Sensitive determination of four β2-agonists in pig feed by capillary electrophoresis using on-line sample preconcentration with contactless conductivity detection

被引:15
|
作者
Gao, Fan [1 ]
Wu, Minglei [1 ]
Zhang, Yi [1 ]
Wang, Guan [1 ]
Wang, Qingjiang [1 ]
He, Pingang [1 ]
Fang, Yuzhi [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 200241, Peoples R China
关键词
Field-enhanced sample injection (FESI); beta(2)-Agonists; Capillary electrophoresis; Contactless conductivity detection; PERFORMANCE LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; AMPEROMETRIC DETECTION; BETA-AGONISTS; CLENBUTEROL; URINE; SALBUTAMOL; EXTRACTION; DRUGS;
D O I
10.1016/j.jchromb.2014.10.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, an on-line preconcentration method of field-enhanced sample injection (FESI) was implemented in the determination of four beta(2)-agoinsts terbutaline (TER), procaterol (PRO), formoterol (FOR) and bambuterol (BAM) by capillary electrophoresis coupled with capacitively coupled contactless conductivity detection (CE-(CD)-D-4). Under optimized conditions the background electrolyte (BGE) was 5 mM Tris(hydroxymethyl)aminomethane (Tris) and 10 mM citric acid (Cit) at a pH of 3.2 while the sample dilution solution was obtained by methanol. The detection limits (defined as S/N = 3) of this method were 0.02 mg/L for TER, PRO, FOR, BAM, which were much lower than that of the conventional CE-(CD)-D-4 method without preconcentration procedure, the enhancement factors were greatly improved to be 30-40-fold. The linearity ranges of four beta(2)-agoinsts were 0.1-15 mg/L, with good linear correlation coefficients (r(2) > 0.9900). In order to evaluate the application potential of the developed method, real sample from pig feed was analyzed with recoveries of 91.4-106.2%. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:29 / 32
页数:4
相关论文
共 50 条
  • [1] Sensitive simultaneous determination of three sulfanilamide artificial sweeters by capillary electrophoresis with on-line preconcentration and contactless conductivity detection
    Yang, Lirong
    Zhou, Shengli
    Xiao, Yuezhou
    Tang, Yufeng
    Xie, Tianyao
    FOOD CHEMISTRY, 2015, 188 : 446 - 451
  • [2] Separation and Determination of β2-Agonists in Swine Feed Using Field-Amplified On-Line Sample Stacking Method by Capillary Zone Electrophoresis
    Li, Chongyang
    Land, Donald P.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2009, 32 (15) : 2135 - 2145
  • [3] Sensitive arsenic speciation by capillary electrophoresis using UV absorbance detection with on-line sample preconcentration techniques
    Lee, Ho Gyun
    Kwon, Joon Yub
    Chung, Doo Soo
    TALANTA, 2018, 181 : 366 - 372
  • [4] Automated capillary electrophoresis with on-line preconcentration by solid phase extraction using a sequential injection manifold and contactless conductivity detection
    Thanh Duc Mai
    Bomastyk, Benjamin
    Hong Anh Duong
    Hung Viet Pham
    Hauser, Peter C.
    ANALYTICA CHIMICA ACTA, 2012, 727 : 1 - 7
  • [5] Efficient sample clean-up and online preconcentration for sensitive determination of melamine in milk samples by capillary electrophoresis with contactless conductivity detection
    Ji, Yan-ling
    Chen, Xiao-wei
    Zhang, Zhu-bao
    Li, Jing
    Xie, Tian-yao
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (20) : 3000 - 3006
  • [6] On-line sample preconcentration in capillary electrophoresis, focused on the determination of proteins and peptides
    Stroink, T
    Paarlberg, E
    Waterval, JCM
    Bult, A
    Underberg, WJM
    ELECTROPHORESIS, 2001, 22 (12) : 2375 - 2383
  • [7] Determination of β-agonists in pig feed, pig urine and pig liver using capillary electrophoresis with electrochemical detection
    Wang, Weiyu
    Zhang, Yulian
    Wang, Jinyan
    Shi, Xue
    Ye, Jiannong
    MEAT SCIENCE, 2010, 85 (02) : 302 - 305
  • [8] Online preconcentration in capillary electrophoresis with contactless conductivity detection for sensitive determination of sorbic and benzoic acids in soy sauce
    Wei, Ruixia
    Li, Wenhua
    Yang, Lirong
    Jiang, Yixiu
    Xie, Tianyao
    TALANTA, 2011, 83 (05) : 1487 - 1490
  • [9] Simple semi-automated portable capillary electrophoresis instrument with contactless conductivity detection for the determination of β-agonists in pharmaceutical and pig-feed samples
    Thi Anh Huong Nguyen
    Thi Ngoc Mai Pham
    Thi Tuoi Doan
    Thi Thao Ta
    Saiz, Jorge
    Thi Quynh Hoa Nguyen
    Hauser, Peter C.
    Thanh Duc Mai
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1360 : 305 - 311
  • [10] On-Line Flow Injection-Capillary Electrophoresis Instrument with Contactless Conductivity Detection for Sensitive Cation Analyses
    Sprung, Christoph
    Siren, Heli
    Rovio, Stella
    Tyopponen, Teemu
    SEPARATION SCIENCE AND TECHNOLOGY, 2008, 43 (15) : 3856 - 3872