Sensitive determination of four β2-agonists in pig feed by capillary electrophoresis using on-line sample preconcentration with contactless conductivity detection

被引:15
|
作者
Gao, Fan [1 ]
Wu, Minglei [1 ]
Zhang, Yi [1 ]
Wang, Guan [1 ]
Wang, Qingjiang [1 ]
He, Pingang [1 ]
Fang, Yuzhi [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200241, Peoples R China
关键词
Field-enhanced sample injection (FESI); beta(2)-Agonists; Capillary electrophoresis; Contactless conductivity detection; PERFORMANCE LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; AMPEROMETRIC DETECTION; BETA-AGONISTS; CLENBUTEROL; URINE; SALBUTAMOL; EXTRACTION; DRUGS;
D O I
10.1016/j.jchromb.2014.10.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, an on-line preconcentration method of field-enhanced sample injection (FESI) was implemented in the determination of four beta(2)-agoinsts terbutaline (TER), procaterol (PRO), formoterol (FOR) and bambuterol (BAM) by capillary electrophoresis coupled with capacitively coupled contactless conductivity detection (CE-(CD)-D-4). Under optimized conditions the background electrolyte (BGE) was 5 mM Tris(hydroxymethyl)aminomethane (Tris) and 10 mM citric acid (Cit) at a pH of 3.2 while the sample dilution solution was obtained by methanol. The detection limits (defined as S/N = 3) of this method were 0.02 mg/L for TER, PRO, FOR, BAM, which were much lower than that of the conventional CE-(CD)-D-4 method without preconcentration procedure, the enhancement factors were greatly improved to be 30-40-fold. The linearity ranges of four beta(2)-agoinsts were 0.1-15 mg/L, with good linear correlation coefficients (r(2) > 0.9900). In order to evaluate the application potential of the developed method, real sample from pig feed was analyzed with recoveries of 91.4-106.2%. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:29 / 32
页数:4
相关论文
共 50 条
  • [31] The use of polarity switching for the sensitive determination of nitrate in human cerebrospinal fluid by capillary electrophoresis with contactless conductivity detection
    Tuma, Petr
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1447 : 148 - 154
  • [32] Highly sensitive rapid determination of orotic acid in urine samples using a field-amplified sample stacking approach in capillary electrophoresis coupled with contactless conductivity detection
    Adimcilar, Veselina
    Saygili, Merve Taser
    Cansever, Mehmet Serif
    Oztekin, Nevin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 238
  • [33] Determination of pharmaceuticals classified as emerging pollutants using capillary electrophoresis with capacitively coupled contactless conductivity detection
    Quek, Ngee Mien
    Law, Wai Siang
    Lau, Hiu Fung
    Zhao, Jian Hong
    Hauser, Peter C.
    Li, Sam Fong Yau
    ELECTROPHORESIS, 2008, 29 (17) : 3701 - 3709
  • [34] Trace determination of perchlorate using electromembrane extraction and capillary electrophoresis with capacitively coupled contactless conductivity detection
    Kiplagat, Isaac K.
    Thi Kieu Oanh Doan
    Kuban, Pavel
    Bocek, Petr
    ELECTROPHORESIS, 2011, 32 (21) : 3008 - 3015
  • [35] Determination of carbapenem antibiotics using a purpose-made capillary electrophoresis instrument with contactless conductivity detection
    Thi Ngoc Mai Pham
    Thai Binh Le
    Le, Duc Dung
    Tran Hung Ha
    Ngoc Son Nguyen
    Tien Duc Pham
    Hauser, Peter C.
    Thi Anh Huong Nguyen
    Thanh Duc Mai
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 178
  • [36] Fast determination of ethambutol in pharmaceutical formulations using capillary electrophoresis with capacitively coupled contactless conductivity detection
    Fracassi da Silva, Jose Alberto
    de Castro, Nathan Vitorazzi
    de Jesus, Dosil Pereira
    Faria, Adriana F.
    De Souza, Marcus V. N.
    Leal de Oliveira, Marcone Augusto
    ELECTROPHORESIS, 2010, 31 (03) : 570 - 574
  • [37] Determination of Heavy Metal Ions by Capillary Electrophoresis with Contactless Conductivity Detection after Field-amplified Sample Injection
    Feng Tan
    Bingcheng Yang
    Yafeng Guan
    Analytical Sciences, 2005, 21 : 955 - 958
  • [38] Determination of heavy metal ions by capillary electrophoresis with contactless conductivity detection after field-amplified sample injection
    Tan, F
    Yang, BC
    Guan, YF
    ANALYTICAL SCIENCES, 2005, 21 (08) : 955 - 958
  • [39] Determination of trace Zn2+ by capillary electrophoresis with field-amplified sample injection and high voltage contactless conductivity detection
    Tan, F
    Yang, BC
    Guan, YF
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2005, 26 (05): : 825 - 828
  • [40] Separation and determination of alkyl sulfate surfactants in wastewater by capillary electrophoresis coupled with contactless conductivity detection after preconcentration by simultaneous adsorption using alumina beads
    Pham, Huy Dong
    Dang, Thi Huyen My
    Nguyen, Thi Tuyet Nhung
    Nguyen, Thi Anh Huong
    Pham, Thi Ngoc Mai
    Pham, Tien Duc
    ELECTROPHORESIS, 2021, 42 (03) : 191 - 199