUREMENTS OBTAINED WITH ION-SELECTIVE MICROELECTRODES
    FRY, CH
    HALL, SK
    BLATTER, LA
    MCGUIGAN, JAS
    EXPERIMENTAL PHYSIOLOGY, 1990, 75 (02) : 187 - 198
  • [5] MEASUREMENT OF INTRACELLULAR ION ACTIVITIES WITH ION-SELECTIVE MICROELECTRODES
    FUJIMOTO, M
    CELL STRUCTURE AND FUNCTION, 1983, 8 (04) : 401 - 401
  • [6] Ion-selective microelectrodes for measurement of intracellular ion concentrations
    Miller, AJ
    METHODS IN CELL BIOLOGY, VOL 49, 1995, 49 : 275 - 291
  • [7] ION-SELECTIVE ELECTRODE FOR INTRACELLULAR POTASSIUM MEASUREMENTS
    HAEMMERLI, A
    JANATA, J
    BROWN, HM
    ANALYTICAL CHEMISTRY, 1980, 52 (08) : 1179 - 1182
  • [8] IMPROVED ION-SELECTIVE ELECTRODE FOR PERCHLORATE
    WILSON, AC
    POOL, KH
    TALANTA, 1976, 23 (05) : 387 - 388
  • [9] Lifetime of ion-selective electrodes based on charged ionophores
    Bühlmann, P
    Umezawa, Y
    Rondinini, S
    Vertova, A
    Pigliucci, A
    Bertesago, L
    ANALYTICAL CHEMISTRY, 2000, 72 (08) : 1843 - 1852
  • [10] Ion-selective microelectrode array for intracellular detection on chip
    Guenat, OT
    Wang, XJ
    Dufour, JF
    van der Wal, P
    Morf, WE
    de Rooij, NF
    Koudelka-Hep, M
    BOSTON TRANSDUCERS'03: DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2003, : 1063 - 1066