Computerised pinch dynamometry in the assessment of adult hand spasticity

被引:1
|
作者
Barden, Hannah L. H. [1 ,2 ]
Baguley, Ian J. [1 ,3 ]
Nott, Melissa T. [1 ,4 ]
Heard, Robert [2 ]
Chapparo, Christine [2 ]
机构
[1] Westmead Hosp, Brain Injury Rehabil Serv, Wentworthville, NSW 2145, Australia
[2] Univ Sydney, Fac Hlth Sci, Sydney, NSW 2006, Australia
[3] Univ Sydney, Sydney Med Sch, Sydney, NSW 2006, Australia
[4] Charles Sturt Univ, Sch Community Hlth, Albury, NSW, Australia
关键词
rehabilitation; muscle spasticity; upper extremity; muscle strength dynamometer; pinch; adult; TOXIN-A INJECTIONS; NORMATIVE DATA; GRIP STRENGTH; RELIABILITY; PERFORMANCE; VALIDITY; STROKE; RATES;
D O I
10.1111/1440-1630.12141
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background/aimThe hand engages with the environment through the grasp, stabilisation, manipulation and release of objects during everyday tasks, activities and routines. Upper motor neuron syndrome following acquired brain injury may negatively impact hand function, reducing strength, range of motion and motor control. It is important for clinicians to reliably measure such impacts, particularly for the impact of intervention and to monitor change in performance over time. Therefore, the aim of this study was to investigate the test-retest reliability and construct validity of Dynamic Computerised pinch Dynamometry for measuring fine hand motor performance following acquired brain injury. MethodsThe Dynamic Computerised pinch Dynamometry protocol was completed by 36 community dwelling adults and 27 healthy adults using a simulated pinch and release task in lateral and pincer grip positions. Measurements were conducted over two testing occasions approximately five weeks apart. Dynamic Computerised pinch Dynamometry output was evaluated to determine the test-retest reliability and construct validity of the measure. ResultsTest-retest reliability scores using Kendall coefficient of concordance ranged from W=0.61-0.94. Dynamic Computerised pinch Dynamometry discriminated between participants with and without acquired brain injury (z=4.97-6.50, P<0.05) and between the affected and non-affected hand of participants with acquired brain injury (z=3.37-5.22, P<0.001). ConclusionsDynamic Computerised pinch Dynamometry in both lateral and pincer positions had fair to excellent test-retest reliability, and had good construct validity for discrimination between participants with and without acquired brain injury as well as between the affected and non-affected hand of participants with acquired brain injury.
引用
收藏
页码:415 / 423
页数:9
相关论文
共 50 条
  • [41] Comparison of Isometric Portable Fixed Dynamometry to Iisokinetic Dynamometry for Assessment of Hip Strength
    Kollock, Roger O., Jr.
    Van Lunen, Bonnie
    Linza, Jennifer L.
    Onate, James A.
    INTERNATIONAL JOURNAL OF ATHLETIC THERAPY & TRAINING, 2013, 18 (06): : 1 - 6
  • [42] Clinical Assessment of Hand Motor Performance After Acquired Brain Injury With Dynamic Computerized Hand Dynamometry: Construct, Concurrent, and Predictive Validity
    Barden, Hannah L.
    Nott, Melissa T.
    Heard, Robert
    Chapparo, Christine
    Baguley, Ian J.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (12): : 2257 - 2263
  • [43] Botulinum toxin treatment of adult spasticity - A benefit-risk assessment
    Sheean, G
    DRUG SAFETY, 2006, 29 (01) : 31 - 48
  • [44] Computerised formal assessment
    Pritchett, Norma
    Zakrzewski, Stan
    British Journal of Educational Technology, 1995, 26 (02)
  • [45] A Multi-Layered Quantitative Assessment Approach for Hand Spasticity Based on a Cable-Actuated Hand Exoskeleton
    Yu, Hao
    Nelson, Alyson
    Erden, Mustafa Suphi
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2025, 10 (03): : 2335 - 2342
  • [46] Peak power assessment in isokinetic dynamometry
    Iossifidou, AN
    Baltzopoulos, V
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2000, 82 (1-2) : 158 - 160
  • [47] Design and Characterization of a Novel Compact Hand Exoskeleton Robot for Telerehabilitation and Muscle Spasticity Assessment
    Lai, Jianwei
    Song, Aiguo
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2024, 29 (04) : 2416 - 2427
  • [48] Quantitative Assessment of Hand Spasticity After Stroke: Imaging Correlates and Impact on Motor Recovery
    Plantin, Jeanette
    Pennati, Gaia, V
    Roca, Pauline
    Baron, Jean-Claude
    Laurencikas, Evaldas
    Weber, Karin
    Godbolt, Alison K.
    Borg, Jorgen
    Lindberg, Pavel G.
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [49] Foot and Ankle Strength Assessment Using Hand-Held Dynamometry: Reliability and Age-Related Differences
    Spink, Martin J.
    Fotoohabadi, Mohammad R.
    Menz, Hylton B.
    GERONTOLOGY, 2010, 56 (06) : 525 - 532
  • [50] Hand-held dynamometry in patients with haematological malignancies: Measurement error in the clinical assessment of knee extension strength
    Knols, Ruud H.
    Aufdemkampe, Geert
    de Bruin, Eling D.
    Uebelhart, Daniel
    Aaronson, Neil K.
    BMC MUSCULOSKELETAL DISORDERS, 2009, 10