Clinical workflow for MR-only simulation and planning in prostate

被引:82
|
作者
Tyagi, Neelam [1 ]
Fontenla, Sandra [1 ]
Zelefsky, Michael [2 ]
Chong-Ton, Marcia [2 ]
Ostergren, Kyle [3 ]
Shah, Niral [1 ]
Warner, Lizette [4 ]
Kadbi, Mo [4 ]
Mechalakos, Jim [1 ]
Hunt, Margie [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, 1275 York Ave, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, 1275 York Ave, New York, NY 10065 USA
[3] MIM Software Inc, Cleveland, OH 44122 USA
[4] Philips Healthcare, 595 Milner Rd, Cleveland, OH 44143 USA
来源
RADIATION ONCOLOGY | 2017年 / 12卷
关键词
Synthetic CT; MRCAT; Clinical workflow; Prostate cancer; RADIATION-THERAPY; CANCER; CT; MULTIOBSERVER; RADIOTHERAPY; ACCURACY; STANDARD; IMAGES; SPACER;
D O I
10.1186/s13014-017-0854-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To describe the details and experience of implementing a MR-only workflow in the clinic for simulation and planning of prostate cancer patients. Methods: Forty-eight prostate cancer patients from June 2016 -Dec 2016 receiving external beam radiotherapy were scheduled to undergo MR-only simulation. MR images were acquired for contouring (T2w axial, coronal, sagittal), synthetic-CT generation (3D FFE-based) and fiducial identification (3D bFFE-based). The total acquisition time was 25 min. Syn-CT was generated at the console using commercial software called MRCAT. As part of acceptance testing of the MRCAT package, external laser positioning system QA (< 2 mm) and geometric fidelity QA (< 2 mm within 50 cm LR and 30 cm AP) were performed and baseline values were set. Our current combined CT + MR simulation process was modified to accommodate a MRCAT-based MR-only simulation workflow. An automated step-by-step process using a MIMTM workflow was created for contouring on the MR images. Patient setup for treatment was achieved by matching the MRCAT DRRs with the orthogonal KV radiographs based on either fiducial ROIs or bones. 3-D CBCTs were acquired and compared with the MR/syn-CT to assess the rectum and bladder filling compared to simulation conditions. Results: Forty-two patients successfully underwent MR-only simulation and met all of our institutional dosimetric objectives that were developed based on a CT + MR-based workflow. The remaining six patients either had a hip prosthesis or their large body size fell outside of the geometric fidelity QA criteria and thus they were not candidates for MR-only simulation. A total time saving of similar to 15 min was achieved with MR-based simulation as compared to CT + MR-based simulation. An automated and organized MIM workflow made contouring on MR much easier, quicker and more accurate compared with combined CT + MR images because the temporal variations in normal structure was minimal. 2D and 3D treatment setup localization based on bones/fiducials using a MRCAT reference image was successfully achieved for all cases. Conclusions: MR-only simulation and planning with equivalent or superior target delineation, planning and treatment setup localization accuracy is feasible in a clinical setting. Future work will focus on implementing a robust 3D isotropic acquisition for contouring.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Development of a realistic phantom for MR-only treatment planning in the brain
    Chugh, Brige
    Soliman, Abraam
    Lee, Young
    Lau, Justin Y. C.
    Tseng, Chia-Lin
    Sahgal, Arjun
    Stanisz, Greg
    Lau, Angus
    MEDICAL PHYSICS, 2017, 44 (08) : 4383 - 4383
  • [42] The rationale for MR-only delineation and planning: retrospective CT-MR registration and target volume analysis for prostate radiotherapy
    Ilamurugu, Arivarasan
    Chandrasekaran, Anu Radha
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (03) : 265 - 272
  • [43] A safe clinical introduction of MR-only workflow in cone-beam CT based palliative spine radiotherapy
    Hofmeijer, Dominique H.
    Jeene, Paul M.
    Kierkels, Roel G. J.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S5528 - S5529
  • [44] Magnetic Resonance Imaging only Workflow for Radiotherapy Simulation and Planning in Prostate Cancer
    Kerkmeijer, L. G. W.
    Maspero, M.
    Meijer, G. J.
    van Zyp, J. R. N. van der Voort
    de Boer, C. J.
    van den Berg, C. A. T.
    CLINICAL ONCOLOGY, 2018, 30 (11) : 692 - 701
  • [45] MR-only treatment preparation
    Nella, Francesca
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S69 - S70
  • [46] End-To-End Phantom Evaluation for Transition From MR/CT Combined to MR-Only Workflow
    Cunningham, J. M.
    Glide-Hurst, C.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [47] Verification imaging in prostate MR-only radiotherapy: Are fiducial markers necessary?
    Brooks-Pearson, R. L.
    Pearson, R. A.
    O'Connor, L.
    Skehan, K.
    Redding, D.
    Wilkins, E.
    Taylor, S.
    Wyatt, J. J.
    RADIOGRAPHY, 2025, 31 (01) : 333 - 340
  • [48] CT synthesis with deep learning for MR-only radiotherap planning: a review
    Roh, Junghyun
    Ryu, Dongmin
    Lee, Jimin
    BIOMEDICAL ENGINEERING LETTERS, 2024, 14 (06) : 1259 - 1278
  • [49] Dosimetric and volumetric evaluation of MR-only planning for radiotherapy of rectal cancer
    Vieira, S.
    Pares, O.
    Loucao, N.
    Stroom, J.
    Santiago, I.
    Greco, C.
    Matos, C.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1025 - S1025
  • [50] CycleSeg: Simultaneous synthetic CT generation and unsupervised segmentation for MR-only radiotherapy treatment planning of prostate cancer
    Luu, Huan Minh
    Yoo, Gyu Sang
    Park, Won
    Park, Sung-Hong
    MEDICAL PHYSICS, 2024, 51 (06) : 4365 - 4379