Method for dead time determination in reversed-phase capillary electrochromatography with methacrylate-based stationary phases

被引:4
|
作者
Ping, GC
Zhang, WB
Zhang, L
Zhang, LH
Shan, YC
Zhang, YK [1 ]
Schmitt-Kopplin, P
Kettrup, A
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatag Res & Anal Ctr, Dalian 116011, Peoples R China
[2] GSF Natl Ctr Environm & Hlth, Inst Ecol Chem, Neuherberg, Germany
[3] Tech Univ Munich, Inst Chem, Lehrstuhl Okol Chem & Umweltanalyt, Freising Weihenstephan, Germany
关键词
capillary electrochromatography; electroosmotic flow; polymer monolithic column; homologue series; dead time;
D O I
10.1365/s10337-003-0105-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for dead time determination in reversed-phase capillary electrochromatography (RP-CEC) with methacrylate-based monolithic stationary phases has been presented based on homologue series method. The dead times measured with homologue series method and thiourea, a commonly used electroosmotic flow (EOF) marker are compared under various conditions, such as the type and the concentration of organic modifier, ionic strength, and applied voltage. Results show that the former one is larger than the latter one. Under high ionic strength and low applied voltage, EOF velocity measured by thiourea is close to that determined by homologue series method.
引用
收藏
页码:803 / 806
页数:4
相关论文
共 50 条
  • [21] Monolithic columns with mixed modes of reversed-phase and anion-exchange stationary phase for capillary electrochromatography
    Fu, HJ
    Xie, CH
    Xiao, H
    Dong, J
    Hu, JW
    Zou, HF
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) : 237 - 244
  • [22] Solvation Processes on Reversed-Phase Stationary Phases
    Bocian, Szymon
    ADVANCES IN CHROMATOGRAPHY, VOL 56, 2019, 56 : 71 - 107
  • [23] Characterization of stationary phases for reversed-phase chromatography
    Molikova, Martina
    Jandera, Pavel
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (4-5) : 453 - 463
  • [24] A reversed-phase/hydrophilic bifunctional interaction mixed-mode monolithic column with biphenyl and quaternary ammonium stationary phases for capillary electrochromatography
    Mao, Zhenkun
    Hu, Changjun
    Li, Zhentao
    Chen, Zilin
    ANALYST, 2019, 144 (14) : 4386 - 4394
  • [25] Reversed-phase capillary electrochromatography of aloins and related constituents of aloe
    Girelli, AM
    Messina, A
    Ferrantelli, P
    Sinibaldi, M
    Tarola, AM
    CHROMATOGRAPHIA, 2001, 53 (Suppl 1) : S284 - S289
  • [26] Indirect resolution of β-blocker agents by reversed-phase capillary electrochromatography
    Aturki, Z
    Vichi, F
    Messina, A
    Sinibaldi, M
    ELECTROPHORESIS, 2004, 25 (4-5) : 607 - 614
  • [27] Reversed-phase capillary electrochromatography of aloins and related constituents of aloe
    A. M. Girelli
    A. Messina
    P. Ferrantelli
    M. Sinibaldi
    A. M. Tarola
    Chromatographia, 2001, 53 : S284 - S289
  • [28] Porous and non-porous stationary phases for capillary electrochromatography under conditions of reversed phase chromatography
    H. Engelhardt
    F. -T. Hafner
    Chromatographia, 2000, 52 : 769 - 776
  • [29] Porous and non-porous stationary phases for capillary electrochromatography under conditions of reversed phase chromatography
    Engelhardt, H
    Hafner, FT
    CHROMATOGRAPHIA, 2000, 52 (11-12) : 769 - 776
  • [30] Reversed-phase capillary electrochromatography for the simultaneous determination of acetylsalicylic acid, paracetamol, and caffeine in analgesic tablets
    Pucci, V
    Mandrioli, R
    Raggi, MA
    Fanali, S
    ELECTROPHORESIS, 2004, 25 (4-5) : 615 - 621