Clinical workflow for MR-only simulation and planning in prostate

被引:82
|
作者
Tyagi, Neelam [1 ]
Fontenla, Sandra [1 ]
Zelefsky, Michael [2 ]
Chong-Ton, Marcia [2 ]
Ostergren, Kyle [3 ]
Shah, Niral [1 ]
Warner, Lizette [4 ]
Kadbi, Mo [4 ]
Mechalakos, Jim [1 ]
Hunt, Margie [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, 1275 York Ave, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, 1275 York Ave, New York, NY 10065 USA
[3] MIM Software Inc, Cleveland, OH 44122 USA
[4] Philips Healthcare, 595 Milner Rd, Cleveland, OH 44143 USA
来源
RADIATION ONCOLOGY | 2017年 / 12卷
关键词
Synthetic CT; MRCAT; Clinical workflow; Prostate cancer; RADIATION-THERAPY; CANCER; CT; MULTIOBSERVER; RADIOTHERAPY; ACCURACY; STANDARD; IMAGES; SPACER;
D O I
10.1186/s13014-017-0854-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To describe the details and experience of implementing a MR-only workflow in the clinic for simulation and planning of prostate cancer patients. Methods: Forty-eight prostate cancer patients from June 2016 -Dec 2016 receiving external beam radiotherapy were scheduled to undergo MR-only simulation. MR images were acquired for contouring (T2w axial, coronal, sagittal), synthetic-CT generation (3D FFE-based) and fiducial identification (3D bFFE-based). The total acquisition time was 25 min. Syn-CT was generated at the console using commercial software called MRCAT. As part of acceptance testing of the MRCAT package, external laser positioning system QA (< 2 mm) and geometric fidelity QA (< 2 mm within 50 cm LR and 30 cm AP) were performed and baseline values were set. Our current combined CT + MR simulation process was modified to accommodate a MRCAT-based MR-only simulation workflow. An automated step-by-step process using a MIMTM workflow was created for contouring on the MR images. Patient setup for treatment was achieved by matching the MRCAT DRRs with the orthogonal KV radiographs based on either fiducial ROIs or bones. 3-D CBCTs were acquired and compared with the MR/syn-CT to assess the rectum and bladder filling compared to simulation conditions. Results: Forty-two patients successfully underwent MR-only simulation and met all of our institutional dosimetric objectives that were developed based on a CT + MR-based workflow. The remaining six patients either had a hip prosthesis or their large body size fell outside of the geometric fidelity QA criteria and thus they were not candidates for MR-only simulation. A total time saving of similar to 15 min was achieved with MR-based simulation as compared to CT + MR-based simulation. An automated and organized MIM workflow made contouring on MR much easier, quicker and more accurate compared with combined CT + MR images because the temporal variations in normal structure was minimal. 2D and 3D treatment setup localization based on bones/fiducials using a MRCAT reference image was successfully achieved for all cases. Conclusions: MR-only simulation and planning with equivalent or superior target delineation, planning and treatment setup localization accuracy is feasible in a clinical setting. Future work will focus on implementing a robust 3D isotropic acquisition for contouring.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Clinical workflow for MR-only simulation and planning in prostate
    Neelam Tyagi
    Sandra Fontenla
    Michael Zelefsky
    Marcia Chong-Ton
    Kyle Ostergren
    Niral Shah
    Lizette Warner
    Mo Kadbi
    Jim Mechalakos
    Margie Hunt
    Radiation Oncology, 12
  • [2] Clinical commissioning of MR-Only Prostate treatment planning workflow
    Bolard, G.
    Bulling, S.
    Hejira, N.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 852 - 852
  • [3] Clinical Commissioning of MR-Only Prostate Treatment Planning Workflow
    Bolard, G.
    Bulling, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3721 - 3721
  • [4] Clinical Workflow for MR-Only Simulation and Planning in Prostate Cancer Patients Undergoing External Beam Radiotherapy (EBRT)
    Tyagi, N.
    Fontenla, S.
    Zelefsky, M.
    Chong-ton, M.
    Ostergren, K.
    Shah, N.
    Warner, L.
    Kadbi, M.
    Mechalakos, J.
    Hunt, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3047 - 3047
  • [5] Prostate Contour Variability in An MR-Only Prostate SBRT Workflow
    Davidson, M.
    Shaaer, A.
    Stewart, J.
    Vesprini, D.
    Detsky, J.
    Loblaw, A.
    Chu, W.
    Chung, H.
    Liu, S.
    Shahi, J.
    Wronski, M.
    Ruschin, M.
    McCann, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E649 - E650
  • [6] The Feasibility of MR-Only IMRT Planning for Prostate Anatomy
    Vaitheeswaran, R.
    Sivaramakrishnan, K. R.
    Kumar, Prashant
    Gattamaneni, Raja
    Kumar, Girish
    MEDICAL PHYSICS, 2016, 43 (06) : 3443 - 3443
  • [7] Routine QA of an MR-only workflow
    Frantzen-Steneker, M.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S12 - S12
  • [8] Clinical outcome for Glioblastoma treated with photon radiotherapy in an MR-only workflow
    Hedman, Mattias
    Gubanski, Michael
    Giovenco, Marcela
    Navarro, Fernanda Villegas
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S749 - S751
  • [9] IMPROVING SPATIAL ACCURACY IN EXTERNAL RADIOTHERAPY OF THE PROSTATE - INVESTIGATION OF A MR-ONLY WORKFLOW
    Nyholm, T.
    Karlsson, M.
    Karlsson, M.
    Zackrisson, B.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S181 - S181
  • [10] Clinical implementation of MR-only prostate radiotherapy excluding CT
    Persson, E.
    Ambolt, P.
    Gustafsson, C.
    Back, S.
    Engelholm, S.
    Gunnlaugsson, A.
    Olsson, L. E.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1211 - S1212