Moisture conditions of outdoor air-ventilated crawl spaces in apartment buildings in a cold climate

被引:13
|
作者
Kurnitski, J [1 ]
Matilainen, M [1 ]
机构
[1] Aalto Univ, HVAC Lab, FIN-02015 Helsinki, Finland
关键词
crawl space; dynamic simulation; moisture evaporation; optimum air change; ground covers;
D O I
10.1016/S0378-7788(00)00061-X
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effects of air change and ground covers on crawl space moisture balance in a cold climate are discussed in this paper. The objectives were to assess the suitability of outdoor air-ventilation in the crawl spaces of apartment buildings, to determine the optimum air change rate with and without ground covers, and the effect of the ground covers' thermal insulation on moisture behaviour. Measured data from the test building was used to develop the crawl space model in a modular simulation environment, where the parametric simulations were carried out. The air change rate was varied between 0-10 ach to study moisture behaviour with covered and uncovered ground surface. Moisture evaporation was included in the moisture balance, but moisture storage in the constructions and in the ground was not. The results show that evaporation and thermal behaviour are the key elements determining the resulting relative humidity in crawl spaces. If moisture evaporation is entirely prevented, the crawl space may be left unventilated. In other cases, ventilation is always required to remove the moisture. The higher air change rates increased moisture evaporation from uncovered ground, but still brought about lower relative humidity. The rise from 0.5 to 3 ach increased evaporation from 2.4 to 4.9 g/m(2) h and decreased the highest monthly average of relative humidity from 81 to 74%. For the uncovered ground the lowest relative humidity was achieved at 2-3 ach air change in winter, but in the summer, the higher the air change the lower the relative humidity. Ground covers made it possible to decrease relative humidity and to increase temperature significantly due to reduced moisture evaporation. Ground cover with thermal insulation was in principle more effective than without insulation as it provided a slightly higher temperature rise in summer. The studied 5 cm expanded polystyrene layer reduced moisture evaporation to 0.3-0.4 g/m(2) h, increased crawl space temperature by 2-3 degrees C and decreased relative humidity below the 60% level when air change was 0.5-1 ach. In general, outdoor air-ventilation demonstrated very high performance in the crawl space of the studied apartment building when a ground cover was applied. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:15 / 29
页数:15
相关论文
共 50 条
  • [1] Moisture conditions in highly insulated outdoor ventilated crawl spaces in cold climates
    Matilainen, M
    Kurnitski, J
    [J]. ENERGY AND BUILDINGS, 2003, 35 (02) : 175 - 187
  • [2] Moisture conditions and energy consumption in heated crawl spaces in cold climates
    Matilainen, M
    Kurnitski, J
    Seppänen, O
    [J]. ENERGY AND BUILDINGS, 2003, 35 (02) : 203 - 216
  • [3] FACTORS INFLUENCING THE MOISTURE CONDITIONS IN CRAWL SPACES
    QUARLES, SL
    [J]. FOREST PRODUCTS JOURNAL, 1989, 39 (10) : 71 - 75
  • [4] Indoor climate conditions and hygrothermal loads in historic wooden apartment buildings in cold climates
    Arumaegi, Endrik
    Kalamees, Targo
    Kallavus, Urve
    [J]. PROCEEDINGS OF THE ESTONIAN ACADEMY OF SCIENCES, 2015, 64 (02) : 146 - 156
  • [5] Comparison of ventilated air channels for historical buildings with moisture problems
    Tazky, L.
    Sedlakova, A.
    [J]. ADVANCES AND TRENDS IN ENGINEERING SCIENCES AND TECHNOLOGIES, 2016, : 419 - 424
  • [6] Moisture Conditions in Exterior Walls for Net Zero Energy Buildings in Cold Climate Considering Future Climate Scenario
    Berggren, Bjorn
    Wall, Maria
    [J]. SEVENTH INTERNATIONAL COLD CLIMATE HVAC CONFERENCE, 2012, : 17 - 25
  • [7] Moisture control in buildings - How can varying outdoor climate be allowed for?
    Harderup, E
    Sandberg, PI
    [J]. DURABILITY OF BUILDING MATERIALS AND COMPONENTS 8, VOLS 1-4, PROCEEDINGS, 1999, : 923 - 931
  • [8] Performance Prediction Method in the Early Design Stage for Outdoor Ventilated Crawl Spaces Based on Artificial Neural Networks
    Yveras, Veronica
    [J]. JOURNAL OF BUILDING PHYSICS, 2010, 34 (01) : 43 - 56
  • [9] Simulating the effects of solar powered ventilation systems on energy and moisture conditions in crawl spaces
    Hoegh, Britt Haker
    [J]. 11TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB2017), 2017, 132 : 658 - 663
  • [10] Airborne Bacteria in Outdoor Air and Air of Mechanically Ventilated Buildings at City Scale in Hong Kong across Seasons
    Zhou, You
    Lai, Yonghang
    Tong, Xinzhao
    Leung, Marcus H. Y.
    Tong, Jimmy C. K.
    Ridley, Ian A.
    Lee, Patrick K. H.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (19) : 11732 - 11743