The four-quadrant phase mask coronagraph. III. Laboratory performance

被引:53
|
作者
Riaud, P [1 ]
Boccaletti, A [1 ]
Baudrand, J [1 ]
Rouan, D [1 ]
机构
[1] Observ Paris, LESIA, F-92195 Meudon, France
关键词
D O I
10.1086/375385
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We report a laboratory experiment to assess the performance and limitations of the four-quadrant phase mask coronagraph we proposed 2 years ago. A total flux rejection factor of 4400 was reached using off-the-shelf optical components. The peak intensity of the Airy pattern is correspondingly reduced by a factor of 44,000 with a stability of a few hours. In this paper, we discuss implications of this excellent result regarding the next generation of instruments for extrasolar planet detection.
引用
收藏
页码:712 / 719
页数:8
相关论文
共 50 条
  • [1] The four-quadrant phase-mask coronagraph. II. Simulations
    Riaud, P
    Boccaletti, A
    Rouan, D
    Lemarquis, F
    Labeyrie, A
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2001, 113 (787) : 1145 - 1154
  • [2] The four-quadrant phase-mask coronagraph.: I.: Principle
    Rouan, D
    Riaud, P
    Boccaletti, A
    Clénet, Y
    Labeyrie, A
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2000, 112 (777) : 1479 - 1486
  • [3] The four-quadrant phase mask coronagraph. IV. First light at the Very Large Telescope
    Boccaletti, A
    Riaud, P
    Baudoz, P
    Baudrand, J
    Rouan, D
    Gratadour, D
    Lacombe, F
    Lagrange, AM
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2004, 116 (825) : 1061 - 1071
  • [4] Development and characterization of Four-Quadrant Phase Mask coronagraph (FQPM)
    Bonafous, M.
    Galicher, R.
    Baudoz, P.
    Firminy, J.
    Boussaha, F.
    ADVANCES IN OPTICAL AND MECHANICAL TECHNOLOGIES FOR TELESCOPES AND INSTRUMENTATION II, 2016, 9912
  • [5] The four-quadrant phase-mask coronagraph: white light laboratory results with an achromatic device
    Mawet, D
    Riaud, P
    Baudrand, J
    Baudoz, P
    Boccaletti, A
    Dupuis, O
    Rouan, D
    ASTRONOMY & ASTROPHYSICS, 2006, 448 (02) : 801 - 808
  • [6] The four-quadrant phase-mask coronagraph: White light laboratory results with an achromatic device
    Mawet, D.
    Riaud, P.
    Baudrand, J.
    Baudoz, P.
    Boccaletti, A.
    Dupuis, O.
    Rouan, D.
    Astronomy and Astrophysics, 2006, 448 (02): : 801 - 808
  • [7] Pupil-remapping mirrors for a four-quadrant phase mask coronagraph
    Murakami, N
    Baba, N
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2005, 117 (829) : 295 - 299
  • [8] Estimated performances of a four-quadrant phase mask coronagraph for planet detection
    Rouan, D
    Boccaletti, A
    Riaud, P
    Baudrand, J
    HIGH-CONTRAST IMAGING FOR EXO-PLANET DETECTION, 2003, 4860 : 192 - 199
  • [9] Four-quadrant phase mask coronagraph with a Jacquinot-Lyot stop
    Murakami, N.
    Uemura, R.
    Baba, N.
    Sato, Y.
    Nishikawa, J.
    Tamura, M.
    ASTROPHYSICAL JOURNAL, 2008, 677 (02): : 1425 - 1432
  • [10] Joint Optimization of Apodizer and Lyot stop for Coronagraph with Four-Quadrant Phase Mask
    Ge, Rui
    Zhao, Hui
    Li, Chuang
    Fan, Xue-wu
    Yu, Cong-cong
    SPACE OPTICS, TELESCOPES, AND INSTRUMENTATION (AOPC 2019), 2019, 11341