Ion trap for mass-selective production of nanoclusters

被引:23
|
作者
Kanayama, T
Murakami, H
机构
[1] Natl Inst Adv Interdisciplinary Res, Joint Res Ctr Atom Technol, Tsukuba, Ibaraki 305, Japan
[2] Angstrom Technol Partnership, JRCAT, Tsukuba, Ibaraki 305, Japan
来源
关键词
D O I
10.1116/1.589749
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To form nanoclusters with a specified atomic structure, an electrical trapping technique of charged particles was developed that allows us to confine, grow, and mass selectively eject cluster ions. Theoretical calculations and experiments using inert gas ions indicate that the developed ion trap can confine ions with a wide range of mass values using the external field of an ac quadrupole, and send out the ions mass selectively through the internal region of the quadrupole. To demonstrate performance, Si6H12+ clusters were selectively grown using SiH4 as a starting material. In the trap, confined SiHx+ ions were allowed to react with neutral SiH4 molecules or SiHy radicals, and SinHx+ clusters were grown, from which Si6H12+ clusters were automatically ejected by tuning trapping parameters. (C) 1997 American Vacuum Society.
引用
收藏
页码:2882 / 2886
页数:5
相关论文
共 50 条
  • [41] Diagnosis of a benzene discharge with a mass-selective spectroscopic technique
    Güthe, F
    Ding, HB
    Pino, T
    Maier, JP
    CHEMICAL PHYSICS, 2001, 269 (1-3) : 347 - 355
  • [42] THEORETICAL TREATMENT OF MASS-SELECTIVE ION STORAGE IN 3-DIMENSIONAL ROTATIONALLY SYMMETRIC QUADRUPOLE FIELDS
    DAWSON, PH
    WHETTEN, NR
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1967, 4 (05): : 325 - &
  • [43] SELECTIVE ION ISOLATION REJECTION OVER A BROAD MASS RANGE IN THE QUADRUPOLE ION TRAP
    MCLUCKEY, SA
    GOERINGER, DE
    GLISH, GL
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (01) : 11 - 21
  • [44] A study of octupolar excitation for mass-selective centering in Penning traps
    Rosenbusch, M.
    Boehm, Ch.
    Borgmann, Ch.
    Breitenfeldt, M.
    Herlert, A.
    Kowalska, M.
    Kreim, S.
    Marx, G.
    Naimi, S.
    Neidherr, D.
    Schneider, R.
    Schweikhard, L.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 314 : 6 - 12
  • [45] A MASS-SELECTIVE NEUTRAL PARTICLE ENERGY ANALYZER WITH BACKGROUND REJECTION
    VANBLOKLAND, AAE
    GRIMBERGEN, TWM
    VANDERVEN, HW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (03): : 1978 - 1987
  • [46] A mass-selective ion transfer line coupled with a uniform supersonic flow for studying ion-molecule reactions at low temperatures
    Joalland, B.
    Jamal-Eddine, N.
    Papanastasiou, D.
    Lekkas, A.
    Carles, S.
    Biennier, L.
    JOURNAL OF CHEMICAL PHYSICS, 2019, 150 (16):
  • [47] Miniaturized mass-selective detector with atmospheric pressure chemical ionization
    Makas, AL
    Troshkov, ML
    Kudryavtsev, AS
    Lunin, V
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 800 (1-2): : 63 - 67
  • [48] Mass-selective vibrational spectroscopy of vanadium oxide cluster ions
    Asmis, Knut R.
    Sauer, Joachim
    MASS SPECTROMETRY REVIEWS, 2007, 26 (04) : 542 - 562
  • [49] MASS-SELECTIVE TRAPPING OF PULSED CHARGED-PARTICLE BEAMS
    O, CS
    SCHUESSLER, HA
    APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1982, 27 (03): : 129 - 135
  • [50] Integration of continuous-flow accelerator mass spectrometry with chromatography and mass-selective detection
    Flarakos, Jimmy
    Liberman, Rosa G.
    Tannenbaum, Steven R.
    Skipper, Paul L.
    ANALYTICAL CHEMISTRY, 2008, 80 (13) : 5079 - 5085