Assessment of the gain transfer function of phosphors for application in medical imaging radiation detectors

被引:15
|
作者
Cavouras, D
Kandarakis, I
Maris, T
Panayiotakis, GS
Nomicos, CD
机构
[1] TEI Athens, Dept Med Instrumentat Technol, Athens 12210, Greece
[2] Univ Crete, Sch Med, Univ Hosp, Dept Radiol, Heraklion, Greece
[3] Univ Patras, Sch Med, Dept Phys Med, Patras 26500, Greece
[4] TEI Athens, Dept Elect, Athens 12210, Greece
关键词
phosphors; X-ray luminescence; MTF; spectral compatibility;
D O I
10.1016/S0720-048X(99)00106-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: to study various phosphors used in detectors of medical imaging systems by the gain transfer function (GTF), defined in terms of X-ray luminescence efficiency, light spectrum and modulation transfer function. Materials and methods: four phosphor materials, La2O2S:Tb, Y2O2S:Tb, Y2O2S:Eu and Y2O3:Eu were used in the form of fluorescent layers prepared in the laboratory. The GTF was determined at 30 kVp and 80 kVp X-ray tube voltages for various phosphor coating weights. Results: La2O2S:Tb, which was the highest density and effective atomic number phosphor used, was found to exhibit the best GTF performance at 80 kVp. At 30 kVp, the yttrium based phosphors were found of increased performance. This is mainly due to the proximity of the X-ray energy to the K-absorption edge of yttrium at 17 keV. Europium activated phosphors were found to perform very well when combined with the red sensitive film and the silicon photodiode. Conclusion: The GTF may be a useful method for comparing and selecting phosphor materials for use in various medical imaging applications. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [41] Phosphor material evaluation for use in medical imaging radiation detectors by the noise-equivalent-quanta (NEQ) method
    I. Kandarakis
    D. Cavouras
    C.D. Nomicos
    G.S. Panayiotakis
    Applied Physics B, 1999, 68 : 1121 - 1124
  • [42] Evolving Medical Imaging Techniques for the Assessment of Delayed Graft Function: A Narrative Review
    Hysi, Eno
    Kaur, Harmandeep
    Young, Ann
    CANADIAN JOURNAL OF KIDNEY HEALTH AND DISEASE, 2021, 8
  • [43] Assessment of Radiation Dose in Medical Imaging and Interventional Radiology Procedures for Patient and Staff Safety
    Matsubara, Kosuke
    DIAGNOSTICS, 2021, 11 (06)
  • [45] PARALLEL APPLICATION OF BLOCK-ITERATIVE METHODS IN MEDICAL IMAGING AND RADIATION-THERAPY
    CENSOR, Y
    MATHEMATICAL PROGRAMMING, 1988, 42 (02) : 307 - 325
  • [46] Assessing the validity of modulation transfer function evaluation techniques with application to small area and scanned digital detectors
    Price, B. D.
    Esbrand, C. J.
    Olivo, A.
    Gibson, A. P.
    Hebden, J. C.
    Speller, R. D.
    Royle, G. J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (11):
  • [47] MODULATION TRANSFER-FUNCTION ASSESSMENT FOR SAMPLED IMAGING-SYSTEMS - A GENERALIZATION OF THE LINE SPREAD FUNCTION
    PRIMOT, J
    GIRARD, M
    CHAMBON, M
    JOURNAL OF MODERN OPTICS, 1994, 41 (07) : 1301 - 1306
  • [48] New Application of Scintillator ZnSe(Te) in Scintielelectronic Detectors for Detection of Neutrons, Medical Imaging, Explosive Detection and NDT
    Ryzhikov, Volodymir D.
    Opolonin, Oleksandr D.
    Fedorov, Alexander G.
    Lysetska, Olena K.
    Kostioukevitch, Sergey A.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS X, 2008, 7079
  • [49] Dynamic magnetic resonance imaging in the assessment of chronic medical nephropathies with impaired renal function
    L. Dalla-Palma
    G. Panzetta
    R. S. Pozzi-Mucelli
    G. Galli
    M. Cova
    S. Meduri
    European Radiology, 2000, 10 : 280 - 286
  • [50] Dynamic magnetic resonance imaging in the assessment of chronic medical nephropathies with impaired renal function
    Dalla-Palma, L
    Panzetta, G
    Pozzi-Mucelli, RS
    Galli, G
    Cova, M
    Meduri, S
    EUROPEAN RADIOLOGY, 2000, 10 (02) : 280 - 286