Body-Worn IMU-Based Human Hip and Knee Kinematics Estimation during Treadmill Walking

被引:21
|
作者
McGrath, Timothy [1 ,4 ,5 ]
Stirling, Leia [2 ,3 ]
机构
[1] MIT, Dept Aeronaut & Astronaut, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[2] Univ Michigan, Ind & Operat Engn, 1205 Beal Ave, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Robot Inst, 2505 Hayward St, Ann Arbor, MI 48109 USA
[4] MIT, Cambridge, MA 02139 USA
[5] JES Tech LLC, 16870 Royal Crest Dr, Houston, TX 77058 USA
基金
美国国家科学基金会;
关键词
IMU; human; joint angle; self-calibrating; biomechanics; knee; hip; soft tissue artifacts; treadmill; walking; gait; JOINT COORDINATE SYSTEM; AMBULATORY MEASUREMENT; MOTION; ACCELEROMETER;
D O I
10.3390/s22072544
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Traditionally, inertial measurement unit (IMU)-based human joint angle estimation techniques are evaluated for general human motion where human joints explore all of their degrees of freedom. Pure human walking, in contrast, limits the motion of human joints and may lead to unobservability conditions that confound magnetometer-free IMU-based methods. This work explores the unobservability conditions emergent during human walking and expands upon a previous IMU-based method for the human knee to also estimate human hip angles relative to an assumed vertical datum. The proposed method is evaluated (N = 12) in a human subject study and compared against an optical motion capture system. Accuracy of human knee flexion/extension angle (7.87 degrees absolute root mean square error (RMSE)), hip flexion/extension angle (3.70 degrees relative RMSE), and hip abduction/adduction angle (4.56 degrees relative RMSE) during walking are similar to current state-of-the-art self-calibrating IMU methods that use magnetometers. Larger errors of hip internal/external rotation angle (6.27 degrees relative RMSE) are driven by IMU heading drift characteristic of magnetometer-free approaches and non-hinge kinematics of the hip during gait, amongst other error sources. One of these sources of error, soft tissue perturbations during gait, is explored further in the context of knee angle estimation and it was observed that the IMU method may overestimate the angle during stance and underestimate the angle during swing. The presented method and results provide a novel combination of observability considerations, heuristic correction methods, and validation techniques to magnetic-blind, kinematic-only IMU-based skeletal pose estimation during human tasks with degenerate kinematics (e.g., straight line walking).
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Magnetometer-Free, IMU-Based Foot Progression Angle Estimation for Real-Life Walking Conditions
    Tan, Tian
    Strout, Zachary A.
    Xia, Haisheng
    Orban, Mostafa
    Shull, Peter B.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2021, 29 : 282 - 289
  • [32] Motion Forecasting Network (MoFCNet): IMU-Based Human Motion Forecasting for Hip Assistive Exoskeleton
    Zhang, Xingxuan
    Zhang, Haojian
    Hu, Jianhua
    Deng, Jieren
    Wang, Yunkuan
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2023, 8 (09) : 5783 - 5790
  • [33] IMU-Based Energy Expenditure Estimation for Various Walking Conditions Using a Hybrid CNN-LSTM Model
    Lee, Chang June
    Lee, Jung Keun
    SENSORS, 2024, 24 (02)
  • [34] A comparative study on electromyographic and kinematics parameters of the knee joint during walking an level treadmill and level ground
    Rahimi, A.
    Majidirad, F.
    Movahed, M.
    Vali, F.
    ESMAC: PROCEEDINGS OF THE 17TH ANNUAL MEETING OF THE EUROPEAN SOCIETY OF MOVEMENT ANALYSIS FOR ADULTS AND CHILDREN, 2008, : 17 - +
  • [35] Evaluation of Upper Body and Lower Limbs Kinematics through an IMU-Based Medical System: A Comparative Study with the Optoelectronic System
    Cerfoglio, Serena
    Capodaglio, Paolo
    Rossi, Paolo
    Conforti, Ilaria
    D'Angeli, Valentina
    Milani, Elia
    Galli, Manuela
    Cimolin, Veronica
    SENSORS, 2023, 23 (13)
  • [36] The effect of hip exoskeleton weight on kinematics, kinetics, and electromyography during human walking
    Normand, Michael A.
    Lee, Jeonghwan
    Su, Hao
    Sulzer, James S.
    JOURNAL OF BIOMECHANICS, 2023, 152
  • [37] Marker-Based Versus IMU-Based Kinematics for Estimates of Lumbar Spine Loads Using a Full-Body Musculoskeletal Model
    Prado, Maria
    Oyama, Sakiko
    Giambini, Hugo
    JOURNAL OF APPLIED BIOMECHANICS, 2024, 40 (04) : 306 - 315
  • [38] The role of menisci in knee contact mechanics and secondary kinematics during human walking
    Hu, Jiayu
    Xin, Hua
    Chen, Zhenxian
    Zhang, Qida
    Peng, Yinghu
    Jin, Zhongmin
    CLINICAL BIOMECHANICS, 2019, 61 : 58 - 63
  • [39] A Deep Learning Control Strategy of IMU-Based Joint Angle Estimation for Hip Power-Assisted Swimming Exoskeleton
    Chen, Longwen
    Yan, Xue
    Hu, Dean
    IEEE SENSORS JOURNAL, 2023, 23 (13) : 15058 - 15070
  • [40] Vision-based human joint angular velocity estimation during squat and walking on a treadmill actions
    Kumar, Konki Sravan
    Jamsarndorj, Ankhzaya
    Jung, Dawoon
    Lee, Daehyun
    Kim, Jinwook
    Mun, Kyung-Ryoul