Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation

被引:63
|
作者
Frerichs, I. [1 ]
Schmitz, G. [1 ]
Pulletz, S. [1 ]
Schaedler, D. [1 ]
Zick, G. [1 ]
Scholz, J. [1 ]
Weiler, N. [1 ]
机构
[1] Univ Med Ctr Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, D-24105 Kiel, Germany
关键词
EIT; electrical impedance tomography; lung impedance; regional lung ventilation; positive end-expiratory pressure;
D O I
10.1088/0967-3334/28/7/S19
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrical impedance tomography (EIT) has the potential to become a new tool for bedside monitoring of regional lung ventilation. The aim of our study was to assess the reproducibility of regional lung ventilation distribution determined by EIT during mechanical ventilation under identical ventilator settings. The experiments were performed on 10 anaesthetized supine pigs ventilated in a volume-controlled mode. EIT measurements were performed with the Goe-MF II device (Viasys Healthcare, Hochberg, Germany) during repeated changes in positive end-expiratory pressure (PEEP) from 0 to 10 cm H2O. Regional lung ventilation was determined in the right and left hemithorax as well as in 64 regions of interest evenly distributed over each chest side in the ventrodorsal direction. Ventilation distributions in both lungs were visualized as ventrodorsal ventilation profiles and shifts in ventilation distribution quantified in terms of centres of ventilation in relation to the chest diameter. The proportion of the right lung on total ventilation in the chest cross-section was 0.54 +/- 0.04 and remained unaffected by repetitive PEEP changes. Initial PEEP increase resulted in a redistribution of ventilation towards dorsal lung regions with a shift of the centre of ventilation from 45 +/- 3% to 49 +/- 3% of the chest diameter in the right and from 47 +/- 2% to 50 +/- 2% in the left hemithorax. Excellent reproducibility of the results in the individual regions of interest with almost identical patterns of ventilation distribution was found during repeated PEEP changes.
引用
收藏
页码:S261 / S267
页数:7
相关论文
共 50 条
  • [31] Influence of tidal volume on ventilation inhomogeneity assessed by electrical impedance tomography during controlled mechanical ventilation
    Becher, T.
    Kott, M.
    Schaedler, D.
    Vogt, B.
    Meinel, T.
    Weiler, N.
    Frerichs, I.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (06) : 1137 - 1146
  • [32] Assessment of Regional Ventilation During Recruitment Maneuver by Electrical Impedance Tomography in Dogs
    Ambrosio, Aline Magalhaes
    Sanchez, Ana Flavia
    Pereira, Marco Aurelio Amador
    De Andrade, Felipe Silveira Rego Monteiro
    Rodrigues, Renata Ramos
    Vitorasso, Renato de Lima
    Moriya, Henrique Takachi
    Fantoni, Denise Tabacchi
    [J]. FRONTIERS IN VETERINARY SCIENCE, 2022, 8
  • [33] Ventilation and cardiac/perfusion related impedance changes of the lung determined by Electrical Impedance Tomography in cystic fibrosis
    Krueger-Ziolek, S.
    Schullcke, B.
    Gong, B.
    Mueller-Lisse, U.
    Moeller, K.
    [J]. IFAC PAPERSONLINE, 2017, 50 (01): : 9938 - 9942
  • [34] Electrical Impedance Tomography for Confirmation of Lung Isolation during One-lung Ventilation
    Hempel, Gunther
    Schulze, Gero
    Wirtz, Hubert
    Wrigge, Hermann
    [J]. ANESTHESIOLOGY, 2018, 129 (03) : 580 - 580
  • [35] The time taken for the regional distribution of ventilation to stabilise: an investigation using electrical impedance tomography
    Caruana, L. R.
    Paratz, J. D.
    Chang, A.
    Barnett, A. G.
    Fraser, J. F.
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2015, 43 (01) : 88 - 91
  • [36] Regional Distribution of Ventilation Measured by Electrical Impedance Tomography (EIT) in Mechanically Ventilated Children
    Inany, H.
    Rettig, J.
    Smallwood, C.
    Walsh, B. K.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [37] Regional ventilation in cystic fibrosis measured by electrical impedance tomography
    Zhao, Zhanqi
    Fischer, Rainald
    Frerichs, Inez
    Mueller-Lisse, Ullrich
    Moeller, Knut
    [J]. JOURNAL OF CYSTIC FIBROSIS, 2012, 11 (05) : 412 - 418
  • [38] Regional ventilation of patients with hemidiaphragm paralysis by electrical impedance tomography
    Pereira, Mayra Caleffi
    Torsani, Vinicius
    Apanavicius, Andre
    Ferreira, Jeferson George
    Iamonti, Vinicius C.
    Passos Amato, Marcelo Britto
    Ribeiro de Carvalho, Carlos Roberto
    Pereira de Albuquerque, Andre Luis
    Caruso, Pedro
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [39] Spatial Ventilation Inhomogeneity Determined by Electrical Impedance Tomography in Patients With Chronic Obstructive Lung Disease
    Frerichs, Inez
    Lasarow, Livia
    Strodthoff, Claas
    Vogt, Barbara
    Zhao, Zhanqi
    Weiler, Norbert
    [J]. FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [40] Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study
    Richard, J. C.
    Pouzot, C.
    Gros, A.
    Tourevieille, C.
    Lebars, D.
    Lavenne, F.
    Frerichs, I.
    Guerin, C.