Thin-section CT in the examination of cervical disc herniation - A prospective study with 1-mm axial and helical images

被引:0
|
作者
Ilkko, E
Lahde, S
Heiskari, M
机构
[1] UNIV OULU, CENT HOSP, DEPT DIAGNOST RADIOL, SF-90220 OULU, FINLAND
[2] UNIV OULU, CENT HOSP, DEPT NEUROSURG, SF-90220 OULU, FINLAND
关键词
cervical spine; intervertebral disc herniation; CT; MR; myelography;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of the investigation was to determine whether thin-section high-resolution CT imaging could replace MR imaging and/or myelography in preoperative evaluation of radiculopathy and/or myelopathy. Material and Methods: A total of 120 patients, referred for cervical myelography (n = 107) or MR imaging (n = 13), were further examined with 1-mm non-contrast CT of the suspected disc space, including at least the next cephalic and caudal interspaces. Thirty-seven patients underwent Cloward's operation, at which 32 were found to have disc herniation. Results: The sensitivities of CT (n = 37), myelography (n = 29), and MR imaging (n = 8) were 66%, 84%, and 86%, respectively. The corresponding figures for false-positives were 8%, 10%, and 13%. Artefacts caused by wide shoulders in the 1-mm CT images were estimated to have contributed to a false-negative finding in 8 cases. The remaining 3 false-negatives were retrospectively considered evaluation errors. The true-positive CT findings usually presented with a local disc bulge measuring over 80 HU in density. Local ligamentous hypertrophy presented an indistinguishable finding in 3 cases, yielding false-positive CT findings. Conclusion: Conventional thin-section CT is considered a usable alternative for the evaluation of suspected cervical disc herniations in selected patients. Stocky patients with wide shoulders and a short neck are not suitable candidates, even when new generation equipment is available.
引用
收藏
页码:148 / 152
页数:5
相关论文
共 32 条
  • [31] Commercially Available Computer-Aided Detection System for Pulmonary Nodules on Thin-Section Images Using 64 Detectors-Row CT: Preliminary Study of 48 Cases
    Yanagawa, Masahiro
    Honda, Osamu
    Yoshida, Shigeyuki
    Ono, Yusuke
    Inoue, Atsuo
    Daimon, Tadahisa
    Sumikawa, Hiromitsu
    Mihara, Naoki
    Johkoh, Takeshi
    Tomiyama, Noriyuki
    Nakamura, Hironobu
    [J]. ACADEMIC RADIOLOGY, 2009, 16 (08) : 924 - 933
  • [32] Contribution of thin-slice (1mm) axial proton density MR images for identification and classification of meniscal tears: correlative study with arthroscopy
    Gokalp, G.
    Nas, O. F.
    Demirag, B.
    Yazici, Z.
    Savci, G.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018): : E871 - E878