Body-Worn IMU-Based Human Hip and Knee Kinematics Estimation during Treadmill Walking

被引:21
|
作者
McGrath, Timothy [1 ,4 ,5 ]
Stirling, Leia [2 ,3 ]
机构
[1] MIT, Dept Aeronaut & Astronaut, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[2] Univ Michigan, Ind & Operat Engn, 1205 Beal Ave, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Robot Inst, 2505 Hayward St, Ann Arbor, MI 48109 USA
[4] MIT, Cambridge, MA 02139 USA
[5] JES Tech LLC, 16870 Royal Crest Dr, Houston, TX 77058 USA
基金
美国国家科学基金会;
关键词
IMU; human; joint angle; self-calibrating; biomechanics; knee; hip; soft tissue artifacts; treadmill; walking; gait; JOINT COORDINATE SYSTEM; AMBULATORY MEASUREMENT; MOTION; ACCELEROMETER;
D O I
10.3390/s22072544
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Traditionally, inertial measurement unit (IMU)-based human joint angle estimation techniques are evaluated for general human motion where human joints explore all of their degrees of freedom. Pure human walking, in contrast, limits the motion of human joints and may lead to unobservability conditions that confound magnetometer-free IMU-based methods. This work explores the unobservability conditions emergent during human walking and expands upon a previous IMU-based method for the human knee to also estimate human hip angles relative to an assumed vertical datum. The proposed method is evaluated (N = 12) in a human subject study and compared against an optical motion capture system. Accuracy of human knee flexion/extension angle (7.87 degrees absolute root mean square error (RMSE)), hip flexion/extension angle (3.70 degrees relative RMSE), and hip abduction/adduction angle (4.56 degrees relative RMSE) during walking are similar to current state-of-the-art self-calibrating IMU methods that use magnetometers. Larger errors of hip internal/external rotation angle (6.27 degrees relative RMSE) are driven by IMU heading drift characteristic of magnetometer-free approaches and non-hinge kinematics of the hip during gait, amongst other error sources. One of these sources of error, soft tissue perturbations during gait, is explored further in the context of knee angle estimation and it was observed that the IMU method may overestimate the angle during stance and underestimate the angle during swing. The presented method and results provide a novel combination of observability considerations, heuristic correction methods, and validation techniques to magnetic-blind, kinematic-only IMU-based skeletal pose estimation during human tasks with degenerate kinematics (e.g., straight line walking).
引用
收藏
页数:16
相关论文
共 50 条
  • [1] IMU-based ambulatory walking speed estimation in constrained treadmill and overground walking
    Yang, Shuozhi
    Li, Qingguo
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (03) : 313 - 322
  • [2] Body-Worn IMU Human Skeletal Pose Estimation Using a Factor Graph-Based Optimization Framework
    McGrath, Timothy
    Stirling, Leia
    SENSORS, 2020, 20 (23) : 1 - 29
  • [3] Gaussian process framework for pervasive estimation of swimming velocity with body-worn IMU
    Dadashi, F.
    Millet, G. P.
    Aminian, K.
    ELECTRONICS LETTERS, 2013, 49 (01) : 44 - 45
  • [4] IMU-based full-body pose estimation for construction machines using kinematics modeling
    Tang, Jingyuan
    Luo, Han
    Chen, Weiwei
    Wong, Peter Kok-Yiu
    Cheng, Jack C. P.
    AUTOMATION IN CONSTRUCTION, 2022, 138
  • [5] IMU-based Smart Knee Pad for Walking Distance and Stride Count Measurement
    Wang, Teng-Chia
    Chang, Yan-Ping
    Chen, Chun-Jui
    Lee, Yun-Ju
    Lin, Chia-Chun
    Chen, Yung-Chih
    Wang, Chun-Yao
    PROCEEDINGS OF THE TWENTYFIRST INTERNATIONAL SYMPOSIUM ON QUALITY ELECTRONIC DESIGN (ISQED 2020), 2020, : 173 - 178
  • [6] IMU-Based Knee Angle Estimation using an Extended Kalman Filter
    Hidalgo, Andres F.
    Lora-Millan, Julio S.
    Rocon, Eduardo
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 570 - 573
  • [7] Oxygen cost during treadmill walking with hip and knee immobilised
    Elsworth, Charlotte
    Dawes, Helen
    Collett, Johnny
    Howells, Ken
    Ramsbottom, Roger
    Izadi, Hooshang
    Sackley, Cath
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2006, 5 (04) : 640 - 645
  • [8] IMU-based knee flexion, abduction and internal rotation estimation during drop landing and cutting tasks
    Fan, Bingfei
    Xia, Haisheng
    Xu, Junkai
    Li, Qingguo
    Shull, Peter B.
    JOURNAL OF BIOMECHANICS, 2021, 124
  • [9] IMU-Based Estimation of the Knee Contact Force using Artificial Neural Networks
    Zangene, Alireza Rezaie
    Azar, Ramila Abedi
    Naserpour, Hamidreza
    Nasab, Seyyed Hamed Hosseini
    2022 29TH NATIONAL AND 7TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2022, : 81 - 86
  • [10] IMU-Based Human Ground Reaction Force Estimation Method
    Xian, Haolan
    Zhang, Yuanwen
    Xiong, Jingfeng
    Wei, Wei
    Chen, Xinxing
    Fu, Chenglong
    Leng, Yuquan
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2024, PT VI, 2025, 15206 : 416 - 427