Ground-based coronagraphy: Performance of a four-quadrant phase mask

被引:0
|
作者
Puga, E [1 ]
Feldt, M [1 ]
Henning, T [1 ]
Kley, EB [1 ]
Costa, JB [1 ]
Bizenberger, P [1 ]
Hippler, S [1 ]
机构
[1] Max Planck Inst Astron, D-69117 Heidelberg, Germany
关键词
coronagraphic techniques; phase mask;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Detection of faint companions near bright stars requires the usage of high dynamic range instrumentation. The four quadrant phase mask is a quite efficient nulling device for the light of on-axis stars as shown by simulations. (1,2) We conducted a test of the true performance of this concept starting with the manufacturing of the optical element, continuing with the installation in the telescope and the usage of the Adaptive Optics system (essential for this coronagraphic tool). A four quadrant phase mask was installed in the 3.5m telescope on Calar Alto and several tests with both an artificial source and natural stars were conducted. Tests in order to detect faint companions around HD 140913, TRN 1 and HD 161797 were successful for the last target and also, although almost serendipitously, in the case of HD144004. The main limitations found for the phase mask cancelling effect at relatively low Strehl ratios (16%-63%) were the residual tip-tilt of our system and the control of placement of the mask in the optical train.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 50 条
  • [1] Multi-stage four-quadrant phase mask: achromatic coronagraph for space-based and ground-based telescopes
    Galicher, R.
    Baudoz, P.
    Baudrand, J.
    [J]. ASTRONOMY & ASTROPHYSICS, 2011, 530
  • [2] Achromatic four-quadrant phase mask (FQPM) coronagraphy using natural beam splitter phase shifts
    Bloemhof, EE
    [J]. OPTICS EXPRESS, 2005, 13 (25): : 10055 - 10060
  • [3] Unbalanced nulling interferometer with four-quadrant phase mask
    Kobayashi, Takuji
    Nishikawa, Jun
    Tanaka, Yosuke
    Kurokawa, Takashi
    Kashiwagi, Ken
    Murakami, Naoshi
    Baba, Naoshi
    Hashimoto, Nobuyuki
    [J]. 22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [4] The four-quadrant phase mask coronagraph. III. Laboratory performance
    Riaud, P
    Boccaletti, A
    Baudrand, J
    Rouan, D
    [J]. PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2003, 115 (808) : 712 - 719
  • [5] Development and characterization of Four-Quadrant Phase Mask coronagraph (FQPM)
    Bonafous, M.
    Galicher, R.
    Baudoz, P.
    Firminy, J.
    Boussaha, F.
    [J]. ADVANCES IN OPTICAL AND MECHANICAL TECHNOLOGIES FOR TELESCOPES AND INSTRUMENTATION II, 2016, 9912
  • [6] Four-quadrant phase mask coronagraph with a Jacquinot-Lyot stop
    Murakami, N.
    Uemura, R.
    Baba, N.
    Sato, Y.
    Nishikawa, J.
    Tamura, M.
    [J]. ASTROPHYSICAL JOURNAL, 2008, 677 (02): : 1425 - 1432
  • [7] Pupil-remapping mirrors for a four-quadrant phase mask coronagraph
    Murakami, N
    Baba, N
    [J]. PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2005, 117 (829) : 295 - 299
  • [8] Recent experimental results with the four-quadrant phase-mask coronograph
    Riaud, P
    Boccaletti, A
    Baudrand, J
    Reess, JM
    Rouan, D
    [J]. TOWARDS OTHER EARTHS: DARWIN/TPF AND THE SEARCH FOR EXTRASOLAR TERRESTRIAL PLANETS, PROCEEDINGS, 2003, 539 : 361 - 366
  • [9] Estimated performances of a four-quadrant phase mask coronagraph for planet detection
    Rouan, D
    Boccaletti, A
    Riaud, P
    Baudrand, J
    [J]. HIGH-CONTRAST IMAGING FOR EXO-PLANET DETECTION, 2003, 4860 : 192 - 199
  • [10] Joint Optimization of Apodizer and Lyot stop for Coronagraph with Four-Quadrant Phase Mask
    Ge, Rui
    Zhao, Hui
    Li, Chuang
    Fan, Xue-wu
    Yu, Cong-cong
    [J]. SPACE OPTICS, TELESCOPES, AND INSTRUMENTATION (AOPC 2019), 2019, 11341